Access to the version 5.1 HP Systems Insight Manager (HP SIM) software, which is available from the HP Software Depot (http://www.software.hp.com—search for “HP SIM 5.x”). Alternatively, you can download and save the HP SIM 5.1 software's depot file from the HP Software Depot to writable media, such as a CD or flash drive.

This guide – print a copy of it for your reference. Note that this guide is available from the HP Technical documentation Web site. See Locating This Guide for details.

2.4Configuring the HP-UX System Parameters

In order for the Utility Meter to connect to the network, you must configure HP-UX networking parameters. The values for these parameters are contained in the Utility Meter Site Preparation Form, which is filled out by the customer. Follow the procedures in this section to configure the HP-UX network parameters for the initial setup or if you need to make changes to the network information after the initial setup.

IMPORTANT: Make sure that port 5989 is not blocked or used by any other software. If there is a firewall between the Utility Meter and a PPU partition, then port 5989 must be open. Note that this is true for both PPU WBEM partitions and PPU partitions running PPU Agent software.

During the initial Utility Meter system (hardware) startup, a system and network configuration dialog is displayed on the system console. Use the Utility Meter Site Preparation Form to provide answers to the questions asked.

This dialog can be re-executed at any time by running the /sbin/set_parms command as root.

set_parms(1m) is described in chapter 3, task 5 of the HP-UX installation manual. You can also get set_parms information by executing this command on an HP-UX 11i v2, or 11i v3 system: man set_parms. After system initialization, set_parms can be called with the following parameters to alter the configuration:

hostname – sets the system hostname and domain name. The hostname specified needs to be resolvable on the public Internet.

timezone – sets the system time-zone information.

date_time – set the system date and time interactively.

root_passwd – set/change the password for the system's root user.

ip_address – sets the system's Internet Protocol address, netmask, and default route (gateway address.)

Any site-specific configuration of the network should be executed after the initial setup of HP-UX is complete. For example, ensure that the speed setting of the Utility Meter's LAN interface matches the speed setting of the Ethernet switch in use.

IMPORTANT: After changing the HP-UX system parameters, the Utility Meter software parameters must be reconfigured to match the HP-UX system parameters that were changed. See Configuring the Utility Meter Parameters.

2.5 Installing the HP Systems Insight Manager Software

CAUTION: The HP Systems Insight Manager (HP SIM) version 5.1 software must be installed prior to the Utility Meter software installation.

The HP SIM version 5.1 software must be installed on the Utility Meter. For details of the HP SIM version 5.1 software installation, see the HP Systems Insight Manager 5.1 Installation and Configuration Guide for HP-UXlocated at: http://docs.hp.com/en/netsys.html#HP Systems Insight Manager.

Basically, you use swinstall to install HP SIM 5.1 on the Utility Meter. Be sure to select all subpackages in the swinstall GUI or specify \* on the command line.

