BENDIX SD-08-2414 manual Leakage. Refer to Technical Bulletin TCH-008-040

Page 24

BENDIX® AD-IP®AIR DRYER TROUBLESHOOTING CHART

SYMPTOMS

CAUSE

REMEDY

5. Constant exhaust

A. Air dryer purge valve is

A. With the compressor loaded, apply a soap solution

of air at air dryer

leaking excessively.

on the purge valve exhaust, to test for excessive

purge valve exhaust.

 

leakage. Refer to Technical Bulletin TCH-008-040.

(Charge mode.)

 

Repair the purge valve as necessary.

 

B. Compressor fails to unload

B. Confirm the failure to unload by increasing &

 

(stop compressing air) and

decreasing engine RPM and noting change in the

 

the air dryer purge exhaust

rate of leakage and intensity of accompanying

 

makes “sputtering” or

leakage sound. Repair/replace compressor

 

“popping” sound.

unloaders.

 

C. Purge control line connected

C. Purge control line must be connected to unloader

 

to reservoir or exhaust port

port of governor.

 

of governor.

 

 

D. Purge valve frozen open -

D. Test the heater and thermostat as described in

 

malfunctioning heater and

Preventative Maintenance Section.

 

thermostat, wiring, blown

 

 

fuse.

 

 

E. Excessive system leakage.

E. See Symptom #1.

 

 

 

 

F. Purge valve stays open -

F. Repair the purge valve and housing.

 

supply air leaks to control

 

 

side.

 

6. Can not build system

A. Inlet and outlet air

A. Connect compressor discharge to the air dryer

air pressure.

connections reversed.

supply port. Reconnect the lines properly.

 

B. Check valve between the air

B. Test the check valve for proper operation. Repair

 

dryer and first reservoir.

or replace as necessary.

 

C. Kinked or blocked (plugged)

C. Check to determine if air passes through the

 

discharge line.

discharge line. Check for kinks, bends, excessive

 

 

carbon deposits, or ice blockage.

 

D. Excessive bends in

D. Discharge line should be constantly sloping from

 

discharge line (water collects

the compressor to the air dryer with as few bends

 

and freezes)

as possible.

 

E. Refer to Symptom 4, Causes

E. Refer to Symptom #4, Remedies E & F.

 

E & F.

 

 

 

 

7. Air dryer does not

A. Missing, broken, kinked,

A. Inspect control line from the governor UNL

purge or exhaust air.

frozen, plugged or

(unloader) port to control port of air dryer. Test to

 

disconnected purge control

determine if air flows through purge control line

 

line.

when compressor unloaded. Check for undrilled

 

 

fittings. (See Symptom #4, Remedy C.)

 

B. Faulty air dryer purge valve.

B. After determining the air reaches the purge valve

 

 

(Remedy A above), repair the purge valve.

 

C. See Causes, B, E, G for

C. Refer to Remedies B, E, G for Symptom #4.

 

Symptom #4.

 

24

Image 24
Contents SD-08-2414 General Safety Guidelines To Avoid Personal Injury or DeathDryer Troubleshooting Chart at the end of the manual DescriptionOperation GeneralCharge Cycle Refer to Figure Purge Cycle Refer to Figure Bendix AD-IPINTEGRAL Purge AIR Dryer Purge CycleTurbo CUT-OFF Feature Refer to Figure Bendix AD-IPAIR Dryer Sectional ViewPreventive Maintenance Discharge Line Unloader Refer to FigureRebuilding the Bendix AD-IPAIR Dryer Operation & Leakage TestsBendix AD-IP AIR Dryer Removal Bendix AD-IPAIR Dryer Heater Thermostat Connector 23 24 Description Qty Reference FigureDisassembly Bendix AD-IPAIR Dryer Cable Bracket InstallationCleaning & Inspection AssemblyBendix AD-IPAIR Dryer Installation Total Vehicle Reservoir Volume RequirementRetrofitting the AD-IP AIR Dryer Vehicle Application RequirementsVehicle Preparation Locating Bendix AD-IPAIR Dryer on the VehicleMounting the AD-IP AIR Dryer Refer to FigureConnecting the AIR Lines Wiring the Heater & Thermostat Refer to FigureCompressor Discharge Line Purge Exhaust LineTesting the Bendix AD-IPAIR Dryer Symptoms Cause Remedy Perform tests 1 to 6 in the order presentedBendix AD-IPAIR Dryer Troubleshooting Chart Bendix AD-IPAIR Dryer Troubleshooting Chart Air compressor must remain unloaded for a Minimum of 30 seconds. This minimum purgeIs not covered under the warranty Bulletins TCH-008-021 and TCH-008-022. ShorterColumn Refer to Appendix A, Table a columns 3 & 4 forPreventative Maintenance Section Leakage. Refer to Technical Bulletin TCH-008-040See Causes and Remedies for Symptoms 1, 2 Refer to Remedy C, Symptom #1Low Air Use High Air UseIntegral Purge AIR Dryer HolsetType E & QE CompressorComplaints Common to the Charging & AIR Supply System Complaint Can Not Build System PressureComplaint Air System Builds Too Slow Complaint Can Not Build System Pressure Above X psiComplaint System Pressure Goes to 150+ psi Tests Common to More than ONE Complaint Log-on and Learn from the Best