BENDIX SD-08-2414 manual 23 24

Page 10

11

1

4

3

5

6

19

22

21

 

 

20

23 24 25

12

13

10

 

 

 

16

2

 

 

 

 

 

 

 

 

 

 

17 18

15

STANDARD

STYLE PURGE

VALVE

 

9

 

SLIDE INSTALLATION

 

RING INTO PURGE

 

BORE

8

 

7

 

*16

APPLY LUBRICANT

18

TO INSIDE

SURFACE

14

15

INSTALLATION RING -

 

(NOTE THE ORIENTATION

 

DISCHARGE LINE

 

OF THE BEVEL OF THE RING

 

UNLOADED (DLU)

BEFORE INSTALLATION.)

 

STYLE PURGE VALVE

 

 

 

14

*Most OE installed Bendix® AD-IP®air dryers manufactured after January 1, 2014 will not be equipped with a purge valve installation ring (16). The function of the installation ring has been incorporated into the air dryer lower housing. Be sure to replace the installation ring if it was removed during servicing procedures.

FIGURE 8 - BENDIX® AD-IP®AIR DRYER INTERNAL COMPONENTS – HORIZONTAL DELIVERY CHECK VALVE

10

Image 10
Contents SD-08-2414 General Safety Guidelines To Avoid Personal Injury or DeathDryer Troubleshooting Chart at the end of the manual DescriptionGeneral OperationCharge Cycle Refer to Figure Purge Cycle Refer to Figure Bendix AD-IPINTEGRAL Purge AIR Dryer Purge CycleTurbo CUT-OFF Feature Refer to Figure Bendix AD-IPAIR Dryer Sectional View Preventive Maintenance Discharge Line Unloader Refer to FigureOperation & Leakage Tests Rebuilding the Bendix AD-IPAIR DryerBendix AD-IP AIR Dryer Removal Bendix AD-IPAIR Dryer Heater Thermostat Connector 23 24 Description Qty Reference FigureDisassembly Bendix AD-IPAIR Dryer Cable Bracket InstallationCleaning & Inspection AssemblyRetrofitting the AD-IP AIR Dryer Bendix AD-IPAIR Dryer InstallationTotal Vehicle Reservoir Volume Requirement Vehicle Application RequirementsMounting the AD-IP AIR Dryer Vehicle PreparationLocating Bendix AD-IPAIR Dryer on the Vehicle Refer to FigureCompressor Discharge Line Connecting the AIR LinesWiring the Heater & Thermostat Refer to Figure Purge Exhaust LineTesting the Bendix AD-IPAIR Dryer Symptoms Cause Remedy Perform tests 1 to 6 in the order presentedBendix AD-IPAIR Dryer Troubleshooting Chart Bendix AD-IPAIR Dryer Troubleshooting Chart Air compressor must remain unloaded for a Minimum of 30 seconds. This minimum purgeIs not covered under the warranty Bulletins TCH-008-021 and TCH-008-022. ShorterColumn Refer to Appendix A, Table a columns 3 & 4 forPreventative Maintenance Section Leakage. Refer to Technical Bulletin TCH-008-040See Causes and Remedies for Symptoms 1, 2 Refer to Remedy C, Symptom #1Low Air Use High Air UseType E & QE Integral Purge AIR DryerHolset CompressorComplaint Air System Builds Too Slow Complaints Common to the Charging & AIR Supply SystemComplaint Can Not Build System Pressure Complaint Can Not Build System Pressure Above X psiComplaint System Pressure Goes to 150+ psi Tests Common to More than ONE Complaint Log-on and Learn from the Best