2.4 Configuring the HP-UX System Parameters 27

Image 27
Contents HP Utility Meter Users Guide for version Page Table of Contents Troubleshooting the Utility Meter Performing Utility Meter TasksVerifying Utility Meter Operation Site Preparation Form for Utility Ready Storage Site Preparation Form for Pay Per UsePage List of Figures Page Common Utility Meter Tasks Recommended Minimum Hardware List of TablesPage Document Organization About This DocumentIntended Audience Publishing HistoryCommon Utility Meter Tasks HP Encourages Your Comments Locating This GuideTypographic Conventions Related DocumentsPage Overview IntroductionIntroduction Swapping Utility Meter Hardware What is New for VersionReminder of What was New in Version Recommended HardwareEVA Supported URS PlatformsSupported PPU Platforms SoftwareUtility Meter Software Dependencies Utility Meter Software Back UpUtility Meter Directory Structure Installation and Support Services Data Sent to HPMissing Usage Reports Data Transport Methods Ordering Utility Pricing Solutions Web PortalIntroduction Installing and Configuring the Utility Meter Software Before Going to the Customer Site Skills RequiredInstalling the HP Systems Insight Manager Software Configuring the HP-UX System ParametersInstalling the Utility Meter Software # /usr/sbin/swinstall -s hostnamepathname T2805AA \ Usr/sbin/swinstall -s path-to-depotT2805AAUsr/sbin/swinstall -s path-to-depotT5462A # /usr/sbin/swinstall# /opt/meter/bin/monitor status Configuring the Utility Meter ParametersCompleting the Utility Meter Software Installation # /usr/sbin/shutdown -r# /usr/bin/X11/xclock # export DISPLAY=10.x.x.x0.0# /opt/meter/bin/umGUI Utility Meter GUI Main Window # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start # /opt/meter/bin/SetupCLI URS XP Only Installing the XP CV AE CLI SoftwareAvoiding CLI Conflicts Email Masquerading# /opt/meter/sbin/sendmail-config Automated email MasqueradingManual email Masquerading Verifying email Masquerading Try esmtp umeter@hostname.corp.example Try esmtp umeter@localhostUpgrading the Utility Meter Software to Version Configuring PPU Partitions and URS DevicesCompleting the Utility Meter Installation and Configuration Verifying the Utility Meter OperationInstalling and Configuring the Utility Meter Software Information Performing Utility Meter TasksUtility Meter GUI Main Window should appear Starting the Utility Meter GUIStarting the Utility Meter GUI Main Window Main Window Performing Utility Meter Tasks Utility Meter Help Information Utility Meter Configure Tasks Network Configuration Utility Meter Software Parameters To Change the Utility Meter Software Parameters # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Copy the Meters Configuration Load the Meter’s ConfigurationStorage Devices Namespace Configuration Port Protocol https Utility Meter Devices Tasks 10 Devices Tab Configure a Device Add DeviceAdd an EVA Device Performing Utility Meter Tasks Add an XP Device Performing Utility Meter Tasks Add a PPU Wbem Partition/Server 13 Add Device Dialog Box for PPU Wbem Partition/Server Change a non-URS Disk Array to URS Modify DevicePerforming Utility Meter Tasks View Device Change PPU Wbem Partition/Server Configuration ParametersRemove Device 17 View Device Error WindowDiscover Physical Devices Utility Meter Diagnose Tasks 20 Diagnose Tab Meter Connection StatusVerify Device Connection Device ConnectionDevice Connection PPU Wbem Partition/Server Page Transfer Data through CD Task # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Transfer Data through CD Task Performing Utility Meter Tasks Verifying the Utility Meter Software is Operational # /usr/bin/grep Error /etc/rc.logVerifying Utility Meter Operation Verifying the Utility Meter Hardware is OperationalVerifying the Correct Version of HP SIM is Installed Verifying the CIM Server Software Is Operational# /usr/sbin/swlist /usr/bin/grep -i sim # /usr/bin/kill -9 processid # /usr/bin/ps -ef /usr/bin/grep cim /usr/bin/grep -v grep# /opt/meter/bin/ConnectionTest Verifying Connectivity from the Utility Meter to HPData Transfer by Https # /opt/wbem/bin/osinfo# /usr/bin/mailq Data Transfer by emailVerifying the Utility Meter Data Transport Method Verify PPU Wbem Partition/Server ConfigurationVerify PPU Agent Configuration Verifying the Data Acquisition Server is RunningTest Connection from PPU Partition to UPS Web Portal Test Connection from PPU Agent to Utility MeterUPS Portal Welcome Page Verifying a Storage Device Verifying a Device is Configured in the Utility MeterVerifying the Connection from the Utility Meter to HP Verifying a Device is Connected to the Utility Meter# /usr/bin/rm /tmp/cli.out Device Manager CLI version# /usr/sbin/shutdown -R -H Troubleshooting the Utility MeterTroubleshooting Overview # /usr/bin/hostnameUtility Meter Software Troubleshooting a Storage Device Troubleshooting a DeviceVerifying the Correct Version of XP CV AE CLI is Installed Troubleshooting a Wbem DeviceFixing a Disconnected Device with Red Box Osinfo -hhostname -s-ulogin# /opt/meter/bin/monitor stop Table A-1 PPU Site Preparation Form Site Preparation Form for Pay Per UseNetworking details on the PPU Wbem Partition/Server Table B-1 PPU Networking Details Form Site Preparation Form for Utility Ready StorageNetworking Details for the Command View XP AE Server Networking Details for the Command View EVA Server 100 Cpuid Data Fields Sent from the Utility Meter to HPData Fields Sent from the Utility Meter to HP CLI Glossary104 Index Index