HP Pay per use (PPU) manual Skills Required, Before Going to the Customer Site

Page 26

4.Install the Utility Meter software. For information about this installation, see Installing the Utility Meter Software. Note that a reboot of the Utility Meter system and verification of the Utility Meter processes and services are required.

5.Configure the Utility Meter software parameters by using the Utility Meter application GUI. For more information about the Utility Meter configuration, see Configuring the Utility Meter Parameters.

6.If there are Utility Ready Storage (URS) XP devices that need to be metered, install the version 6.0 (or later) HP StorageWorks XP Command View Advanced Edition Command Line Interface (CLI) software. For more information about this type of installation, see URS XP Only – Installing the XP CV AE CLI Software.

7.If there are URS XP or EVA devices that need to be metered by the Utility Meter, configure the devices in the Utility Meter GUI. For more information about this type of configuration, see Utility Meter Devices Tasks.

8.If there are Pay per use (PPU) server partitions that need to be metered by the Utility Meter, configure every PPU partition by adding the partitions as a PPU WBEM Partition/Server in the Utility Meter GUI or configure the partitions with the appropriate PPU Agent software command. For more information about configuring partitions with PPU Agent software, see Related Documentation for a link to the PPU User's Guide.

9.Verify the Utility Meter operation (see Chapter 4: “Verifying Utility Meter Operation”).

2.2 Skills Required

The Utility Meter software installation and configuration requires the following skills:

HP-UX operating system concepts, commands, and configuration

PPU Agent software commands and configuration (for PPU installations that use PPU Agent software)

CIM commands such as cimserver and cimprovider (for PPU installations that use PPU WBEM Partition/Server)

Disk array configuration and Command View product experience (for URS installations)

sendmail experience and understanding of detailed information in the appropriate (HP–UX 11i v2, or 11i v3) HP-UX Mailing Services Administrator's Guide at: http://docs.hp.com.

2.3Before Going to the Customer Site

For initial Utility Meter installation and configuration, make sure you have the following items before going to the customer site:

The Utility Meter Site Preparation Form must have all values filled out. For details, see Appendix A “Site Preparation Form for Pay Per Use” or Appendix B “Site Preparation Form for Utility Ready Storage”. The preparation form contains the networking and Utility Meter information you need to complete the Utility Meter installation. You must work with the customer to complete this preparation form.

IMPORTANT: HP recommends that the IP address and hostname of the Utility Meter are entered into the customer's DNS tables prior to installing and configuring the Utility Meter software. The propagation of the Utility Meter's IP address and hostname into DNS may take some time to occur.

The HP-UX server that is used as the Utility Meter system needs a keyboard, mouse, and video (capable of running X Windows applications) only for Utility Meter installation and configuration. After installation, the keyboard, mouse, and video are not required. You must ensure that the customer can provide (or was included in the order) a keyboard, mouse, and video (capable of running X Windows applications) or you will need to provide them yourself. (Customers have many keyboard, mouse, and video alternatives, including: direct connection, KVM switch, Web, remote, and other methods.)

The Utility Meter system's password for the user root. You can obtain this password from the customer.

Access to the Utility Meter software (either HP product T2805AA for PPU or T5462A for URS):

