Bendix® AD-IP®Integral Purge and AD-IP®PuraGuard® Oil Coalescing Integral Purge Air Dryers

SD-08-2414

DESICCANT

CARTRIDGE

CABLE

MOUNTING

BRACKET

CONTROL

MOUNTING

CABLE

PORT

LOWER MOUNTING BRACKET

DELIVERY DISCHARGE

PORT

PURAGUARD® OIL

COALESCING AIR

DRYER MEDALLION

PURAGUARD OIL

COALESCING AIR

DRYER LABEL

SAFETY VALVE

SUPPLY

HEATER & THERMOSTATPORT CONNECTOR

Bendix® AD-IP®integral purge air dryer with the PuraGuard® oil coalescing cartridge and the new cable mounting bracket.

OLD STYLE

SADDLE

MOUNTING

BRACKET

EXTENDED

PURGE

PORT

Standard Bendix AD-IP integral purge air dryer shown with the old style saddle mounting bracket.

FIGURE 1 - BENDIX® AD-IP®INTEGRAL PURGE AIR DRYERS

1

Image 1
Contents SD-08-2414 To Avoid Personal Injury or Death General Safety GuidelinesDescription Dryer Troubleshooting Chart at the end of the manualGeneral OperationCharge Cycle Refer to Figure Bendix AD-IPINTEGRAL Purge AIR Dryer Purge Cycle Purge Cycle Refer to FigureBendix AD-IPAIR Dryer Sectional View Turbo CUT-OFF Feature Refer to FigureDischarge Line Unloader Refer to Figure Preventive MaintenanceOperation & Leakage Tests Rebuilding the Bendix AD-IPAIR DryerBendix AD-IP AIR Dryer Removal Bendix AD-IPAIR Dryer Heater Thermostat Connector 23 24 Reference Figure Description QtyBendix AD-IPAIR Dryer Cable Bracket Installation DisassemblyAssembly Cleaning & InspectionTotal Vehicle Reservoir Volume Requirement Bendix AD-IPAIR Dryer InstallationRetrofitting the AD-IP AIR Dryer Vehicle Application RequirementsLocating Bendix AD-IPAIR Dryer on the Vehicle Vehicle PreparationMounting the AD-IP AIR Dryer Refer to FigureWiring the Heater & Thermostat Refer to Figure Connecting the AIR LinesCompressor Discharge Line Purge Exhaust LineTesting the Bendix AD-IPAIR Dryer Perform tests 1 to 6 in the order presented Symptoms Cause RemedyBendix AD-IPAIR Dryer Troubleshooting Chart Bendix AD-IPAIR Dryer Troubleshooting Chart Minimum of 30 seconds. This minimum purge Air compressor must remain unloaded for aBulletins TCH-008-021 and TCH-008-022. Shorter Is not covered under the warrantyRefer to Appendix A, Table a columns 3 & 4 for ColumnLeakage. Refer to Technical Bulletin TCH-008-040 Preventative Maintenance SectionRefer to Remedy C, Symptom #1 See Causes and Remedies for Symptoms 1, 2High Air Use Low Air UseHolset Integral Purge AIR DryerType E & QE CompressorComplaint Can Not Build System Pressure Complaints Common to the Charging & AIR Supply SystemComplaint Air System Builds Too Slow Complaint Can Not Build System Pressure Above X psiComplaint System Pressure Goes to 150+ psi Log-on and Learn from the Best Tests Common to More than ONE Complaint