HP NuDAQ I-9111DG/HR manual 9111Initial, 9111DO, ++ Dos, ++ Windows, Visual Basic Windows

Page 48

5.3_9111_Initial

@Description

This function is used to initialize PCI_9111. Every PCI_9111 card has to be initialized by this function before calling other functions.

@ Syntax

C/C++ (DOS)

U16 _9111_Initial (U16 *existCards, PCI_INFO *info)

C/C++ (Windows 95)

U16 W_9111_Initial (U16 *existCards, PCI_INFO *info)

Visual Basic (Windows 95)

W_9111_Initial (existCards As Integer, info As PCI_INFO) As Integer

@ Argument

existCards: number of existing PCI-9111 cards

pciInfo:

relative information of the PCI-9111 cards

@ Return Code

 

 

ERR_NoError

ERR_BoardNoInit

ERR_PCIBiosNotExist

5.4_9111_DO

@Description

This function is used to write data to digital output port. There are 16 digital output channels on PCI_9111.

@ Syntax

C/C++ (DOS)

U16 _9111_DO (U16 cardNo, U16 DOData)

C/C++ (Windows 95)

U16 W_9111_DO (U16 cardNo, U16 DOData)

Visual Basic (Windows 95)

W_9111_DO (ByVal cardNo As Integer, ByVal DOData As Integer) As Integer

@ Argument

 

cardNo:

The card number of PCI-9111 card initialized

DOData:

The value will be written to digital output port

@Return Code

ERR_NoError

38 C/C++ Library

Image 48
Contents NuDAQ Trademarks Getting service from Adlink QuestionsPage Features Applications Specifications Software Supporting B l e o f C o n t e n t sPCI PnP Registers Address Map Libraries Installation Programming Guide Hardware Interrupt Clear RegisterConversion Interrupt ControlTable of Contents ∙ What do you need VR Assignment Adjustment 9111utilHow to Use This Guide Page Features IntroductionSpecifications ApplicationsUnipolar 0~10V Bipolar -10V~+10V Software Supporting Programming LibraryPCIS-LVIEW LabVIEW Driver PCIS-VEE HP-VEE DriverDAQBenchTM ActiveX Controls DASYLabTM PROPCIS-ICL InControlTM Driver PCIS-OPC OPC ServerInstallation ∙ Software Installation GuideWhat You Have UnpackingPCI-9111s Layout PCB Layout of the PCI-9111Hardware Installation Outline Jumper DescriptionsDevice Installation for Windows Systems Connectors Pin Assignment∙ CN 1 Digital Signal Input DI 0 ~ ∙ CN 2 Digital Signal Output do 0 ~ ∙ CN 3 Analog Input/Output, Extended I/O, Trigger SignalsDaughter Board Connection Connect with ACLD-8125Connect with ACLD-9137 Connect with ACLD-9182Registers Format PCI PnP RegistersI/O Address Map A/D Data RegistersAddress Write Read I/O AddressA/D Channel Control Register Address Base + 0h Attribute read only Data FormatBit Address Base + 6h Attribute write only Data Format BitA/D Input Signal Range Control Register A/D Channel Read Back RegisterAddress Base + 6h Attribute read only Data Format Bit Address Base + 8h Attribute write only Data Format BitA/D Trigger Mode Control Register A/D Range and Status Read back RegisterAddress Base + 8h Attribute read only Data Format Bit Address Base + 0Ah Attribute write only Data Format BitMode Description Address Base + 0Eh Attribute write only Data Format BitAddress Base + 0Ch Attribute write only Data Format Bit 12 A/D Mode & Interrupt Control Read Back Register Hardware Interrupt Clear RegisterAddress Base + 48h Attribute write only Data Format Bit Address Base + 0Ah Attribute read only Data Format BitAddress Base + 4h Attribute write only Data Format Bit Address Base + 4h Attribute read only Data Format BitAddress Base + 2h Attribute read only Data Format 15 D/A Output Register Address Base + 2h Attribute write only Data Format BitAddress Base + 40h ~ Base + 46h Operation Theorem A/D Conversion1 A/D Conversion Procedure 2 A/D Signal Source ControlAnalog Input Signal Connection Signal Range 3 A/D Trigger Source Control4 A/D Data Transfer Modes External Trigger EITS=1, TPST=don‘t careFifo Half-Full Polling Pre-Trigger Control EOC Interrupt TransferTime 6 A/D Data Format FFFIRQ Level Setting Interrupt Control System ArchitectureDual Interrupt System Interrupt Source Control Extended Digital I/O PortD/A Conversion 44mV 88mVTimer/Counter Operation Introduction Digital Input and OutputPacer Trigger Source Pre-Trigger Counter4 I/O Address Libraries Installation ++ LibraryProgramming Guide Naming Convention Data Types9111Initial 9111DO++ DOS ++ Windows9111DOChannel 9111DI9111DIChannel 9111EDI9111EDO 10 9111EDOReadBack11 9111SetEDOFunction 12 9111DA 13 9111ADReadData14 9111ADReadDataRepeat 15 9111ADSetChannel16 9111ADGetChannel 17 9111ADSetRange Input Range Gain Gain Code18 9111ADGetRange 19 9111ADGetStatus20 9111ADSetMode 21 9111ADGetMode 22 9111INTSetReg24 9111ResetFIFO 23 9111INTGetReg25 9111ADSoftTrigger 26 9111Set825428 9111ADTimer 27 9111Get825429 9111CounterStart 30 9111CounterRead31 9111CounterStop 32 9111INTSourceControl 33 9111CLRIRQ 34 9111GetIRQChannel35 9111GetIRQStatus 36 9111ADFFHFPolling37 9111ADAquire 38 9111ADHRAquire39 9111ADINTStart 40 9111ADFFHFINTStart ++ Library ∙61 41 9111ADINTStatus 42 9111ADFFHFINTStatus43 9111ADFFHFINTRestart 44 9111ADINTStop Calibration What do you needA/D Adjustment VR AssignmentFunctions of VRs D/A Adjustment Unipolar Analog Output Bipolar Analog OutputSoftware Utility 9111utilRunning 9111util.exe System Configuration Calibration Functional Testing Function Testing Menu WindowIeeprom Product Warranty/Service