HP OneView for VMware vCenter/Operations Manager/Log Insight Checking the initialization status

Page 10

servers. After you configure storage arrays and management servers, configure the VMware VASA provider (optional).

For information about initialization and the Storage Administrator Portal, see “Checking the initialization status” (page 10) and “About the Storage Administrator Portal” (page 10).

For configuration instructions, see “Configuring arrays and management servers” (page 11) and “Configuring the VMware VASA provider” (page 19).

Checking the initialization status

During the initialization process, data is gathered from the vCenter environment. You cannot use the Storage Module for vCenter until initialization is complete and the HP storage arrays are configured in the vSphere Client.

To see the initialization status:

1.Log in to the vSphere Client.

When you start the vSphere Client GUI for the first time after the Storage Module for vCenter is installed, you might see a security warning related to the SSL certificate. HP recommends installing a valid SSL certificate. For more information about generating and uploading a certificate signing request, see “Configuring the Server Module for vCenter” (page 7). Until you install a valid SSL certificate, select the Install this certificate and do not display any security warnings for <server hostname> check box, and then click Ignore.

When you access the HP Insight Software tab in the vSphere Client GUI, you might see security warnings related to the website security certificate. To prevent these warnings from appearing in the future, click View Certificate, and then follow the instructions to import the certificate.

2.Select a host or cluster, and then click the HP Insight Software tab.

3.Click a Storage Information link in the HP Management pane.

If the initialization process is not complete, the Storage Module for vCenter displays a status message. See Figure 1 (page 10).

Figure 1 Initialization status

4.To determine if initialization is still in progress, click the Check Again button.

5.When the initialization process is complete, proceed to “Configuring arrays and management servers” (page 11).

About the Storage Administrator Portal

The Storage Administrator Portal enables you to configure arrays and management servers for management by the Storage Module for vCenter.

For arrays that support provisioning, use the Storage Administrator Portal to assign access permissions to storage pools. See Figure 2 (page 11). You can use the vSphere Client to perform storage provisioning operations such as adding a new datastore, deleting or expanding an existing datastore, creating new VMs, or cloning existing VMs on storage pools that are set to Full Access. For more information, see “Provisioning storage” (page 51).

10 Configuring Insight Control for vCenter

Image 10
Contents HP Insight Control for VMware vCenter Server Acknowledgements Contents Provisioning storage TroubleshootingViewing hardware alert notifications Support and other resources Firewall port requirements Glossary IndexOverview Configuring Insight Control for vCenter Configuring the Server Module for vCenterAutomatic association Onboard Administrator Single Sign-OnAssociating the VMware host to iLO Manual associationConfiguring the Storage Module for vCenter Using the Insight Control for vCenter PropertiesAbout the Storage Administrator Portal Checking the initialization statusConfiguring arrays and management servers Setting storage pool accessAdding HP P6000 Command View management servers For instructions, see Manually refreshing the dataAdding HP P6000 EVA arrays Adding HP P4000 arrays Adding HP MSA2000 G2 arraysAdding HP P2000 G3 MSA Systems Adding HP XP arrays Adding HP P9000 arraysViewing arrays and management servers Modifying configured arrays and management servers Removing an array or management server Modify management server or array type page appearsConfiguring the VMware Vasa provider Adding a CA-signed certificateConfiguring Insight Control for vCenter Accessing Insight Control for vCenter Using Insight Control for vCenterHP Management pane overview Using the Server Module for vCenter OverviewSetting the power cost for a cluster Changing Server Management propertiesManaging clusters HP SIMViewing infrastructure information for a cluster Viewing power management information for a clusterViewing and updating firmware on clustered servers Managing servers Manage Smart ComponentsViewing server configuration information Viewing server power/thermal informationViewing server networking information Virtual Connect Network Diagram Viewing and updating firmware on selected serversLaunching into HP tools Using the Insight Control Deployment WizardViewing logs Using the Storage Module for vCenter PrerequisitesHP Insight Software tab Refreshing Storage Module for vCenter data Manually refreshing the dataChanging the automatic data refresh settings Canceling a data refreshRestarting a data refresh Customizing Storage Module for vCenter tables Storage Module for vCenter tabsViewing storage information for a host Viewing VM or datastore overview informationViewing summary information Viewing storage information for a cluster Viewing detailed informationViewing storage information for a datastore Viewing storage information for a VM Viewing related VM informationViewing related datastore information Viewing related host information Viewing detailed storage informationViewing storage disks Storage disksViewing virtual disks Virtual Disks tabViewing HBAs Viewing hostsViewing paths Paths tab Using Insight Control for vCenter Viewing replications Viewing all VMs associated with a host or clusterView All tab Using the Storage Module for vCenter Using Insight Control for vCenter Accessing the storage tools Provisioning storageHosts Changing the default location for all P6000 EVA arraysAdding a new datastore ClustersAdd Datastores Specify Storage window Storage Array capacity Add Datastores Review and Validate window after validation Expanding a datastore Add Datastores Summary windowDeleting a datastore Expand Datastore windowDeleting an unassigned volume Deleting a volumeCreating a VM from a template Create Virtual Machines Specify VMs windowProvisioning storage Create Virtual Machines Specify Names window Provisioning storage Cloning a VM Create Virtual Machines Summary windowClone Virtual Machine Clone Parameters window Clone Virtual Machine Specify New Names window Provisioning storage Clone Virtual Machine Summary window Insight Control for vCenter events Onboard Administrator eventsViewing hardware alert notifications VCenter Server event category infoVCenter Server event category warning VCenter Server event category error Alarms HP Snmp agent and HP CIM provider eventsAlarm icon Viewing the log files TroubleshootingTroubleshooting Insight Control for vCenter HP Insight Software tab not available in vSphere ClientVCenter service terminates during startup Slow response in the vSphere ClientInternet Explorer script error buttons.0.0 is null Stale or corrupt cache or cookies results in GUI anomalies Troubleshooting the Server Module for vCenterError Communicating with iLO at VM host Server summary data is not displayed for hostTroubleshooting the Server Module for vCenter HP SIM auto-login fails from Insight Control for vCenter Cost Advantage field not showing valuesTroubleshooting the Storage Module for vCenter Firmware inventory information is not shownStorage Administrator Portal login credentials Refresh takes a long time to completeGUI RMI connection exception in Storage Overview P9000 virtual disk information missing from Storage OverviewJBoss exceptions occur when running Vasa provider service Storage information cannot be exportedCannot configure datastore block size Support and other resources How to contact HPInformation to collect before contacting HP Related information HP authorized resellersDocumentation feedback DocumentsFirewall port requirements Insight Control for vCenter firewall portsGlossary CLISSO Index P2000 G3 MSA errors troubleshooting, 84 P2000 G3 MSA System Index