DISPlay
The DISPlay subsystem monitors the channel state of a selected module (or card) in a switchbox. This subsystem only operates with mainframes that have a display, such as the HP 75000 Series B Mainframe (HP Model Number E1301A).
Subsystem Syntax | DISPlay  | 
  | :MONitor  | 
  | :CARD <number AUTO>  | 
  | [:STATe] <mode>  | 
  | [:STATe]?  | 
:MONitor:CARD | DISPlay:MONitor:CARD <number AUTO> selects the module in a  | |||
  | switchbox to be monitored when the monitor mode is enabled. Use the  | |||
  | DISPlay:MONitor:STATe command to enable and disable the monitor mode.  | |||
Parameters  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | Parameter Name  | Parameter Type  | Range of Values  | Default Value  | 
  | 
  | 
  | 
  | 
  | 
  | number AUTO  | numeric  | 1 - 99 or AUTO  | AUTO  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |||
Comments | ∙ Selecting a Specific Module to be Monitored: Use the | |||
  | DISPlay:MONitor:CARD command to send the card number in a  | |||
  | switchbox to be monitored.  | 
  | 
  | |
∙Selecting the Present Module to be Monitored: Use the
DISPlay:MONitor AUTO command to select the last module addressed by a switching command (e.g.,[ROUTe:]CLOSe).
∙*RST Condition: DISPlay:MONitor:CARD AUTO
Example Select Module #2 in a Switchbox for Monitoring
DISP:MON:CARD 2  | Selects module #2 in a switchbox  | 
  | to be monitored when the mode is  | 
  | enabled.  | 
Chapter 4 | HP E1368A/69A/70A Command Reference 53  |