HP Pay per use (PPU) manual What is New for Version, Reminder of What was New in Version

Page 17

1.2 What is New for Version 8.13

Version 8.13 of the Utility Meter software is the fifth release of the Utility Meter 8.x software. Version 8.13 includes the following changes:

Multi-Tiering billing support for XP storage whereby billing can be based on the different disk types in the array. Previously all XP disks were charged the same amount.

A change in how usage is reported for THP on an XP storage device. Now usage is reported for the amount used whereas previously usage was reported for the amount set aside in THP pools.

8.13 will be the first release that supports XP20000 and EVA4400.

1.3Reminder of What was New in Version 8.12.03

Version 8.12.03 of the Utility Meter software was the fourth release of the Utility Meter 8.x software. Version 8.12.03 included the following changes:

An alternative method for metering HP-UX servers was made available. Previously, this could only be accomplished by installing and configuring the PPU Agent software on each HP-UX partition. For Version 8.12.03 HP-UX partitions could be metered by installing the standard CIM/WBEM software, usually done when the OS was installed.

Metering of Linux partitions (SUSE and RHEL) was possible via the CIM/WBEM software installed on the metered server.

Version 8.12.03 was the first release that did not support HP-UX 11i v1 for the meter operating system, however, the meter continues to measure servers using HP-UX 11i v1.

1.4Recommended Hardware

CAUTION: The hardware used to run the Utility Meter 8.13 software must be used exclusively for the Utility Meter software application. That is, no other software applications or services are allowed on the Utility Meter hardware.

The Utility Meter 8.13 software runs on many HP Integrity servers and HP 9000 servers; however, HP recommends the following minimum Utility Meter hardware:

Table 1-1 Recommended Minimum Hardware

Server Model

Operating System

Memory

Storage

Peripheral

Networking

rp3440

HP-UX 11i v2, or

2 GB

2 x 72 GB in RAID

DVD RW

One Ethernet port

 

HP-UX 11i v3

 

11

 

 

rx2620 or rx3600

HP-UX 11i v2 or

2 GB

2 x 72 GB in RAID

DVD RW

One Ethernet port

 

HP-UX 11i v3

 

1 1

 

 

1To increase redundancy, the two disks are preferably placed in a RAID 1 configuration using a hardware RAID controller, such as the Smart Array Controller 6402 (HP product number A9890A).

1.4.1Swapping Utility Meter Hardware

If you want to change the current Utility Meter hardware from one HP-UX server to another, you need to contact an HP services representative to perform this task.

1.4.2 Disk Space Requirements

Depending on whether Pay per use (PPU) servers or Utility Ready Storage (URS), or both, are metered by the Utility Meter, the /opt and /var directories must have enough space allocated to accommodate the Utility Meter's usage reports.

The Utility Meter's /opt directory is a fixed size and must have a minimum of 2.5 GB of disk space allocated.

