Pentair 4/160, 4/100 important safety instructions Wiring the IntelliFlo

Page 26

20

Wiring the IntelliFlo 4

To connect the IntelliFlo 4 to an AC power source:

1.Make sure all electrical breakers and switches are turned off before wiring motor.

2.Make sure that the wiring voltage is 230 VAC.

3.Use #12 AWG for wire runs up to 100 feet and #10 AWG for lengths longer than 100 feet. When in doubt use a heavier gauge (larger diameter) wire. Heavier gauge will allow the motor to run cooler and moreefficient.

4.Make sure all electrical connections are clean and tight.

5.Cut the wires to the appropriate length so they do not overlap or touch when connected.

6.Permanently ground the motor using the green ground wire, as shown below. Use the correct wire size and type specified by National Electrical Code. Make sure the ground wire is connected to an electrical serviceground.

7.Bond the motor to the pool structure in accordance with the National Electrical Code. Use a solid No. 8 AWG or larger copper conductor. Run a wire from the external bonding lug to the pool bonding structure, as shown below.

8.The IntelliFlo pump is designed to be permanently connected to its power source. Typically the pump receives power directly from the circuit breaker. No contactor or motor starter is required. The drive controls the starting and stopping of the pump. If the IntelliFlo is connected to an automation system, such as EasyTouch or IntelliComm, the drive must be powered up to receive and respond to the RS-485 serial communication from the automation system. However, the pump can be operated in “stand-alone” mode, starting and stopping when power is applied or removed. When the drive powers up it will return to the mode and run status that it was in when power was removed. This setup maybe appropriate if you need to useexistingrelaysortimers.

9.For wiring pinouts for the communications port, see page 11.

GROUND WIRE (GREEN)

IntelliFlo 4 wiring harness

Red = Hot

Red = Hot

Green/yellow stripe = Ground

BONDING LUG

IntelliFlo 4 Installation and User’s Guide

Image 26
Contents IntelliFlo 4/160 and 4/100 Customer Support Moorpark, California 8 A.M. to 5 P.MContents Important Safety Precautions Important NoticeImportant Safety Precautions General Installation Information General WarningsExternal Control IntelliFlo 4 Variable Speed PumpIntelliFlo 4 models IntelliFlo 4 Motor Assembly FeaturesIntelliFlo 4 Drive Assembly and Control Panel IntelliFlo 4 Operator Control Panel Controls and LEDsSetting the pump preset speed Adjusting the pump speedStarting the pump Resetting the pump to factory defaultsAssigning a pump address for remote control Stopping the pumpPriming the pump for the first time or after service Disconnect the communication cable from the pumpTop view External Control with IntelliComm Communication Center External ControlConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Connecting IntelliFlo to IntelliTouch Pin Configuration for IntelliFlo 4 to IntelliTouchPump Strainer Basket Service Pump Strainer BasketMotor Service Priming the pump after service WinterizingBlank Location IntelliFlo 4 Kit ContentsInstalling the IntelliFlo PipingWiring the IntelliFlo Pump Disassembly Shaft Seal Replacement Pump DisassemblyPump Reassembly/Seal Replacement Drive Assembly Removal and Installation Illustrated Parts List Replacement PartsIntelliflo Flow and Power vs Flow Pump Curve IntelliFlo 4 Electrical SpecificationsIntelliFlo Pump Dimensions Blank Troubleshooting Alarm and warning LED sequenceGeneral IntelliFlo 4 Troubleshooting Problems Problem Possible Cause Corrective ActionProblems and Corrective Action ActiveIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B