Pentair 4/160, 4/100 important safety instructions Connecting IntelliFlo to IntelliTouch

Page 20

14

Connecting IntelliFlo to IntelliTouch (Continued)

6.Strip back the cable conductors ¼”. Insert the wires into the either of the COM PORTS (J7 and J8) screw terminals located on the left side of the Personality board. Secure the wires with the screws. For wiring details, refer to the pin configuration shown below. Note: Multiple wires may be inserted into a single screw terminal.

IntelliTouch Personality board COM PORT (J7/J8)

BLK

GRN

YEL

RED

Pin Configuration for IntelliFlo 4 to IntelliTouch:

IntelliFlo 4: Connect pin 6 (green) to IntelliTouch screw terminal pin 2 (green)

IntelliFlo 4: Connect pin 7 (yellow) to IntelliTouch screw terminal pin 3 (yellow)

 

IntelliTouch

 

 

COM PORT (J7/J8)

 

 

screw terminal

 

Pin 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Green)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IntelliTouch

IntelliFlo

Pin 7 (Yellow)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screw terminal

(2-wire cable)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IntelliFlo 4 cable pin configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 (GRN)

GREEN (Pin 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 (YEL)

YELLOW (Pin 7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin configuration

7.Close the IntelliTouch control panel and secure it with the two access screws.

8.Install the high voltage panel cover and secure it with the two retaining screws.

9.Close the load center front door and secure with the two latches.

10.Switch power on to the IntelliTouch load center.

IntelliFlo 4 Installation and User’s Guide

Image 20
Contents IntelliFlo 4/160 and 4/100 Customer Support Moorpark, California 8 A.M. to 5 P.MContents Important Safety Precautions Important NoticeImportant Safety Precautions General Installation Information General WarningsExternal Control IntelliFlo 4 Variable Speed PumpIntelliFlo 4 models IntelliFlo 4 Motor Assembly FeaturesIntelliFlo 4 Drive Assembly and Control Panel IntelliFlo 4 Operator Control Panel Controls and LEDsSetting the pump preset speed Adjusting the pump speedResetting the pump to factory defaults Assigning a pump address for remote controlStarting the pump Stopping the pumpPriming the pump for the first time or after service Disconnect the communication cable from the pumpTop view External Control with IntelliComm Communication Center External ControlConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Connecting IntelliFlo to IntelliTouch Pin Configuration for IntelliFlo 4 to IntelliTouchPump Strainer Basket Service Pump Strainer BasketMotor Service Priming the pump after service WinterizingBlank IntelliFlo 4 Kit Contents Installing the IntelliFloLocation PipingWiring the IntelliFlo Pump Disassembly Shaft Seal Replacement Pump DisassemblyPump Reassembly/Seal Replacement Drive Assembly Removal and Installation Illustrated Parts List Replacement PartsIntelliflo Flow and Power vs Flow Pump Curve IntelliFlo 4 Electrical SpecificationsIntelliFlo Pump Dimensions Blank Troubleshooting Alarm and warning LED sequenceGeneral IntelliFlo 4 Troubleshooting Problems Problem Possible Cause Corrective ActionProblems and Corrective Action ActiveIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B