Raypak 1334001 operating instructions Vent Damper, Installation

Page 19

 

HORIZONTAL INSTALLATION

 

 

 

FLOW >

 

NO

 

 

 

 

 

 

 

 

YES

YES

TO HEATER

D808

TO CHIMNEY

 

 

 

 

 

NO

 

VERTICAL

 

INSTALL VENT

 

INSTALLATION

 

 

 

DAMPER WITH

 

 

 

TO CHIMNEY

 

 

 

ACTUATOR TO

 

 

 

 

 

 

 

 

SIDES OF VENT

 

 

 

 

ONLY. DO NOT

 

 

 

D808

MOUNT ABOVE OR

 

 

 

BELOW VENT.

 

 

 

 

ACTUATOR MAY BE

 

 

 

 

INSTALLED IN ANY

 

 

 

TO HEATER

POSITION ON

 

 

 

 

VERTICAL PIPE.

 

Fig. 16: Installing Vent Damper

Vent Damper

For safe, efficient operation, the vent damper and all flue product carrying areas of the appliance must be checked annually, with particular attention given to deterioration from corrosion or other sources. Check vent damper operation as follows:

1.When the heater is off, check that the vent damper position indicator points to the closed position, Fig. 18.

Damper

Damper

Position

Position

Indicator

Indicator

 

 

 

D808

 

 

 

 

N.O.

N.C.

 

 

 

 

 

End

 

1K2

 

 

 

 

Switch

 

 

 

 

 

 

C.

 

 

1K1

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

R

 

 

1K3

 

 

 

 

 

 

 

 

1R

 

 

 

 

1

 

2

3

4

5

Black

Orange

Red

 

 

Yellow

Blue

 

 

 

 

 

 

Limit

 

 

 

Thermostat or

 

 

 

 

 

Controller

 

 

 

 

Dual Valve

 

 

 

 

Combination Gas

 

 

 

 

Control or

 

 

 

Transformer

 

Ignition System

 

 

 

Optional Limit

Location

L1

(Hot)

L2

1

DAMPER OPEN

DAMPER CLOSED

Fig. 18: Vent Damper position Indicator Showing Open

&Closed Positions

2.Turn the thermostat or controller up to call for heat and check that the vent damper indicator points to the open position, Fig. 18.

3.Turn the thermostat or controller down again and check that the vent damper position indicator returns to the closed position.

THE VENT DAMPER MUST BE INSPECTED AT

1Power supply provide disconnect means an overload protection as required.

Fig. 17: Vent Damper General Wiring Diagram

INSTALL THE VENT DAMPER TO SERVICE ONLY THE SINGLE APPLIANCE FOR WHICH IT IS INTENDED. IF IMPROPERLY INSTALLED, A HAZ- ARDOUS CONDITION, SUCH AS AN EXPLOSION OR CARBON MONOXIDE POISONING, COULD RESULT.

LEAST ONCE A YEAR BY A TRAINED, EXPERI- ENCED SERVICE TECHNICIAN. THE NAME OF THE PERSON WHO ORIGINALLY INSTALLED YOUR VENT DAMPER IS SHOWN ON THE INSTALLATION LABEL. DAMPER MUST BE IN THE OPEN POSI- TION WHEN HEATER MAIN BURNERS ARE OPERATING.

19

Image 19
Contents Raytherm Hot Water Supply Heaters Page Contents If Propane is Present or Suspected Feel water before bathing or show- ering General SafetyTemperature limiting valves are available, see manual Temperature Time to Produce Serious BurnReceiving Equipment Time/Temperature Relationships in ScaldsModel Identification Installation Clearances Installation Clearances All Dimensions are in InchesModel Part Number Model Specifications and DimensionsModels 0182-0400 MBH ModelsMBH GPH High Wind Conditions Outdoor Units Only Outdoor Water HeatersModels 0181-0401 Outdoor InstallationsVent Terminal Outdoor Stackless Top Installation VentingIndoor Installations Indoor Top Installation Models 0181-0401 Vent Terminal/Indoor Stack Installation Vent Piping Vent PipingMounting Vent Damper InstallationModels 0133 Through 0180 Where Required LocationVent Damper InstallationGeneral PlumbingGas Supply Connections Venting of Diaphragm Gas Components Gas Pressure RegulatorMaximum and Minimum Flow Rates Flow RatesSoft Medium Hard Piping-Domestic Hot Water Supply HeatersPiping Diagram-Type WH Unitemp 80 System Electronic Ignition Pump Time DelayControls-General Relief ValveLimit Controls Flow SwitchHigh Limit Low Water Cut-Off Optional 100% Pilot SafetyHigh and Low Gas Pressure Switches Optional Electrical ConnectionsLocation of Controls 0824 Initial Start-Up Pump and Motor START-UP ProceduresBefore Start-Up GeneralFor Your Safety Read Before Operating After Start-Up Inspection ProceduresBurners ControlsShould be checked monthly. Takes approximately 15 minutes Inspection ProceduresStart-Up Procedures S8610b Ignition Module OperationElectrical Burner AdjustmentHigh Gas Pressure Switch Visual InspectionPilot Removal Main burner And Orifice RemovalCombustion Fan Removal Intermittent Pilot System Honeywell S8600 Electrical-Electronic Ignition IIDMechanical Mechanical Problem Possible Cause Corrective ActionWiring Diagram-W2/WH2 Wiring DiagramsWiring Diagram-WH1 0181/0261 Wiring Diagram-WH1 0331/0401 Wiring Diagram-WH1 Wiring Diagram-WH1 Wiring Diagram-WH1 Wiring Diagram-WH1 Troubleshooting-Pumps Service Maintenance ProceduresTube Cleaning Combination Flame SENSOR/ Igniter and Pilot Burner Heat Exchanger Removal Pilot Removal and CleaningHeat Exchanger Re-Assembly High Limit or Tankstat RemovalCleaning Flue Gas Passageways Replacement PartsControl Well Replacement Tube ReplacementScope Page