Toshiba RAV-SM801BT-E 111, Case of RAV-SM1100AT-E, Be sure to mount the propeller fan

Page 113

No.

Part name

 

Procedure

 

Remarks

 

 

 

 

 

Fan motor

1)

Perform the works in 1 of and 1 of .

Flange nut

 

 

2)

Take off flange nut fixing the fan motor with

Loosen by

 

 

 

 

the propeller fan.

 

turning clockwise.

 

 

 

 

 

 

• Loosen the flange nut by turning clock-

 

 

 

 

wise. (When tightening, turn it counter-

 

 

 

 

clockwise.)

 

 

3)Remove the propeller fan.

4)Remove connector for the fan motor from the inverter.

5)Take off fixing screws (4 pcs) with support-

ing the fan motor so that it does not fall

Propeller fan

down.

 

6)When replacing the fan motor at lower side, remove the motor lead fixed plate which is fixed to the partition plate with screw (ST1Tf4´10, 1 pc), pull the fan motor lead out of the partition plate, and then remove the fan motor.

* Cautions in assembling fan motor

 

<In case of RAV-SM1100AT-E>

Fan motor connector at upper side

• Be sure to mount the propeller fan and the

 

fan motor at upper and lower sides because

 

they are different.

 

• Tighten the flange nut with the following torque.

Upper side: 9.8N·m (100kgf·cm)

Lower side: 4.9N·m (50kgf·cm)

<In case of RAV-SM1400AT-E>

The same propeller fan and the fan motor are used at upper and lower sides.

Tighten the flange nut with the following

Cycle P.C. board

 

torque.

Fan motor connector at lower side

 

Upper side: 9.8N·m (100kgf·cm)

 

 

Lower side: 9.8N·m (100kgf·cm)

 

Be sure to mount the motor lead fixed plate

Fan motor

 

 

so that the fan motor lead is not caught in.

 

Be sure that the propeller fan does not come to contact with the fan motor lead.

