HP Pay per use (PPU) manual Introduction, Overview

Page 15

1 Introduction

1.1 Overview

The Utility Meter is a component in the setup of a Pay per use (PPU) or Utility Ready Storage (URS) solution. PPU and URS are part of HP's Utility Pricing Solutions (UPS) program. In this program, customers are charged according to usage of the PPU and URS computing resources (servers and storage) under a UPS contract.

For more information on this program, see the Metered Capacity link on the Utility Pricing Web page: http:/ /h71028.www7.hp.com/enterprise/cache/308072-0-0-0-121.html.

For version 8.13 of the HP Utility Meter software, the HP “Utility Meter” is a combination of both an HP server running HP-UX and the HP Utility Meter software. For the list of compatible Utility Meter HP-UX servers, see Recommended Hardware.

The Utility Meter is usually located at the customer site along with the customer’s UPS computing resources. The Utility Meter only needs to connect to a UPS computing resource through the TCP/IP protocol. There is no geographical limit as to where the UPS computing resources are located.

The main task of the Utility Meter is to receive usage information from UPS computing resources that are under an HP UPS Utility contract (such as HP servers and HP storage devices) and send the usage data in a secure way to HP. The Utility Meter tracks the usage of:

Enterprise servers – A specific set of both HP Integrity servers and HP 9000 servers are supported in the PPU Utility program. The supported PPU enterprise servers are partitionable and each PPU partition must be configured to be metered by the Utility Meter. In version 8.13 there are now two ways to monitor a server: via the PPU Agent software or (new to version 8.13) by adding a PPU WBEM Partition/Server to the meter.

For PPU Agent devices, communication can be configured between the PPU partition and the Utility Meter through the appropriate PPU Agent software command on each PPU partition. Refer to the PPU User's Guide (see Related Documentation) for details of the PPU Agent software commands. The PPU Agent software sends PPU usage data to the Utility Meter, then the Utility Meter sends the data securely to HP.

For a PPU WBEM Partition/Server, communication can be configured by adding a PPU WBEM Partition/Server to the Utility Meter via the Utility Meter GUI.

Storage devices – Specific EVA and XP storage devices are supported in the Utility Ready Storage (URS) program. Both the Command View server and its disk arrays, which are to be metered by the Utility Meter, must be configured using the Utility Meter software's graphical user interface (GUI). Usage data is obtained in the following ways:

XP: Usage data is retrieved through the HP StorageWorks XP Command View Advanced Edition Command Line Interface (CLI) software that is installed on the Utility Meter. The CLI software communicates with the HP StorageWorks XP Command View Advanced Edition server that is on a separate system.

EVA: Usage data is retrieved through the HP Systems Insight Manager (HP SIM) database on the Utility Meter. The HP SIM database receives its data from the HP StorageWorks Command View EVA server through the SMI-Sservice that is on a separate system.

The Utility Meter software sends the URS usage data securely from the Utility Meter to HP.

NOTE: A single Utility Meter can meter up to 1,000 metered instances (server partitions plus storage devices).

See Flow of Metered Usage Data for details of the usage-data flow from the UPS computing resources to HP.

The Utility Meter sends PPU and URS usage data to HP securely over the Internet through HTTPS or email on a daily basis. Data sent to HP is encrypted before transmitting.

The Utility billing engine processes usage data from the Utility database once per month and billing information is sent to the customer.

