Heath Zenith SL-6107 manual Installation

Page 2

Some local building codes may require installation by a quali- fied electrician.

INSTALLATION

For your safety, turn off power at the fuse or circuit breaker.

Note: A “3-way” circuit controls lights from two separate switches. If you want to use this product in a single switch circuit or if you want to install more than one motion sensing wall switch, see Special Installations, page 8.

Select a 3-way circuit that controls a light or an outlet to a lamp.

Total lighting must be from 25 to 500 watts incandescent, or 60 to 400 watts fluorescent using a rapid start ballast. Note: May not be used to operate electronic or magnetic ballasts. Less wattage than the minimum may not allow the control to work properly. The switch selected for replacement should be in a place that can detect motion in the desired area.

For easier re-wiring later, mark the house wiring with tape indicating where the wire had been connected.

In the following section you will install a jumper wire at one 3-way switch and replace the other switch with the SL-6107.

*Note: The existing 3-way switch will be referred to as the “Remote Switch” throughout the rest of the installation manual.

- -

595-4514-14

Image 2
Contents Motion Sensing Way Wall Switch Installation ONE SL-6107 Switch in Circuit Add Jumper At Remote 3-Way Switch Connect Jumper at the Remote SwitchReplace Other Switch Turn the power off at the circuit breakerTest For Correct Common Wire Connection Troubleshooting Wiring Connections Turn power off before rewiringSpecial Installations Single Switch InstallationAdjustment Photo SensitivityM E Install Wall Cover PlateTime Control On When you want the light on all the time Using the Light ControlOff When you want the light off all the time OperationsTroubleshooting Auto mode, light does not stay on Technical ServiceNo Service Parts Available for this Product Auto mode, light turns on in daylightSpecifications Five Year Limited Warranty El Interruptor Tridireccional de pared y Dectector de Instalacion 18-595-4514-14 Conecte el Cable Conector en el Interruptor a Control Remoto Instale el Detector de Movimiento en el otro inte- rruptor Prueba para la conexión correcta de un cable común Conexiones de cableado para análisis de averías Apague la energia antes de reconectarInstalaciones Especiales Se muestra aquíAjuste Sensibilidad de FotoControl del Tiempo Instale la Tapa de ParedOff Cuando quiere que la luz esté siempre apagada FuncionamientoCómo usar el Control de Luz On Cuando quiere que la luz esté siempre prendidaLa luz no se apaga Investigacion DE AveriasLa luz no se prende El interruptor a control remoto no funcionaServicio Técnico Especificaciones Hasta 400 Vatios Máximo Estabilizador de arranque rápidoGarantía Limitada a 5 Años 595-4514-14-31 32-595-4514-14
Related manuals
Manual 30 pages 18.36 Kb