Pentair 4/160, 4/100 IntelliFlo 4 Operator Control Panel, Controls and LEDs

Page 10

4

IntelliFlo 4 Operator Control Panel

The IntelliFlo 4 operator control panel provides manual speed controls for the pump. There are four preset speed buttons that can be selected. The Up and Down button is used to adjust the pump speed. The selected speed can be saved and assigned to one of the speed buttons.

1

2

5

6

3 4

Controls and LEDs

1Speed 1, Speed 2, Speed 3, and Speed 4 button/LED: Press one of the speed buttons to select the desired

preset pump speed. The pump preset speeds are: Speed 1 (750 RPM), Speed 2 (1500 RPM), Speed 3 (2350 RPM), and Speed 4 (3110 RPM). The speed button LED is on when the selected button is pressed. If the pump is running and the Up/Down button is used to adjust the speed, the selected speed LEDs will go off. For more about using the speed buttons, see page 5.

2Up/Down button: While the pump is running, press the Up or Down button to increase or decrease the pump speed. To save the new pump speed, press any one of the four speed buttons for three seconds to assign the speed to the selected button (the LED be on). Four adjusted pump speeds can be assigned to the speed buttons. When the pump is using an adjusted speed and the pump is powered down, the next time the pump is powered up the pump will use the same speed. For more about using the Up/Down button, see page 5.

3Start button/LED: Starts the pump using a selected or adjusted speed. This LED is on when the pump is running.

4Stop button: Press this button to stop the pump.

5On LED: This green power LED is on when IntelliFlo 4 is powered up.

6Alarm LED: This LED is on when an error condition occurs. This green LED will flash a certain number of times indicating a specific error condition. For the alarm LED flash sequence, refer to “Alarm and Warning LED Sequence,” on page 27.

IntelliFlo 4 Installation and User’s Guide

Image 10
Contents IntelliFlo 4/160 and 4/100 Customer Support Moorpark, California 8 A.M. to 5 P.MContents Important Safety Precautions Important NoticeImportant Safety Precautions General Installation Information General WarningsIntelliFlo 4 models IntelliFlo 4 Variable Speed PumpExternal Control IntelliFlo 4 Motor Assembly FeaturesIntelliFlo 4 Drive Assembly and Control Panel IntelliFlo 4 Operator Control Panel Controls and LEDsSetting the pump preset speed Adjusting the pump speedStarting the pump Resetting the pump to factory defaultsAssigning a pump address for remote control Stopping the pumpPriming the pump for the first time or after service Disconnect the communication cable from the pumpTop view External Control with IntelliComm Communication Center External ControlConnecting IntelliFlo 4 to an EasyTouch System EasyTouch to IntelliFlo 4 pin configuration IntelliFlo 4 Installation and User’s Guide Connecting IntelliFlo 4 to an IntelliTouch System Connecting IntelliFlo to IntelliTouch Pin Configuration for IntelliFlo 4 to IntelliTouchPump Strainer Basket Service Pump Strainer BasketMotor Service Priming the pump after service WinterizingBlank Location IntelliFlo 4 Kit ContentsInstalling the IntelliFlo PipingWiring the IntelliFlo Pump Disassembly Pump Reassembly/Seal Replacement Pump DisassemblyShaft Seal Replacement Drive Assembly Removal and Installation Illustrated Parts List Replacement PartsIntelliFlo Pump Dimensions IntelliFlo 4 Electrical SpecificationsIntelliflo Flow and Power vs Flow Pump Curve Blank Troubleshooting Alarm and warning LED sequenceGeneral IntelliFlo 4 Troubleshooting Problems Problem Possible Cause Corrective ActionProblems and Corrective Action ActiveIntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide IntelliFlo 4 Installation and User’s Guide Page 357269 Rev B