Rinnai RC98HPE Flushing the Heat Exchanger Error Code LC or, H2 H1 Circulating Pump, Water Heater

Page 16
Flushing the Heat Exchanger (Error Code: LC or 00)

Flushing the Heat Exchanger (Error Code: LC or 00)

An “LC” or “00” error code indicates the unit is beginning to lime up and must be flushed. Failure to flush the appliance will cause damage to the heat exchanger. Damage caused by lime build-up is not covered by the unit’s warranty. After flushing, reset the LC fault code by turning off the power to the unit and turning the power back on.

1.Disconnect electrical power to the water heater.

2.Close the shutoff valves on both the hot water and cold water lines (V3 and V4).

3.Connect pump outlet hose (H1) to the cold water line at service valve V2.

4.Connect drain hose (H3) to service valve V1.

5.Pour 4 gallons of undiluted virgin, food grade, white vinegar into pail.

6.Place the drain hose (H3) and the hose (H2) to the pump inlet into the cleaning solution.

7.Open both service valves (V1 and V2) on the hot water and cold water lines.

8.Operate the pump and allow the cleaning solution to circulate through the water heater for 1 hour at a rate of 4 gallons per minute (15.1 liters per minute).

9.Turn off the pump.

10.Rinse the cleaning solution from the water heater as follows:

a.Remove the free end of the drain hose (H3) from the pail.

b.Close service valve, (V2), and open shutoff valve, (V4). Do not open shutoff valve, (V3).

c.Allow water to flow through the water heater for 5 minutes

d.Close service valve, (V1), and open shutoff valve, (V3).

11.Disconnect all hoses.

12.With (V4) closed, remove the in-line filter at the cold water inlet and clean out any residue. Place filter back into unit and open (V4).

13.Restore electrical power to the water heater.

KEY

3/4" Ball Valve

Pressure Regulator

 

3/4" Union

Circulating Pump

Check Valve

Boiler Drain Valve

Pressure Relief Valve

S Solenoid Valve

Water Heater

In-line

 

Filter

Gas Supply

 

V1 V2

H3

V4

 

V3

Cleaning solution is 4 gallons of undiluted virgin, food grade, white vinegar.

Cold Water Line Hot Water Line

H2

H1

Circulating Pump

16

Manual - Rinnai Condensing Water Heaters

Image 16
Contents Direct Vent Tankless Water Heater Operation and Installation ManualANS Z21.10.3 Table of Contents Consumer Safety InformationError Codes Technical DataSpecifications RC80HPiRC98HPi RC98HPeConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features DANGERDescription of Operation Features Available on Temperature ControllersOperating Instructions MC-502RC-1US-S* Wireless In Use Indicator Temperature Display TemperaturePriority Indicator Priority Button ON/OFF Button IndicatorIn Use Indicator Temperature Display Clock Call Priority Button and Indicator ON/OFF ButtonBC-100V-1US MC-100V-1USHow to Set the Temperature Temperature Controller SettingsRC80HPi RC80HPeSetting the Sound Volume Voice Prompt Temperature Controller SettingsRe-settingthe Maximum Temperature MCC-91Temperature ControllerSetting the Water Volume Using the Water Smart / Bath Fill FunctionOverview Setting Controller to Mute Setting the ClockUsing the Water Smart / Bath Fill Function Filling the TubMaintenance CleaningVent System Motors Error Codes Fault Code RemedyManual - Rinnai Condensing Water Heaters codeTrouble Shooting for Common Issues Accessing Operating InformationWater Quality I don’t have any hot water when I open the tapH2 H1 Circulating Pump Flushing the Heat Exchanger Error Code LC orWater Heater Installation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGas Piping Electrical ConnectionGeneral Instructions Pipe Sizing Procedure - Example Gas PipingGas Input of Rinnai water heater BTU / HR Cubic Feet per Hour CFH =Water Piping General InstructionsPressure Relief Valve Freeze ProtectionFreeze Protection Piping Condensate drain line Recommended Piping for Basic InstallationCondensate drain Recommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems 3 years on heat exchanger 3 year on partsManual - Rinnai Condensing Water Heaters For this applicationIntake / Exhaust Guidelines Venting InstructionsCondensate Maximum Vent Length Vent ProductsREU-KA2530FFUD-US RC98HPiFlue Terminal Clearances ANS Z21.10.3 CSA AREA WHERE B TERMINAL IS NOT PERMITTTEDCanadian Installations US InstallationsINSIDE CORNER Additional Clearances RC80HPe, RC98HPe IN S ID E C O R N E RFlue Installation RC80HPi, RC98HPi Dispose of condensate per local codesDispose of condensate per local codes Securing Manual - Rinnai Condensing Water HeatersConnecting Multiple Water Heaters High Altitude InstallationsGuidelines Temperature Controller Installation ConfigurationsLocation Cable Lengths and Sizesecuring screw wiring hole securing screw Temperature Controller InstallationMounting the Controller Outline of RemoteFOR YOUR SAFETY READ BEFORE OPERATING Operating InstructionsOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCETechnical Data Pressure Drop CurveOutlet Flow Data Pressure Loss psiSpace Heating Temperature SettingReplacement PumpsDimensions RC80HPi, RC98HPiRC80HPi, RC80HPe RC80HPe, RC98HPeLadder Diagram TWIN THERMISTORLimited Warranty Warranty InformationConsumer Support Limited Warranty Continued How do I get service?What is not covered? What will Rinnai do?Manuel dinstallation et dutilisation ou lappel 1-866-RINNAI1Instructions dutilisation Comportements et pratiques de sécuritéRéglage de température Chaud BrûlureOptions de température sans contrôleur à distance RC80HPiRC80HPe RC98HPiEntretien CORRECT VUE DE FACEINCORRECT VUE DE FACE NettoyageInstructions générales Installation InstructionsNutilisez pas de matériaux de substitution Manuel - Rinnai Condensing Water HeatersFixation du chauffe-eau Écartements par rapport à lappareilRC80HPe, RC98HPe Tuyauterie de gaz Installations à haute altitudeInstructions générales Tuyauterie deau Qualité de leauInstructions générales Soupape de sûretéLégende Tuyauterie recommandée pour installation de baseCondensate Vidange condensat drain Consignes pour aspiration/évacuation Instructions de ventilationCondensat Longueur maximum de ventilation Produits de ventilation RC80HPi ................. REU-KA2530FFUDRC98HPi ................. REU-KA3237FFUD Rinnai/UbbinkInstallations au Canada Installations aux USAENTÉE DALIMENTATION EN AIR TERMINAISON DE VENTILATIONVis de fixation Instructions dutilisation INSTRUCTIONS DE MISE EN MARCHECOMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL FERMÉECLOSE OUVERTOPENDiagramme en escalier CONTACT DEFUSIBLE 7 A DÉTECTION DE GELInformations sur la garantie Support à la clientèleGarantie limitée Garantie limitée Manuel - Rinnai Condensing Water HeatersQue fait Rinnai pour exercer la garantie ? Quest-cequi nest pas couvert ?Rinnai’s other fine products U290-665X01