Installing Switches on the HP E1369A
Installing Switches on the Module
Note
Because the HP E1369A Microwave Switch modules do not have Microwave Switches installed by the factory, it is necessary to install or connect switches before operating. Determine the number of switches, and whether the switches are to be installed on, or connected to, the module and proceed as instructed below.
Installation described for up to three coaxial switches (channels
HP SWITCHES. The following 5V HP 333XX series and HP 876X series switches will function in the HP E1369A Microwave Switch module.
The corresponding HP 876X and 333XX series switches shown in the table below are electrically and physically identical. The HP 8761, 8766 (33363), 8767 (33364),8768 (33365),8769 (33366) series coaxial switches will not function in the HP E1369A Microwave Switch module because the switch coils are not split (separate for each contact).
HP Part Number | Frequency | Characteristic | Ports | Internal 50Ω | Auto Coil | MTG |
|
| Impedance |
| Termination | Interrupt | Hole |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
33311B/011 or 8762B/005/100 | DC to 18 GHz | 50Ω | 3 | All ports | Yes | C |
33311C/011 or 8762C/005/100 | DC to 26.5 GHz | 50Ω | 3 | All ports | Yes | C |
33312B/011 or 8763B/005/100 | DC to 18 GHz | 50Ω | 4 | One port | Yes | D |
33312C/011 or 8763C/005/100 | DC to 26.5 GHz | 50Ω | 4 | One port | Yes | D |
33313B/011 or 8764B/005/100 | DC to 18 GHz | 50Ω | 5 | No ports | Yes | D |
33313C/011 or 8764C/005/100 | DC to 26.5 GHz | 50Ω | 5 | No ports | Yes | D |
33314A/011 or 8765A/005/100 | DC to 4 GHz | 50Ω | 3 | No ports | No | B |
33314B/011 or 8765B/005/100 | DC to 20 GHz | 50Ω | 3 | No ports | No | B |
33314C/011 or 8765C/005/100 | DC to 26.5 GHz | 50Ω | 3 | No ports | No | B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Caution The maximum current that the control circuit can accommodate is 1 amp per switch. Maximum current also depends on the output capacity of the mainframe or power supply used.
20 Configuring the HP E1368A/69A/70A Modules | Chapter 2 |