Campbell Hausfeld WG3020 Maintenance, Consumer and Wear Parts, Installation, CO2

Page 6

Wire Feed Arc Welder

Operation (Continued)

4.Connect the work clamp to the work piece or workbench (if metal). Make sure the contact is secure. Avoid surfaces with paint, varnish, corrosion, or non-metallic materials.

5.Position the Heat Selector on the front panel to the desired setting. See application decal inside door of wire feed compartment for proper heat settings.

NOTE: These settings are general guidelines only. Heat setting may vary according to welding conditions and materials.

6.

Rotate the Wire Speed Control to

 

setting number 5 to start with, then

 

adjust as needed after test weld.

7.

Plug the input cord into a proper

 

voltage receptacle with proper

 

ARGON OR

 

ARGON MIX

INSTALLATION

Adapter

Cap

OR

CO2

 

INSTALLATION

Figure 6 - Hookup

 

circuit capacity (See Chart under

circuit requirements on page 1).

8. Switch the welder ON.

9. Verify that the wire is extended

1/4” from the contact tip. If not,

squeeze the trigger to feed

additional wire, release the trigger,

and cut wire to proper length.

10. Position the wire feed gun near the

work piece, lower the welding

helmet by nodding the head, or

Do not operate this

! WARNING welding machine

with cracked or missing insulation on welding cables, wire feed gun, or power cord.

Every 3 months:

1.Replace any unreadable safety labels on the welder.

2.Use compressed air to blow all dust and lint from the ventilation openings.

Torch Neck

Contact Tip

Nozzle

Figure 7 - Nozzle and Contact Tip

position the hand shield, and

squeeze the gun trigger. Adjust heat

setting and wire speed as needed.

11. When finished welding, turn welder

off and store properly.

Maintenance

Disconnect power

! WARNING supply and turn machine off before inspecting or servicing any components. Keep the wire compartment cover closed at all times unless the wire needs replacement.

Before every use:

1.Check condition of weld cables and immediately repair or replace any cables with damaged insulation.

2.Check condition of power cord and immediately repair or replace any cord if damaged.

3.Inspect the condition of the gun tip and nozzle. Remove any weld slag. Replace gun tip or nozzle if damaged.

3.Clean the wire groove on the drive roll. Remove wire from the feed mechanism, remove screws from the drive roll housing. Use a small wire brush to clean the drive roll. Replace if worn or damaged.

Consumer and Wear Parts

The following parts require routine maintenance:

Wire feed drive roller

Gun liner - replace if worn

Nozzle/contact tips

Wire - this welder will accept either 4” or 8” diameter spools. Welding wire is susceptible to moisture and oxidizes over time, so it is important to select a spool size that will be used within approximately 6 months. For mild steel welding, AWS ER70S6 solid wire or AWS E71T-GS flux-core wire is recommended.

Contact tips - use Campbell Hausfeld, Tweco®, and other compatible tips.

Nozzle - use Tweco® style or compatible nozzle. Use Campbell Hausfeld nozzle model WT5021 found at place of purchase of welder, or use Tweco® style nozzle (or compatible nozzle) found at local welding supply store.

www.chpower.com

6

Image 6
Contents Unpacking General SafetyDescription Circuit RequirementsWire Feed Arc Welder Installation Additional Safety StandardsAssembly Wire InstallationModel WG3020 Welding Helmet Assembly Shielding Gas InstallationOperation Consumer and Wear Parts MaintenanceInstallation CO2General Changing Wire SizesWelding Guidelines Arc Welding BasicsWire Speed Slag Removal FLUX-CORE Wire onlyTravel Speed Supply Cable Replacement Troubleshooting Chart Welder Troubleshooting Chart WeldsLimited 5-3-1 Warranty What is not covered under this warrantyWG3020 Wiring Diagram For Replacement Parts, call Replacement Parts List Model WG3020 Description Part Number QtyGlossary of Welding Terms Shielded Metal Arc WeldingWire Feed Arc Welder WG3020 Branchement de polarité Fixer Commande de réglage deSélecteurs de chaleur Pour Pistolet d’alimentation en filGénéralités Sur La Sécurité Suite 18 FrNormes DE Sécurité Additionnelles National Electrical Code Code Électrique National19 Fr Installation de Fils MontageModèle WG3020 Installation de Gaz Protecteur Montage SuiteMontage du Casque de Soudeur Installation de Gaz Protecteur Suite Fonctionnement22 Fr Pointes DE Contact Remplacement par un fil de dimensions différentesEntretien Suite FIL D’ALUMINIUMDirectives De Soudage GénéralitésPrincipes Du Soudage a l’Arc Positions DE Soudage Enlevage DE Scorie FIL Fourré DE Flux SuelementRemarque Passes DE SoudageGuide de dépannage Soudeur Remplacement du Cordon d’AlimentationDirectives De Soudage Suite Tirer PousserGuide de dépannage Soudures Garantie Limitée27 Fr Soudeur À L’Arc Alimenté En Fil WG3020 28 FrPour pièces de rechange, composer 29 FrListe De Pièces De Rechange Modèles WG3020 30 FrSoudure À L’arc Au Chalumeau Lexique de Termes de SoudageSoudure À L’Arc Fourré de Flux Soudure À L’Arc Au Métal Enrobé32 Fr Para desempacar DescripciónMedidas de Seguridad Requerimientos eléctricosContinuación 34 SpInstalación Medidas DE Seguridad Adicionales35 Sp Ensamblaje Modelo WG3020Instalacion del alambre Ensamblaje del Casco FuncionamientoInstalacion Para MantenimientoPiezas Consumibles o Que se Desagstan 38 SpBoquillas DE Contacto Cambio de tamaños de alambreBobina Alambre DE AluminioInstrucciones para Soldar Tecnicas Basicas Para Soldar Con ArcosInstrucciones para Soldar Continuación Hale Empuje Diagnostico Diagóstico de Averías-SoldadoraPara Reemplazar el Cable 42 SpDiagóstico de Averías-Soldadura Garantía Limitada43 Sp Soldadora Con Arco Con Alambre Continuo WG3020 44 Sp45 Sp Sírvase suministrarnos la siguiente informaciónLista de Repuestos Modelos WG3020 46 SpGlosario de terminología usada por soldadores Soldar con Arcos de Metal GaseosoSoldar con Arcos de Tungsteno Notas