Pentair 4/100, 4/160 Connecting IntelliFlo 4 to an IntelliTouch System

Page 19

13

Connecting IntelliFlo 4 to an IntelliTouch System

The IntelliFlo 4 can be controlled by an IntelliTouch system via the RS-485 communication cable

(P/N 350122). In this configuration, IntelliTouch 4 starts, stops and controls the speed of the IntelliFlo 4 pump. When the IntelliTouch does this, it rewrites the IntelliFlo 4 memory, which can take several seconds. This causes a delay after a command is given on the IntelliTouch control panel until the Intelliflo 4 physically responds.

The IntelliFlo 4 control panel is disabled when communicating with the IntelliTouch system. Note that IntelliTouch will not start communicating with the IntelliFlo 4 until the appropriate pump address is assigned to a circuit. The IntelliFlo 4 default pump address is one. See page 6 for details about how to check the address and change if necessary. For more information, refer to the IntelliTouch User's Guide (P/N 520102).

To connect the IntelliFlo 4 communication cable to IntelliTouch load center:

1. CAUTION - Switch the main power off to the IntelliTouch load center.

2.Unlatch the IntelliTouch load center front door spring latches, and open the front door.

3.Remove the cover-panel screws securing the high voltage cover-panel, and remove it from the enclosure.

4.Loosen the two control panel access screws and fold down the outdoor control panel.

5.Insert the two-wire cable into plastic grommet on the bottom of the enclosure and route the wire up through the low voltage raceway to the Personality board.

Personality Board

Low voltage raceway

Plastic grommet

Access

screw

Cover-panel

screw

(Cover-panel not

shown)

IntelliTouch Load Center

IntelliFlo 4 Installation and User’s Guide

Image 19
Contents IntelliFlo 4/160 and 4/100 Moorpark, California 8 A.M. to 5 P.M Customer SupportContents Important Notice Important Safety PrecautionsImportant Safety Precautions General Warnings General Installation InformationIntelliFlo 4 models IntelliFlo 4 Variable Speed PumpExternal Control Features IntelliFlo 4 Motor AssemblyIntelliFlo 4 Drive Assembly and Control Panel Controls and LEDs IntelliFlo 4 Operator Control PanelAdjusting the pump speed Setting the pump preset speedStopping the pump Resetting the pump to factory defaultsAssigning a pump address for remote control Starting the pumpDisconnect the communication cable from the pump Priming the pump for the first time or after serviceTop view External Control External Control with IntelliComm Communication CenterConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Pin Configuration for IntelliFlo 4 to IntelliTouch Connecting IntelliFlo to IntelliTouchPump Strainer Basket Pump Strainer Basket ServiceMotor Service Winterizing Priming the pump after serviceBlank Piping IntelliFlo 4 Kit ContentsInstalling the IntelliFlo LocationWiring the IntelliFlo Pump Disassembly Pump Reassembly/Seal Replacement Pump DisassemblyShaft Seal Replacement Drive Assembly Removal and Installation Replacement Parts Illustrated Parts ListIntelliFlo Pump Dimensions IntelliFlo 4 Electrical SpecificationsIntelliflo Flow and Power vs Flow Pump Curve Blank Alarm and warning LED sequence TroubleshootingProblem Possible Cause Corrective Action General IntelliFlo 4 Troubleshooting ProblemsActive Problems and Corrective ActionIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B