HP E1368A Ieee 488.2 Common Commands, HP Command Module User’s Manual, or the ANSI/IEEE Standard

Page 70

IEEE 488.2 Common Commands

 

The following table lists the IEEE 488.2 Common (*) Commands that can

 

be executed by the Microwave Switch modules. The operation of some of

 

these commands is described in Chapter 3 of this manual. For more

 

information on Common Commands, refer to the HP 75000 Series B

 

Mainframe User’s Manual (HP Model Number E1300/E1301), appropriate

 

HP Command Module User’s Manual, or the ANSI/IEEE Standard

 

488.2-1987.

 

 

 

 

 

 

Command

Title

Description

 

 

 

 

 

 

*IDN?

Identification query

Returns identification string of the switchbox.

*RST

Reset

Opens all channels, and invalidates current channel list for scanning.

 

 

Sets ARM:COUN 1, TRIG:SOUR IMM, and INIT:CONT OFF.

*TST?

Self-Test

Always returns 0.

 

 

 

*OPC

Operation Complete

Sets the request for OPC flag when all pending operations have

 

 

completed. Also sets OPC bit in the Standard Event Register.

*OPC?

Operation Complete Query

Returns a 1 to the output queue when all pending operations have

 

 

completed. Used to synchronize between multiple instruments.

*WAI

Wait to Complete

Halts execution of commands and queries until the "No Operation

 

 

Pending" message is true.

 

 

 

*CLS

Clear status

Clears all Event Registers, the Request for OPC flag, and all queues

 

 

(except output queue).

*ESE<mask>

Event status enable

Used to set the bits in the Event Status Enable Register.

*ESE?

Event status enable query

Queries the current contents in the Event Status Enable Register.

*ESR?

Event status register query

Queries and clears the contents in the Standard Event Status Register.

*SRE<mask>

Service request enable

Used to set the Service Request Enable Register bits, and corresponding

 

 

Serial Poll Status Byte Register bits, to generate a service request.

*SRE?

Service request enable query

Queries the current contents in the Service Request Enable Register.

*STB?

Read status byte query

Queries the current contents in the Status Byte Register.

 

 

 

*TRG

Trigger

Triggers the switchbox to advance the scan when scan is enabled and

 

 

trigger source is TRIGger:SOURce BUS.

 

 

 

*RCL<n>

Recall saved state

Recalls previously stored Microwave Switch module configuration.

 

 

<n> (0 to 9) is the location in memory where the desired (previously

 

 

stored) set-up is located.

*SAV<n>

Save state

Stores present settings of ARM:COUNt, TRIGger:SOURce,

 

 

OUTPut[:STATe], INITiate:CONTinuous, SCAN:MODE, and

 

 

SCAN:PORT. <n> (0 to 9) is the location in memory where the current

 

 

set-up is located.

 

 

 

Note: See the HP 75000 Series B E1300/E1301 Mainframe User’s Manual or the ANSI/IEEE Standard 488.2-1987 for more information about these commands.

70 HP E1368A/69A/70A Command Reference

Chapter 4

Image 70
Contents Contents Open OPEN? Scan Scanmode SCANMODE? Cpon HP E1368A/69A/70A Modules User’s Manual Contents Certification Documentation History April According to ISO/IEC Guide 22 and ENPage Business Reply Mail Page Using This Chapter Microwave Switch DescriptionGetting Started with the HP E1368A/69A/70A Chapter Power Supply Circuit HP E1368A SwitchesProgramming the Microwave Switch Instrument DefinitionCard Numbers for Multiple-Module Switchboxes Example Reset the switchbox and close channel Initial OperationConfiguring the HP E1368A/69A/70A Modules Setting the Address Switch Logical Address SelectionSelecting the Interrupt Priority Interrupt Priority SelectionInstalling Switches on the HP E1369A Installing Switches on the ModuleChapter Configuring the HP E1368A/69A/70A Modules Microwave Switch Installation Connecting Switches External To the Module Selecting Switch Power Connecting Field Wiring Selecting Switch VoltageInstalling a Switch Or Attenuator on Module Microwave Switch/Attenuator Installation Shows the internal schematic of a single attenuator section Using the HP E1368A/69A/70A Modules Microwave Switch CommandsReset Conditions Switching Channels Example Single Channel SwitchingPower To connect C to Port 1, execute 33363K 33364K 33365K 33366K Example Multiple Channel Switching Using EXTernal Example Transfer Switch Using Two Port Switches Example Transfer Switch Using One Port Switch To route signal B to the output, execute Example 4 x 1 MultiplexerScanning Channels Selects the Trigger SourceExample Scanning Channels Output 722TRIG EXT …Example Using the Scan Complete Bit Example Multiple Channel Scanning110END Detecting Error Conditions Recalling and Saving StatesRepeat Synchronizing the Microwave Switch Synchronizing InstrumentsQuerying the Microwave Switch Common Command Format Command TypesScpi Command Format HP E1368A/69A/70A Command Reference Chapter Semicolon between the commands. For example ABORt Scpi Command ReferenceExample Stopping a Scan with ABORt For the number of scanning cycles default is ∙ Number of Scans Use only numeric values between 1Armcoun MONitorCARD Example Select Module #2 in a Switchbox for MonitoringDISPlay ∙ Selecting a Specific Module to be Monitored UseExample Querying the Monitor Mode Example Enabling the Monitor Mode∙ Selecting the Module to be Monitored Use INITiate ∙ Stopping Continuous Scans See the ABORt commandExample Enabling Continuous Scans Example Query Continuous Scanning State OUTPut Example Query Trig Out Port Enable StateExample Enabling Trig Out Port ROUTe Example Closing Microwave Switch Channels∙ Closing Channels To close Example Opening Microwave Switch Channels ∙ Opening Channels To openExample Scanning Using External Device Or any combinationChapter HP E1368A/69A/70A Command Reference STATus ∙ Setting Bit 7 of the Status Byte Register Example Query the Standard Operation Status Enable RegisterSTATOPER? SYSTem CDEScription?Example Reading the Error Queue Comments Microwave Switch Module Model NumberExample Reading the Model Number of a Card #1 Module TRIGger ∙ Executing the TRIGgerIMMediate Command a channel listExample Advancing Scan Using the TRIGger Command ∙ Hold or BUS Source Remains If selected, the TRIGgerSOURce∙ Trig Out Port Shared by Switchboxes See the OUTPut command Example Scanning Using External TriggersScanning Using Bus Triggers Example Query the Trigger SourceIeee 488.2 Common Commands HP Command Module User’s Manual, or the ANSI/IEEE StandardCommand Quick Reference Scpi Commands for Quick ReferenceHP E1368A/69A/70A Command Reference Chapter Connectors Used P1 No. Slots Characteristic Impedence 50Ω Insertion LossMaximum Input Power 1 Watt average Operating TemperatureHP E1368A/69A/70A Specifications Appendix a HP E1368A/69A/70A Registers Register DefinitionsReading the Registers Addressing the RegistersID and Device Type Registers Status/Control Register Channel Enable Register Writing to the RegistersHP E1368A/69A/70A Registers Appendix B HP E1368A/69A/70A Error Messages Page Index HP E1368A/69A/70A Modules User’s Manual IndexHP E1368A/69A/70A Modules User’s Manual Index HP-IB HP E1368A/69A/70A Modules User’s Manual Index HP E1368A/69A/70A Modules User’s Manual Index HP E1368A/69A/70A Modules User’s Manual Index