26 Installing and Configuring the Utility Meter Software

Image 26
Contents HP Utility Meter Users Guide for version Page Table of Contents Verifying Utility Meter Operation Troubleshooting the Utility MeterPerforming Utility Meter Tasks Site Preparation Form for Pay Per Use Site Preparation Form for Utility Ready StoragePage List of Figures Page List of Tables Common Utility Meter Tasks Recommended Minimum HardwarePage Publishing History About This DocumentIntended Audience Document OrganizationCommon Utility Meter Tasks Related Documents Locating This GuideTypographic Conventions HP Encourages Your CommentsPage Introduction OverviewIntroduction Recommended Hardware What is New for VersionReminder of What was New in Version Swapping Utility Meter HardwareSupported URS Platforms EVASoftware Supported PPU PlatformsUtility Meter Directory Structure Utility Meter Software DependenciesUtility Meter Software Back Up Missing Usage Reports Installation and Support ServicesData Sent to HP Data Transport Methods Utility Pricing Solutions Web Portal OrderingIntroduction Installing and Configuring the Utility Meter Software Skills Required Before Going to the Customer SiteConfiguring the HP-UX System Parameters Installing the HP Systems Insight Manager SoftwareInstalling the Utility Meter Software # /usr/sbin/swinstall Usr/sbin/swinstall -s path-to-depotT2805AAUsr/sbin/swinstall -s path-to-depotT5462A # /usr/sbin/swinstall -s hostnamepathname T2805AA \# /usr/sbin/shutdown -r Configuring the Utility Meter ParametersCompleting the Utility Meter Software Installation # /opt/meter/bin/monitor status# /opt/meter/bin/umGUI # /usr/bin/X11/xclock# export DISPLAY=10.x.x.x0.0 Utility Meter GUI Main Window # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start URS XP Only Installing the XP CV AE CLI Software # /opt/meter/bin/SetupCLIEmail Masquerading Avoiding CLI ConflictsManual email Masquerading # /opt/meter/sbin/sendmail-configAutomated email Masquerading Verifying email Masquerading Try esmtp umeter@localhost Try esmtp umeter@hostname.corp.exampleVerifying the Utility Meter Operation Configuring PPU Partitions and URS DevicesCompleting the Utility Meter Installation and Configuration Upgrading the Utility Meter Software to VersionInstalling and Configuring the Utility Meter Software Performing Utility Meter Tasks InformationStarting the Utility Meter GUI Utility Meter GUI Main Window should appearStarting the Utility Meter GUI Main Window Main Window Performing Utility Meter Tasks Utility Meter Help Information Utility Meter Configure Tasks Network Configuration Utility Meter Software Parameters To Change the Utility Meter Software Parameters # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Storage Devices Namespace Configuration Copy the Meters ConfigurationLoad the Meter’s Configuration Port Protocol https Utility Meter Devices Tasks Configure a Device Add Device 10 Devices TabAdd an EVA Device Performing Utility Meter Tasks Add an XP Device Performing Utility Meter Tasks Add a PPU Wbem Partition/Server 13 Add Device Dialog Box for PPU Wbem Partition/Server Modify Device Change a non-URS Disk Array to URSPerforming Utility Meter Tasks Change PPU Wbem Partition/Server Configuration Parameters View Device17 View Device Error Window Remove DeviceDiscover Physical Devices Utility Meter Diagnose Tasks Meter Connection Status 20 Diagnose TabDevice Connection Verify Device ConnectionDevice Connection PPU Wbem Partition/Server Page Transfer Data through CD Task # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Transfer Data through CD Task Performing Utility Meter Tasks Verifying the Utility Meter Hardware is Operational # /usr/bin/grep Error /etc/rc.logVerifying Utility Meter Operation Verifying the Utility Meter Software is Operational# /usr/sbin/swlist /usr/bin/grep -i sim Verifying the Correct Version of HP SIM is InstalledVerifying the CIM Server Software Is Operational # /usr/bin/ps -ef /usr/bin/grep cim /usr/bin/grep -v grep # /usr/bin/kill -9 processid# /opt/wbem/bin/osinfo Verifying Connectivity from the Utility Meter to HPData Transfer by Https # /opt/meter/bin/ConnectionTestData Transfer by email # /usr/bin/mailqVerifying the Data Acquisition Server is Running Verify PPU Wbem Partition/Server ConfigurationVerify PPU Agent Configuration Verifying the Utility Meter Data Transport MethodTest Connection from PPU Agent to Utility Meter Test Connection from PPU Partition to UPS Web PortalUPS Portal Welcome Page Verifying a Device is Configured in the Utility Meter Verifying a Storage DeviceVerifying a Device is Connected to the Utility Meter Verifying the Connection from the Utility Meter to HPDevice Manager CLI version # /usr/bin/rm /tmp/cli.out# /usr/bin/hostname Troubleshooting the Utility MeterTroubleshooting Overview # /usr/sbin/shutdown -R -HUtility Meter Software Troubleshooting a Device Troubleshooting a Storage DeviceTroubleshooting a Wbem Device Verifying the Correct Version of XP CV AE CLI is InstalledOsinfo -hhostname -s-ulogin Fixing a Disconnected Device with Red Box# /opt/meter/bin/monitor stop Site Preparation Form for Pay Per Use Table A-1 PPU Site Preparation FormNetworking details on the PPU Wbem Partition/Server Site Preparation Form for Utility Ready Storage Table B-1 PPU Networking Details FormNetworking Details for the Command View XP AE Server Networking Details for the Command View EVA Server 100 Data Fields Sent from the Utility Meter to HP CpuidData Fields Sent from the Utility Meter to HP Glossary CLI104 Index Index