Pentair 4/100, 4/160 Setting the pump preset speed, Adjusting the pump speed

Page 11

5

Section 2

Operating IntelliFlo 4

This section describes how to use the IntelliFlo 4 pump control panel.

Setting the pump preset speed

IntelliFlo 4 operates using one of the preset speeds. Use the speed buttons to select the preset speeds.

To set the pump speed

1.Ensure that the pump is powered on and the green power LED is on.

2.Press the desired speed button (1- 4) for less than three seconds to select the preset pump speed. When the selected speed button is pressed, the LED is on. The pump preset buttons and speeds are:

Speed 1 button - 750 RPM

Speed 2 button - 1500 RPM

Speed 3 button - 2350 RPM

Speed 4 button - 3110 RPM

3. Press the Start button to start the pump using the selected speed if necessary.

Adjusting the pump speed

IntelliFlo can be adjusted to run at any speed between 400 RPM and 3450 RPM.

To adjust the pump speed

1. Ensure that the pump is powered on and the green power LED is on.

2. Press the Start button to start the pump if the pump is not running.

3.Press the UP/Down button to increase or decrease the pump speed.

10 RPM increments: Press and quickly release the Up/Down button to increase or decrease the speed in 10 RPM increments.

20 RPM increments: Press and hold the Up/Down button to continuously increase or decrease the pump speed.

4.Saving an adjusted speed: To save the newly adjusted pump speed, press and hold the desired speed buttons to assign the current speed. Four new pump speeds can be assigned to Speed buttons (1-4).

Up/Down button

5. Press the Speed button that is assigned to the adjusted speed.

IntelliFlo 4 Installation and User’s Guide

Image 11
Contents IntelliFlo 4/160 and 4/100 Moorpark, California 8 A.M. to 5 P.M Customer SupportContents Important Notice Important Safety PrecautionsImportant Safety Precautions General Warnings General Installation InformationExternal Control IntelliFlo 4 Variable Speed PumpIntelliFlo 4 models Features IntelliFlo 4 Motor AssemblyIntelliFlo 4 Drive Assembly and Control Panel Controls and LEDs IntelliFlo 4 Operator Control PanelAdjusting the pump speed Setting the pump preset speedStopping the pump Resetting the pump to factory defaultsAssigning a pump address for remote control Starting the pumpDisconnect the communication cable from the pump Priming the pump for the first time or after serviceTop view External Control External Control with IntelliComm Communication CenterConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Pin Configuration for IntelliFlo 4 to IntelliTouch Connecting IntelliFlo to IntelliTouchPump Strainer Basket Pump Strainer Basket ServiceMotor Service Winterizing Priming the pump after serviceBlank Piping IntelliFlo 4 Kit ContentsInstalling the IntelliFlo LocationWiring the IntelliFlo Pump Disassembly Shaft Seal Replacement Pump DisassemblyPump Reassembly/Seal Replacement Drive Assembly Removal and Installation Replacement Parts Illustrated Parts ListIntelliflo Flow and Power vs Flow Pump Curve IntelliFlo 4 Electrical SpecificationsIntelliFlo Pump Dimensions Blank Alarm and warning LED sequence TroubleshootingProblem Possible Cause Corrective Action General IntelliFlo 4 Troubleshooting ProblemsActive Problems and Corrective ActionIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B