BENDIX SD-08-2414 manual Description Qty, Reference Figure

Page 11

 

Item

 

Description

 

Qty.

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference Figure 8

 

 

 

1

 

 

5/16” Cap Screw

1

 

 

 

 

 

 

 

 

 

 

2

 

 

O-ring

1

 

3

 

 

5/16” Sleeve Nut

1

 

4

 

 

Mounting Strap

1

 

5

 

 

Saddle Bracket

1

 

6

 

 

End Cover

1

 

7

 

 

3/8” Cap Screw

2

 

8

 

 

3/8” Lock Washer

2

 

9

 

 

Lower Mounting Bracket

1

 

 

 

 

 

 

 

 

 

 

10

 

 

Cartridge Bolt

1

 

11

 

 

Desiccant Cartridge

1

 

 

 

 

 

 

 

 

 

 

12

 

 

O-ring

1

 

13

 

 

O-ring

1

 

14

 

 

Retaining Ring

1

 

15

 

 

Purge Valve Cartridge Assembly

1

 

 

 

 

 

 

 

 

 

 

*16

 

 

Installation Ring

1

 

17

 

 

O-ring

1

 

 

 

 

 

 

 

 

 

 

18

 

 

O-ring

1

 

19

 

 

O-ring

1

 

20

 

 

Retaining Ring

1

 

21

 

 

Heater & Thermostat Assembly

1

 

22

 

 

Safety Valve Assembly

1

 

 

 

 

 

 

 

 

 

 

23

 

 

Delivery Check Valve Plug

1

 

24

 

 

Spring

1

 

25

 

 

Check Valve Body (white)

1

 

 

 

 

 

Reference Figure 9

 

 

 

26

 

 

Perforated Plate

1

 

27

 

 

Check Ring Spring

1

 

28

 

 

Check Valve

1

 

29

 

 

O-ring

1

 

 

 

 

 

 

 

 

 

 

30

 

 

Retaining Ring

1

 

 

 

 

 

Reference Figure 10

 

 

 

31

 

 

Upper Bracket

1

 

32

 

 

Cable Assembly

1

 

 

 

 

 

 

 

 

 

 

33

 

 

Isolator

2

 

34

 

 

Locknut

1

 

35

 

 

Washer

1

 

 

 

 

 

 

 

 

 

 

DELIVERY PORT

PIPE PLUG(TO SUPPLY

RESERVOIR)

CONTROL PORT

(FROM GOVERNOR

AIR DRYER UNLOADER PORT) END COVER

DELIVERY PORT

 

 

(TO SUPPLY

29

SUPPLY PORT

RESERVOIR)

(FROM

 

 

COMPRESSOR)

28

27

 

26

30

 

 

 

Old Style Bendix® AD-IP®End Cover -

Vertical Delivery Check Valve

FIGURE 9 - BENDIX® AD-IP®AIR DRYER INTERNAL COMPONENTS –

VERTICAL DELIVERY CHECK VALVE

11

Image 11
Contents SD-08-2414 To Avoid Personal Injury or Death General Safety GuidelinesDescription Dryer Troubleshooting Chart at the end of the manualCharge Cycle Refer to Figure OperationGeneral Bendix AD-IPINTEGRAL Purge AIR Dryer Purge Cycle Purge Cycle Refer to FigureBendix AD-IPAIR Dryer Sectional View Turbo CUT-OFF Feature Refer to FigureDischarge Line Unloader Refer to Figure Preventive MaintenanceBendix AD-IP AIR Dryer Removal Rebuilding the Bendix AD-IPAIR DryerOperation & Leakage Tests Bendix AD-IPAIR Dryer Heater Thermostat Connector 23 24 Reference Figure Description QtyBendix AD-IPAIR Dryer Cable Bracket Installation DisassemblyAssembly Cleaning & InspectionVehicle Application Requirements Bendix AD-IPAIR Dryer InstallationTotal Vehicle Reservoir Volume Requirement Retrofitting the AD-IP AIR DryerRefer to Figure Vehicle PreparationLocating Bendix AD-IPAIR Dryer on the Vehicle Mounting the AD-IP AIR DryerPurge Exhaust Line Connecting the AIR LinesWiring the Heater & Thermostat Refer to Figure Compressor Discharge LineTesting the Bendix AD-IPAIR Dryer Perform tests 1 to 6 in the order presented Symptoms Cause RemedyBendix AD-IPAIR Dryer Troubleshooting Chart Bendix AD-IPAIR Dryer Troubleshooting Chart Minimum of 30 seconds. This minimum purge Air compressor must remain unloaded for aBulletins TCH-008-021 and TCH-008-022. Shorter Is not covered under the warrantyRefer to Appendix A, Table a columns 3 & 4 for ColumnLeakage. Refer to Technical Bulletin TCH-008-040 Preventative Maintenance SectionRefer to Remedy C, Symptom #1 See Causes and Remedies for Symptoms 1, 2High Air Use Low Air UseCompressor Integral Purge AIR DryerHolset Type E & QEComplaint Can Not Build System Pressure Above X psi Complaints Common to the Charging & AIR Supply SystemComplaint Can Not Build System Pressure Complaint Air System Builds Too SlowComplaint System Pressure Goes to 150+ psi Log-on and Learn from the Best Tests Common to More than ONE Complaint