Pentair 4/160, 4/100 important safety instructions Top view

Page 14

8

Priming the pump for the first time or after service (Continued)

Priming the Pump

Release all pressure from filter, pump, and piping system; see the filter owner’s manual.

In a flooded suction system (water source higher than pump), the IntelliFlo 4 pump will prime itself when suction and discharge valves are opened.

If the IntelliFlo 4 pump is not in a flooded suction system, unscrew and remove lid cover; fill the and pump with water.

Do not lubricate the trap cover o-ring. The original equipment o-ring contains a permanent internal lubricant.

NOTICE: If you replace the o-ring with a non-internally lubricated o-ring, you may need to apply a silicone based lubricant.

Clean and inspect o-ring; reinstall on trap cover.

Replace trap cover on trap; turn clockwise to tighten cover.

NOTICE: Tighten the pump lid by hand only (no wrenches)!

Pump should prime now. Priming time will depend on vertical length of suction lift and horizontal length of suction piping. If pump does not prime, make sure that all valves are open, suction pipe end is under water, pump suction is below water level, and that there are no leaks in suction pipe.

To prime the IntelliFlo 4 pump:

1.Turn the pump clamp and lid in a counterclockwise direction until it stops and remove them.

2.Fill the pump strainer pot with water.

3.Reinstall the pump clamp and lid onto the strainer pot. The pump is now ready to prime.

4.Make sure all electrical connections are clean and tight.

5.Open the air release valve on the filter, and stand clear of the filter.

6.Switch the IntelliFlo pump on at the circuit breaker. Ensure that the

green power light is on.

Top view

 

7.Press the Speed 1 button to select the pump speed of 750 RPM.

8.Press the Start button to start the pump. Use the Up/Down button to increase the speed as necessary to prime the pump.

9.When water comes out of the air release valve, close the valve. The system should now be circulating water back to the pool without air bubbles showing in either the hair and lint pot or at the pool return fittings.

10.Use the Up/Down button to adjust the operating speed as desired.

IntelliFlo 4 Installation and User’s Guide

Image 14
Contents IntelliFlo 4/160 and 4/100 Customer Support Moorpark, California 8 A.M. to 5 P.MContents Important Safety Precautions Important NoticeImportant Safety Precautions General Installation Information General WarningsExternal Control IntelliFlo 4 Variable Speed PumpIntelliFlo 4 models IntelliFlo 4 Motor Assembly FeaturesIntelliFlo 4 Drive Assembly and Control Panel IntelliFlo 4 Operator Control Panel Controls and LEDsSetting the pump preset speed Adjusting the pump speedStarting the pump Resetting the pump to factory defaultsAssigning a pump address for remote control Stopping the pumpPriming the pump for the first time or after service Disconnect the communication cable from the pumpTop view External Control with IntelliComm Communication Center External ControlConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Connecting IntelliFlo to IntelliTouch Pin Configuration for IntelliFlo 4 to IntelliTouchPump Strainer Basket Service Pump Strainer BasketMotor Service Priming the pump after service WinterizingBlank Location IntelliFlo 4 Kit ContentsInstalling the IntelliFlo PipingWiring the IntelliFlo Pump Disassembly Shaft Seal Replacement Pump DisassemblyPump Reassembly/Seal Replacement Drive Assembly Removal and Installation Illustrated Parts List Replacement PartsIntelliflo Flow and Power vs Flow Pump Curve IntelliFlo 4 Electrical SpecificationsIntelliFlo Pump Dimensions Blank Troubleshooting Alarm and warning LED sequenceGeneral IntelliFlo 4 Troubleshooting Problems Problem Possible Cause Corrective ActionProblems and Corrective Action ActiveIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B