4.9.4 XP Only – Verifying the Correct Version of XP CV AE CLI is Installed
Utility Ready Storage (URS) installations that have XP devices configured in the Utility Meter must have version
6.0(or later) of the HP StorageWorks XP Command View Advanced Edition Command Line Interface (CLI) software installed on the Utility Meter.
NOTE: The XP CV AE CLI is not required for URS installations that have only EVA devices configured in the Utility Meter.
Perform the following procedure on the Utility Meter to verify that version 6.0 (or later) of the CLI software is installed on the Utility Meter for URS XP installations. On the Utility Meter:
1.Log in as root.
2.Execute the following commands:
#/opt/CLI/hdvmcli.sh > /tmp/cli.out 2>&1
#/usr/bin/grep
You should output that is similar to the following displayed:
Device Manager CLI version "6.0.0-00"
If you do not see version 6.0 (or later) of the XP CV AE CLI displayed, install the CLI software by following the instructions in URS XP Only – Installing the XP CV AE CLI Software.
If you see the correct version of the CLI displayed, then you have successfully verified that the correct version of the CLI is installed and no further action is necessary. However, you can clean up the Utility Meter /tmp directory with the following command:
# /usr/bin/rm /tmp/cli.out
88 Verifying Utility Meter Operation