Pentair 4/160, 4/100 important safety instructions IntelliFlo 4 Motor Assembly, Features

Page 8

2

Features

Adjusts to various pool sizes

Prevents thermal overload

Detects and prevents damage from under and over voltage conditions

Protects against freezing

Communicates with a Pentair IntelliTouch, EasyTouch and IntelliComm system via a two-wire connection

Easy to use operator control panel

Operator control panel buttons for speed control

Built-in strainer pot and volute

Ultra energy-efficient TEFC Square Flange Motor

Compatibility with most cleaning systems, filters, and jet action spas

Driver assembly features permanent magnet synchronous motor

Heavy-duty, durable construction designed for long life

UL approval

IntelliFlo 4 Motor Assembly

The IntelliFlo three-phase six-pole motor operates at 3400 RPM (at 92% efficiency) and 1000 RPM (at 90%). The motor assembly is continually cooled by an external fan. Dual seals on the motor shaft and at the fan assembly seal the entire motor from any moisture from entering the motor assembly. For added protection, a slinger located in front of the main shaft seal assists in slinging water away from the shaft opening in the flange.

Motor fan cover

Motor assembly

Drive assembly and electronics enclosure

Control panel cover

Communication port for connection to IntelliTouch, EasyTouch or IntelliComm system via two-wire RS-485 cable

IntelliFlo 4 Motor Assembly

IntelliFlo 4 Installation and User’s Guide

Image 8
Contents IntelliFlo 4/160 and 4/100 Customer Support Moorpark, California 8 A.M. to 5 P.MContents Important Safety Precautions Important NoticeImportant Safety Precautions General Installation Information General WarningsExternal Control IntelliFlo 4 Variable Speed PumpIntelliFlo 4 models IntelliFlo 4 Motor Assembly FeaturesIntelliFlo 4 Drive Assembly and Control Panel IntelliFlo 4 Operator Control Panel Controls and LEDsSetting the pump preset speed Adjusting the pump speedResetting the pump to factory defaults Assigning a pump address for remote controlStarting the pump Stopping the pumpPriming the pump for the first time or after service Disconnect the communication cable from the pumpTop view External Control with IntelliComm Communication Center External ControlConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Connecting IntelliFlo to IntelliTouch Pin Configuration for IntelliFlo 4 to IntelliTouchPump Strainer Basket Service Pump Strainer BasketMotor Service Priming the pump after service WinterizingBlank IntelliFlo 4 Kit Contents Installing the IntelliFloLocation PipingWiring the IntelliFlo Pump Disassembly Shaft Seal Replacement Pump DisassemblyPump Reassembly/Seal Replacement Drive Assembly Removal and Installation Illustrated Parts List Replacement PartsIntelliflo Flow and Power vs Flow Pump Curve IntelliFlo 4 Electrical SpecificationsIntelliFlo Pump Dimensions Blank Troubleshooting Alarm and warning LED sequenceGeneral IntelliFlo 4 Troubleshooting Problems Problem Possible Cause Corrective ActionProblems and Corrective Action ActiveIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B