HP 8753ET manual Table of contents

Page 2

Table of contents

Definitions and test conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 System performance summaries . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Specifications and characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Measurement throughput summary . . . . . . . . . . . . . . . . . . . . . . . . .21 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Test set specifications for Option 011 . . . . . . . . . . . . . . . . . . . . . . . .22 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24

2

Image 2
Contents Specifications Table of contents Dynamic range Measurement port characteristicsDefinitions and test conditions Measurement uncertaintyMm test ports System performance summariesHP 8753ES 50-ohm systems Network analyzer HP 8753ESType-N test ports Calibration kit HP 85032B Test-port cables HP 11857DCalibration kit HP 85033D Test-port cables HP 11857D Frequency rangeCalibration kit HP 85036B Test-port cables HP 11857B HP 8753ES 75-ohm systemsNetwork analyzer Type-F test ports Calibration kit HP 85039B Test-port cables HP 11857BMeasurement port characteristics KHz to 16 MHz 100 dB MHz to 3 GHz 110 dB GHz to 6 GHz 105 dBTest port input characteristics HP 8753ES specificationsTest-port output characteristics7 CW time sweep only CharacteristicsPhase characteristics KHz to 6 GHzTest port input characteristics Option HP 8753ES Option 011 specificationsTest port output characteristics Frequency KHz to 3 GHz To -35 dBm GHz to 6 GHz To -30 dBm20 kHz CW time sweep onlyKHz to 3 GHz HP 8753ET specificationsTest-port output characteristics Option 006 300 kHz to 6 GHz±500 dB Test-port input characteristicsMagnitude characteristics ±180˚Measurement HP 8753ET/ES supplemental characteristicsGroup delay characteristics Source controlDisplay control Data accuracy enhancementData averaging Data hardcopy Trace functionsStorage System capabilitiesTime-domain Option Remote programmingTest sequences This stimulus is also used to measure low-pass devicesGeneral characteristics Options HP 85046A/B S-parameter test sets Test set specifications for OptionHP 85046A/B Specifications +20 dBm SpecificationsHP 85047A S-parameter test set +30 dBmAccessories HP 11906B 7-16 to 50-Ohm type-N adapter kit HP 85039B type-F calibration kit SpecificationsHP 85038 family of calibration kits HP 11906C 7-16 to 7-mm adapter kitVerification kits Test-port return cablesHP 85024A high-frequency probe Ohm accessory kitsRF limiter HP 8347A RF amplifier DimensionsWeight