Pentair 4/100, 4/160 Priming the pump for the first time or after service

Page 13

7

Priming the pump for the first time or after service

Before the IntelliFlo 4 pump is started for the first time it must be primed. To prime a pump means filling the pump and suction pipe with water. This process evacuates the air from all the suction lines and the pump. It may take several minutes to prime depending on the depth of water, pipe size and length. It is easier to prime a pump if you allow all the air to escape from the pump and pipes. The water cannot enter unless the air can escape. Pumps do not hold prime, the pool piping system has that task.

CAUTION - To avoid permanent damage to the IntelliFlo 4 pump, before starting the pump, fill the IntelliFlo housing strainer with water so that the pump will prime correctly. If there is no water in the stainer the pump will not prime.

NEVER run the pump dry! Running the pump dry may damage the seals, causing leakage and flooding!

Do not add chemicals to the system directly in front of pump suction. Adding undiluted chemicals may damage the pump and will void the warranty.

Open gate valves before starting system.

Pump will prime itself when used in flooded suction system.

Be sure to release all air from filter and piping system.

The IntelliFlo 4 pump is a variable speed pump. Typically the lower speeds are used for filtration and heating. The higher speeds can be used for spa jets, water features, and priming.

CAUTION - Before starting this procedure, first read the following

Before removing the pump lid:

1. Press the Stop button if the pump is running before proceeding.

1.Disconnect the communication cable from the pump.

2.Close the gate valves in suction and discharge pipes.

3.Release all pressure from pump and piping system.

4.Never tighten or loosen the clamp while the pump is operating.

WARNING! If the pump is being pressure tested, release all pressure before removing the trap cover.

Do not block the pump suction while the pump is running. If a body part blocks the pump suction it may cause severe or fatal injury. Small children using the pool must ALWAYS have close adult supervision.

WARNING! FIRE and BURN HAZARD - The pump motor may run at a high temperatures. To reduce the risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, shut off the motor and allow it to cool for 20 minutes before trying to work on it. The IntelliFlo 4 provides an automatic internal cutoff switch to protect the motor from heat damage during operation.

IntelliFlo 4 Installation and User’s Guide

Image 13
Contents IntelliFlo 4/160 and 4/100 Moorpark, California 8 A.M. to 5 P.M Customer SupportContents Important Notice Important Safety PrecautionsImportant Safety Precautions General Warnings General Installation InformationIntelliFlo 4 models IntelliFlo 4 Variable Speed PumpExternal Control Features IntelliFlo 4 Motor AssemblyIntelliFlo 4 Drive Assembly and Control Panel Controls and LEDs IntelliFlo 4 Operator Control PanelAdjusting the pump speed Setting the pump preset speedAssigning a pump address for remote control Resetting the pump to factory defaultsStarting the pump Stopping the pumpDisconnect the communication cable from the pump Priming the pump for the first time or after serviceTop view External Control External Control with IntelliComm Communication CenterConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Pin Configuration for IntelliFlo 4 to IntelliTouch Connecting IntelliFlo to IntelliTouchPump Strainer Basket Pump Strainer Basket ServiceMotor Service Winterizing Priming the pump after serviceBlank Installing the IntelliFlo IntelliFlo 4 Kit ContentsLocation PipingWiring the IntelliFlo Pump Disassembly Pump Reassembly/Seal Replacement Pump DisassemblyShaft Seal Replacement Drive Assembly Removal and Installation Replacement Parts Illustrated Parts ListIntelliFlo Pump Dimensions IntelliFlo 4 Electrical SpecificationsIntelliflo Flow and Power vs Flow Pump Curve Blank Alarm and warning LED sequence TroubleshootingProblem Possible Cause Corrective Action General IntelliFlo 4 Troubleshooting ProblemsActive Problems and Corrective ActionIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B