Fan motor lead

Partition plate

Motor lead fixed plate

111

Image 113
Contents Split Type Contents Concealed Duct Type SpecificationsIndoor Unit RAV-SM1101BT-E RAV-SM1401BT-E RAV-SM560AT-E RAV-SM800AT-E Outdoor UnitRAV-SM1100AT-E RAV-SM1400AT-E Cooling Heating Operation Characteristic CurveHeating Capacity Variation Ratio According to TemperatureCooling AIR Ducting Work Static Pressure Characteristics of Each ModelRAV-SM1101BT-E Round duct Construction Views External Views DimensionIndoor Unit Concealed Duct Type RAV-SM561BT-E / SM801BT-E / SM1101BT-E / SM1401BT-ERAV-SM560AT-E RAV-SM800AT-E RAV-SM1100AT-E / SM1400AT-E Indoor Unit/Outdoor Unit Systematic Refrigerating Cycle DiagramIndoor unit Outdoor unitRAV-SM801BT-E RAV-SM1001BT-E Second rps Fan Indoor Outdoor StrainerIdentification Wiring DiagramColor MCC-813 Color IdentificationFor P.C. Board MCC-1359MCC-1398 MCC-1438Parts name Type Specifications Specifications of Electrical PartsRAV-SM1100AT-E Refrigerant Piping Installation Safety During Installation/ServicingRefrigerant R410A Piping Materials and Joints Used1 Thicknesses of annealed copper pipes Thickness mm Processing of Piping MaterialsOuter diameter mm R410A R22 Nominal diameterR410A clutch type Clutch type Wing nut type Flare tool for Conventional flare toolR22 clutch type Clutch type Wing nut type DiameterWrenches available on the market Nm kgfcmGeneral tools Conventional tools can be used ToolsRequired Tools Recharging of Refrigerant 1 Configuration of refrigerant chargingFlux Brazing of PipesMaterials for Brazing Never use gas other than Nitrogen gas BrazingIndoor Control Circuit Main Sub master remote controller Weekly timerIndoor Unit Control Remote controller Outline of control Command Control SpecificationsOutline of specifications Remarks Operation Heating AutoHeat Control temp C Last push priority Case of wired remote controllerCenter Operation ProhibitedTa˚C Normal control MCC-1402 Indoor Print Circuit BoardSM1401BT-E RAV-SM561BT-E / SM801BT-E / SM1101BTFunction Connector Pin Specifications Remarks Indoor P.C. Board Optional Connector SpecificationsOutdoor Control Discharge temperature release controlOutline of Main Controls Pulse Modulating Valve PMV controlMAX Allocations of fan tap revolutions Outdoor fan control Object SM560Cooling operation Heating operationHigh-pressure suppression TE control For SM800 Short intermittent operation preventive controlOver-current preventive control Current release value shift controlStart of heating operation Defrost controlMCC-813 RAV-SM560AT-E Viewed from parts of P.C board Outdoor ControlsPrint Circuit Board MCC-1398 RAV-SM800AT-E / SM1100AT-E / SM1400AT-E Summary of Troubleshooting TroubleshootingWired remote controller type Before troubleshootingError mode detected by indoor unit Check Code ListDiagnostic function Cause of operation Error mode detected by outdoor unitTimer Ready Wired remote Controller Check code Error mode detected by remote controller or network adapterSW800 LED display in bit 1, bit 2, bit 3, bit 4 OFF Error Mode Detected by LED on Outdoor P.C. BoardCDB side Ipdu sideType a SW800 LED display in bit 1, bit 2, bit 3 OFFCheck code E01 error/*99 error Troubleshooting Procedure for Each Check CodeE09 error/*99 error New Check Code/Present Check Code Central Control SideE04 error/04 error E18 error/97 error *99 error E10 error/CF errorE08, L03, L07, L08 error/ *96 error 99 error L09 error/46 errorB7 error Central controller L20 error/98 errorL30 error/B6 error F10 error 0C error P10 error/Ob errorP12 error/11 error RAV-SM1100AT-E, SM1400AT-E P22 error/1A errorSingle phase F02 error/0d error P19 error/08 errorP26 error/14 error F01 error/0F errorH03 error/17 error P29 error/16 errorF08 error/1b error F06 error/18 errorF04 error/19 error H02 error/1d error L29 error/1C errorH01 error/1F error P03 error/1E errorP04 error/21 error Error Central controller P31 error Sub indoor unit E03 error Master indoor unitF29 error / 12 error Caracteristics-3 TA sensor TC, TCJ sensor Caracteristics-2 Caracteristics-120 TE, TO, TS sensor TD sensor Caracteristics-4Case Replacement of Service Indoor P.C. BoardR2 Replacement of service P.C. board R1 Readout of the setup data from EepromContents Minimum requirements for item codeR3 Writing of the setup contents to Eeprom Indoor unit capacity Item code Memorandum for setup contents Item code table ExampleType Item code Test Run Setup on Remote Controller Setup AT Local Site and OthersSetup to Select Function Wired remote controllerDescription At shipment Item No. DN table Selection of functionOperation Cabling and Setting of Remote Controller ControlSetup method Procedure Monitor Function of Remote Controller SwitchContents Group control operation Calling of error historyRequirement System exampleNetwork Address Setup Switch SW01 Microcomputer Block DiagramLED Display Specification Network AdapterCommunication circuit Communication cable specifications Communication Cable SpecificationsCable Connection Network cable connectionHow to set from the remote controller at indoor unit side How to Set an Address NumberHow to set by the switch on the network adapter P.C. board Procedure Set the network address while the unit stopsAddress No Requirement in ServiceNetwork address No. setup table SW01 Contents Remarks Address setup procedure Address SetupAddress Setup System configuration Address Setup & Group ControlOnly turning on source power supply Automatic completion Automatic address example from unset address No miscablingSetup completes Status returns to the usual stop status Manual setting from remote controllerPush and buttons simultaneously for 4 seconds or more Push button if the unit stopsTo know the position of indoor unit body by address Detachments Part name Procedure RemarksNo. Part name Procedure Remarks † Drain pump Remove the drain pan and float switch Attachment DetachmentPart name Procedure RemarksRequirement Part name ProcedureConnection with the power terminal Take off fixed screw for the valve mounting ‡ Compressor Perform works of items 1 ‚, ƒ, „, … Fan guard Remove the upper cabinet Discharge port cabinet for the heat ex Requirement 100101 102 103 104 Product 105106 107 108 109 110 Case of RAV-SM1100AT-E 111Be sure to mount the propeller fan Case of RAV-SM1400AT-E112 113 114 Exploded Views and Parts ListPart Description Location115 904 901, 902, 903 35, 36, 37RAV-SM1001BT-E / SM1401BT-E 116RAV-SM561BT-E / SM801BT-E / SM1001BT-E / SM1401BT-E 117118 Inverter119 702 TE Sensor TS Sensor To Sensor TD Sensor 701 705 703 704120 21,22 16,17121 706122 Inverter 26,27 23,24 28,29123 TH Sensor