1.1 Overview 15

Image 15
Contents HP Utility Meter Users Guide for version Page Table of Contents Troubleshooting the Utility Meter Performing Utility Meter TasksVerifying Utility Meter Operation Site Preparation Form for Utility Ready Storage Site Preparation Form for Pay Per UsePage List of Figures Page Common Utility Meter Tasks Recommended Minimum Hardware List of TablesPage Document Organization About This DocumentIntended Audience Publishing HistoryCommon Utility Meter Tasks HP Encourages Your Comments Locating This GuideTypographic Conventions Related DocumentsPage Overview IntroductionIntroduction Swapping Utility Meter Hardware What is New for VersionReminder of What was New in Version Recommended HardwareEVA Supported URS PlatformsSupported PPU Platforms SoftwareUtility Meter Software Dependencies Utility Meter Software Back UpUtility Meter Directory Structure Installation and Support Services Data Sent to HPMissing Usage Reports Data Transport Methods Ordering Utility Pricing Solutions Web PortalIntroduction Installing and Configuring the Utility Meter Software Before Going to the Customer Site Skills RequiredInstalling the HP Systems Insight Manager Software Configuring the HP-UX System ParametersInstalling the Utility Meter Software # /usr/sbin/swinstall -s hostnamepathname T2805AA \ Usr/sbin/swinstall -s path-to-depotT2805AAUsr/sbin/swinstall -s path-to-depotT5462A # /usr/sbin/swinstall# /opt/meter/bin/monitor status Configuring the Utility Meter ParametersCompleting the Utility Meter Software Installation # /usr/sbin/shutdown -r# /usr/bin/X11/xclock # export DISPLAY=10.x.x.x0.0# /opt/meter/bin/umGUI Utility Meter GUI Main Window # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start # /opt/meter/bin/SetupCLI URS XP Only Installing the XP CV AE CLI SoftwareAvoiding CLI Conflicts Email Masquerading# /opt/meter/sbin/sendmail-config Automated email MasqueradingManual email Masquerading Verifying email Masquerading Try esmtp umeter@hostname.corp.example Try esmtp umeter@localhostUpgrading the Utility Meter Software to Version Configuring PPU Partitions and URS DevicesCompleting the Utility Meter Installation and Configuration Verifying the Utility Meter OperationInstalling and Configuring the Utility Meter Software Information Performing Utility Meter TasksUtility Meter GUI Main Window should appear Starting the Utility Meter GUIStarting the Utility Meter GUI Main Window Main Window Performing Utility Meter Tasks Utility Meter Help Information Utility Meter Configure Tasks Network Configuration Utility Meter Software Parameters To Change the Utility Meter Software Parameters # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Copy the Meters Configuration Load the Meter’s ConfigurationStorage Devices Namespace Configuration Port Protocol https Utility Meter Devices Tasks 10 Devices Tab Configure a Device Add DeviceAdd an EVA Device Performing Utility Meter Tasks Add an XP Device Performing Utility Meter Tasks Add a PPU Wbem Partition/Server 13 Add Device Dialog Box for PPU Wbem Partition/Server Change a non-URS Disk Array to URS Modify DevicePerforming Utility Meter Tasks View Device Change PPU Wbem Partition/Server Configuration ParametersRemove Device 17 View Device Error WindowDiscover Physical Devices Utility Meter Diagnose Tasks 20 Diagnose Tab Meter Connection StatusVerify Device Connection Device ConnectionDevice Connection PPU Wbem Partition/Server Page Transfer Data through CD Task # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Transfer Data through CD Task Performing Utility Meter Tasks Verifying the Utility Meter Software is Operational # /usr/bin/grep Error /etc/rc.logVerifying Utility Meter Operation Verifying the Utility Meter Hardware is OperationalVerifying the Correct Version of HP SIM is Installed Verifying the CIM Server Software Is Operational# /usr/sbin/swlist /usr/bin/grep -i sim # /usr/bin/kill -9 processid # /usr/bin/ps -ef /usr/bin/grep cim /usr/bin/grep -v grep# /opt/meter/bin/ConnectionTest Verifying Connectivity from the Utility Meter to HPData Transfer by Https # /opt/wbem/bin/osinfo# /usr/bin/mailq Data Transfer by emailVerifying the Utility Meter Data Transport Method Verify PPU Wbem Partition/Server ConfigurationVerify PPU Agent Configuration Verifying the Data Acquisition Server is RunningTest Connection from PPU Partition to UPS Web Portal Test Connection from PPU Agent to Utility MeterUPS Portal Welcome Page Verifying a Storage Device Verifying a Device is Configured in the Utility MeterVerifying the Connection from the Utility Meter to HP Verifying a Device is Connected to the Utility Meter# /usr/bin/rm /tmp/cli.out Device Manager CLI version# /usr/sbin/shutdown -R -H Troubleshooting the Utility MeterTroubleshooting Overview # /usr/bin/hostnameUtility Meter Software Troubleshooting a Storage Device Troubleshooting a DeviceVerifying the Correct Version of XP CV AE CLI is Installed Troubleshooting a Wbem DeviceFixing a Disconnected Device with Red Box Osinfo -hhostname -s-ulogin# /opt/meter/bin/monitor stop Table A-1 PPU Site Preparation Form Site Preparation Form for Pay Per UseNetworking details on the PPU Wbem Partition/Server Table B-1 PPU Networking Details Form Site Preparation Form for Utility Ready StorageNetworking Details for the Command View XP AE Server Networking Details for the Command View EVA Server 100 Cpuid Data Fields Sent from the Utility Meter to HPData Fields Sent from the Utility Meter to HP CLI Glossary104 Index Index