HP E1368A manual April, According to ISO/IEC Guide 22 and EN

Page 7

 

Declaration of Conformity

 

according to ISO/IEC Guide 22 and EN 45014

Manufacturer’s Name:

Hewlett-Packard Company

 

Loveland Manufacturing Center

Manufacturer’s Address:

815 14th Street S.W.

 

Loveland, Colorado 80537

declares, that the product:

Product Name: HP E1368A Microwave Switch, E1369A Microwave Switch Driver, E1370A Microwave Switch/Attenuator

Model Number: E1368A, E1369A, E1370A

Product Options:

All

conforms to the following Product Specifications:

Safety:IEC 1010-1 (1990) Incl. Amend 1 (1992)/EN61010-1 (1993)

CSA C22.2 #1010.1 (1992)

UL 1244

EMC:CISPR 11:1990/EN55011 (1991): Group1 Class A IEC 801-2:1991/EN50082-1 (1992): 4kVCD, 8kVAD IEC 801-3:1984/EN50082-1 (1992): 3 V/m

IEC 801-4:1988/EN50082-1 (1992): 1kV Power Line

.5kV Signal Lines

Supplementary Information: The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE-marking accordingly.

Tested in a typical configuration in an HP B-Size VXI mainframe.

April, 1995

Jim White, QA Manager

European contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Department HQ-TRE, Herrenberger Straße 130, D-71034 Böblingen, Germany (FAX +49-7031-14-3143).

HP E1368A, E1369A, E1370A Microwave Switch and Driver Modules User’s Manual 7

Image 7
Contents Contents Open OPEN? Scan Scanmode SCANMODE? Cpon HP E1368A/69A/70A Modules User’s Manual Contents Certification Documentation History According to ISO/IEC Guide 22 and EN AprilPage Business Reply Mail Page Microwave Switch Description Using This ChapterGetting Started with the HP E1368A/69A/70A Chapter HP E1368A Switches Power Supply CircuitInstrument Definition Programming the Microwave SwitchCard Numbers for Multiple-Module Switchboxes Initial Operation Example Reset the switchbox and close channelConfiguring the HP E1368A/69A/70A Modules Logical Address Selection Setting the Address SwitchInterrupt Priority Selection Selecting the Interrupt PriorityInstalling Switches on the Module Installing Switches on the HP E1369AChapter Configuring the HP E1368A/69A/70A Modules Microwave Switch Installation Connecting Switches External To the Module Selecting Switch Power Selecting Switch Voltage Connecting Field WiringInstalling a Switch Or Attenuator on Module Microwave Switch/Attenuator Installation Shows the internal schematic of a single attenuator section Microwave Switch Commands Using the HP E1368A/69A/70A ModulesReset Conditions Example Single Channel Switching Switching ChannelsPower To connect C to Port 1, execute 33363K 33364K 33365K 33366K Example Multiple Channel Switching Using EXTernal Example Transfer Switch Using Two Port Switches Example Transfer Switch Using One Port Switch Example 4 x 1 Multiplexer To route signal B to the output, executeSelects the Trigger Source Scanning ChannelsOutput 722TRIG EXT … Example Scanning ChannelsExample Multiple Channel Scanning Example Using the Scan Complete Bit110END Recalling and Saving States Detecting Error ConditionsRepeat Synchronizing Instruments Synchronizing the Microwave SwitchQuerying the Microwave Switch Common Command Format Command TypesScpi Command Format HP E1368A/69A/70A Command Reference Chapter Semicolon between the commands. For example ABORt Scpi Command ReferenceExample Stopping a Scan with ABORt ∙ Number of Scans Use only numeric values between 1 For the number of scanning cycles default isArmcoun ∙ Selecting a Specific Module to be Monitored Use Example Select Module #2 in a Switchbox for MonitoringDISPlay MONitorCARDExample Querying the Monitor Mode Example Enabling the Monitor Mode∙ Selecting the Module to be Monitored Use INITiate ∙ Stopping Continuous Scans See the ABORt commandExample Enabling Continuous Scans Example Query Continuous Scanning State OUTPut Example Query Trig Out Port Enable StateExample Enabling Trig Out Port ROUTe Example Closing Microwave Switch Channels∙ Closing Channels To close ∙ Opening Channels To open Example Opening Microwave Switch ChannelsOr any combination Example Scanning Using External DeviceChapter HP E1368A/69A/70A Command Reference STATus Example Query the Standard Operation Status Enable Register ∙ Setting Bit 7 of the Status Byte RegisterSTATOPER? CDEScription? SYSTemExample Reading the Error Queue Comments Microwave Switch Module Model NumberExample Reading the Model Number of a Card #1 Module ∙ Hold or BUS Source Remains If selected, the TRIGgerSOURce ∙ Executing the TRIGgerIMMediate Command a channel listExample Advancing Scan Using the TRIGger Command TRIGgerExample Scanning Using External Triggers ∙ Trig Out Port Shared by Switchboxes See the OUTPut commandExample Query the Trigger Source Scanning Using Bus TriggersHP Command Module User’s Manual, or the ANSI/IEEE Standard Ieee 488.2 Common CommandsScpi Commands for Quick Reference Command Quick ReferenceHP E1368A/69A/70A Command Reference Chapter Operating Temperature Characteristic Impedence 50Ω Insertion LossMaximum Input Power 1 Watt average Connectors Used P1 No. SlotsHP E1368A/69A/70A Specifications Appendix a Register Definitions HP E1368A/69A/70A RegistersReading the Registers Addressing the RegistersID and Device Type Registers Writing to the Registers Status/Control Register Channel Enable RegisterHP E1368A/69A/70A Registers Appendix B HP E1368A/69A/70A Error Messages Page HP E1368A/69A/70A Modules User’s Manual Index IndexHP E1368A/69A/70A Modules User’s Manual Index HP-IB HP E1368A/69A/70A Modules User’s Manual Index HP E1368A/69A/70A Modules User’s Manual Index HP E1368A/69A/70A Modules User’s Manual Index