1.2 What is New for Version 8.13 17

Image 17
Contents HP Utility Meter Users Guide for version Page Table of Contents Verifying Utility Meter Operation Troubleshooting the Utility MeterPerforming Utility Meter Tasks Site Preparation Form for Utility Ready Storage Site Preparation Form for Pay Per UsePage List of Figures Page Common Utility Meter Tasks Recommended Minimum Hardware List of TablesPage Intended Audience About This DocumentPublishing History Document OrganizationCommon Utility Meter Tasks Typographic Conventions Locating This GuideRelated Documents HP Encourages Your CommentsPage Overview IntroductionIntroduction Reminder of What was New in Version What is New for VersionRecommended Hardware Swapping Utility Meter HardwareEVA Supported URS PlatformsSupported PPU Platforms SoftwareUtility Meter Directory Structure Utility Meter Software DependenciesUtility Meter Software Back Up Missing Usage Reports Installation and Support ServicesData Sent to HP Data Transport Methods Ordering Utility Pricing Solutions Web PortalIntroduction Installing and Configuring the Utility Meter Software Before Going to the Customer Site Skills RequiredInstalling the HP Systems Insight Manager Software Configuring the HP-UX System ParametersInstalling the Utility Meter Software Usr/sbin/swinstall -s path-to-depotT5462A Usr/sbin/swinstall -s path-to-depotT2805AA# /usr/sbin/swinstall # /usr/sbin/swinstall -s hostnamepathname T2805AA \Completing the Utility Meter Software Installation Configuring the Utility Meter Parameters# /usr/sbin/shutdown -r # /opt/meter/bin/monitor status# /opt/meter/bin/umGUI # /usr/bin/X11/xclock# export DISPLAY=10.x.x.x0.0 Utility Meter GUI Main Window # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start # /opt/meter/bin/SetupCLI URS XP Only Installing the XP CV AE CLI SoftwareAvoiding CLI Conflicts Email MasqueradingManual email Masquerading # /opt/meter/sbin/sendmail-configAutomated email Masquerading Verifying email Masquerading Try esmtp umeter@hostname.corp.example Try esmtp umeter@localhostCompleting the Utility Meter Installation and Configuration Configuring PPU Partitions and URS DevicesVerifying the Utility Meter Operation Upgrading the Utility Meter Software to VersionInstalling and Configuring the Utility Meter Software Information Performing Utility Meter TasksUtility Meter GUI Main Window should appear Starting the Utility Meter GUIStarting the Utility Meter GUI Main Window Main Window Performing Utility Meter Tasks Utility Meter Help Information Utility Meter Configure Tasks Network Configuration Utility Meter Software Parameters To Change the Utility Meter Software Parameters # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Storage Devices Namespace Configuration Copy the Meters ConfigurationLoad the Meter’s Configuration Port Protocol https Utility Meter Devices Tasks 10 Devices Tab Configure a Device Add DeviceAdd an EVA Device Performing Utility Meter Tasks Add an XP Device Performing Utility Meter Tasks Add a PPU Wbem Partition/Server 13 Add Device Dialog Box for PPU Wbem Partition/Server Change a non-URS Disk Array to URS Modify DevicePerforming Utility Meter Tasks View Device Change PPU Wbem Partition/Server Configuration ParametersRemove Device 17 View Device Error WindowDiscover Physical Devices Utility Meter Diagnose Tasks 20 Diagnose Tab Meter Connection StatusVerify Device Connection Device ConnectionDevice Connection PPU Wbem Partition/Server Page Transfer Data through CD Task # /opt/meter/bin/monitor stop # /opt/meter/bin/monitor start Transfer Data through CD Task Performing Utility Meter Tasks Verifying Utility Meter Operation # /usr/bin/grep Error /etc/rc.logVerifying the Utility Meter Hardware is Operational Verifying the Utility Meter Software is Operational# /usr/sbin/swlist /usr/bin/grep -i sim Verifying the Correct Version of HP SIM is InstalledVerifying the CIM Server Software Is Operational # /usr/bin/kill -9 processid # /usr/bin/ps -ef /usr/bin/grep cim /usr/bin/grep -v grepData Transfer by Https Verifying Connectivity from the Utility Meter to HP# /opt/wbem/bin/osinfo # /opt/meter/bin/ConnectionTest# /usr/bin/mailq Data Transfer by emailVerify PPU Agent Configuration Verify PPU Wbem Partition/Server ConfigurationVerifying the Data Acquisition Server is Running Verifying the Utility Meter Data Transport MethodTest Connection from PPU Partition to UPS Web Portal Test Connection from PPU Agent to Utility MeterUPS Portal Welcome Page Verifying a Storage Device Verifying a Device is Configured in the Utility MeterVerifying the Connection from the Utility Meter to HP Verifying a Device is Connected to the Utility Meter# /usr/bin/rm /tmp/cli.out Device Manager CLI versionTroubleshooting Overview Troubleshooting the Utility Meter# /usr/bin/hostname # /usr/sbin/shutdown -R -HUtility Meter Software Troubleshooting a Storage Device Troubleshooting a DeviceVerifying the Correct Version of XP CV AE CLI is Installed Troubleshooting a Wbem DeviceFixing a Disconnected Device with Red Box Osinfo -hhostname -s-ulogin# /opt/meter/bin/monitor stop Table A-1 PPU Site Preparation Form Site Preparation Form for Pay Per UseNetworking details on the PPU Wbem Partition/Server Table B-1 PPU Networking Details Form Site Preparation Form for Utility Ready StorageNetworking Details for the Command View XP AE Server Networking Details for the Command View EVA Server 100 Cpuid Data Fields Sent from the Utility Meter to HPData Fields Sent from the Utility Meter to HP CLI Glossary104 Index Index