Rinnai RC98HPI Maximum Vent Length, Vent Products, REU-KA2530FFUD-US, RC98HPi, REU-KA3237FFUD-US

Page 27
Maximum Vent Length

Maximum Vent Length

1.Determine the number of 90 degree elbows in the vent system. Two 45 degree elbows count as one 90 degree elbow.

2.Refer to the table to find the maximum vent length based on the number of elbows.

3.Follow the applicable note.

Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual length is greater than 15 ft (4.6 m) then move dip switch no. 1 (SW1) to OFF.

Number of 90° Elbows

0

1

2

3

4

5

6

 

 

 

 

 

 

 

41 ft 1

35 ft 2

29 ft 3

23 ft 4

17 ft 4

11 ft 4

5 ft 4

(12.5 m)

(10.7 m)

(8.8 m)

(7.0 m)

(5.2 m)

(3.4 m)

(1.5 m)

 

 

 

 

 

 

 

1If the length is greater than 21 ft (6.4 m) then move

dip switch no. 1 (SW1) to OFF.

Notes 1234

 

2If the length is greater than 15 ft (4.6 m) then move dip switch no. 1 (SW1) to OFF.

3If the length is greater than 9 ft (2.7 m) then move dip switch no. 1 (SW1) to OFF.

4Move dip switch no. 1 (SW1) to OFF.

Switch No.

Vent Products ON

O1

F

F 2

3

4

5

6

7

8

Vent Products

 

 

Listed and Tested Vent Products for RC80HPi

REU-KA2530FFUD-US

 

RC98HPi

REU-KA3237FFUD-US

 

 

 

Manufacturer

Product

Parts

 

 

 

Rinnai/Ubbink

Rolux Condensing Vent

 

 

System

Refer to the manufacturer’s technical literature for

Selkirk / Heat-Fab

Saf-T Vent SC system

specific part numbers and instructions.

 

 

Metal-Fab

Corr/Guard Vent/Air

 

 

Intake System

 

 

 

 

Vent Manufacturer Contact Information for Installation Instructions and Parts Lists:

Rinnai/Ubbink

Heat-Fab

 

Metal-Fab Inc.

Telephone: 800-621-9419

Telephone:

800-772-0739

Telephone:

800-835-2830

Fax:

678-829-1666

Fax:

413-863-4803

 

316-943-2351

Web Site:

www.rinnai.us

E-mail:

custsvc@heat-fab.com

Fax:

316-943-2717

 

 

Web Site:

www.heatfab.com

E-mail:

info@mtlfab.com

 

 

 

 

Web Site:

www.metal-fabinc.com

 

 

Manual - Rinnai Condensing Water Heaters

27

Image 27
Contents Operation and Installation Manual Direct Vent Tankless Water HeaterANS Z21.10.3 Technical Data Table of ContentsConsumer Safety Information Error CodesRC98HPe SpecificationsRC80HPi RC98HPiDANGER Consumer Safety InformationSafety Definitions Safety Behavior and Practices Safety FeaturesFeatures Available on Temperature Controllers Description of OperationOperating Instructions Indicator MC-502RC-1US-S* WirelessIn Use Indicator Temperature Display Temperature Priority Indicator Priority Button ON/OFF ButtonMC-100V-1US In Use Indicator Temperature Display Clock CallPriority Button and Indicator ON/OFF Button BC-100V-1USRC80HPe How to Set the TemperatureTemperature Controller Settings RC80HPiMCC-91Temperature Controller Setting the Sound Volume Voice PromptTemperature Controller Settings Re-settingthe Maximum TemperatureUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Filling the Tub Setting Controller to MuteSetting the Clock Using the Water Smart / Bath Fill FunctionMotors MaintenanceCleaning Vent SystemRemedy Error CodesFault Codecode Manual - Rinnai Condensing Water HeatersI don’t have any hot water when I open the tap Trouble Shooting for Common IssuesAccessing Operating Information Water QualityFlushing the Heat Exchanger Error Code LC or H2 H1 Circulating PumpWater Heater General Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Cubic Feet per Hour CFH = Pipe Sizing Procedure - ExampleGas Piping Gas Input of Rinnai water heater BTU / HRFreeze Protection Water PipingGeneral Instructions Pressure Relief ValveFreeze Protection Piping Recommended Piping for Basic Installation Condensate drain lineCondensate drain For this application Recommended Piping for Circulation SystemsFor this application Optional Piping for Circulation Systems3 years on heat exchanger 3 year on parts Manual - Rinnai Condensing Water HeatersVenting Instructions Intake / Exhaust GuidelinesCondensate RC98HPi Maximum Vent LengthVent Products REU-KA2530FFUD-USUS Installations Flue Terminal Clearances ANS Z21.10.3 CSAAREA WHERE B TERMINAL IS NOT PERMITTTED Canadian InstallationsINSIDE CORNER IN S ID E C O R N E R Additional Clearances RC80HPe, RC98HPeManual - Rinnai Condensing Water Heaters Flue Installation RC80HPi, RC98HPiDispose of condensate per local codes Dispose of condensate per local codes SecuringHigh Altitude Installations Connecting Multiple Water HeatersGuidelines Cable Lengths and Size Temperature Controller InstallationConfigurations LocationOutline of Remote securing screw wiring hole securing screwTemperature Controller Installation Mounting the ControllerTO TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions OPERATING INSTRUCTIONSPressure Loss psi Technical DataPressure Drop Curve Outlet Flow DataPumps Space HeatingTemperature Setting ReplacementRC80HPe, RC98HPe DimensionsRC80HPi, RC98HPi RC80HPi, RC80HPeTWIN THERMISTOR Ladder DiagramWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Limited Warranty ContinuedHow do I get service? What is not covered?ou lappel 1-866-RINNAI1 Manuel dinstallation et dutilisationChaud Brûlure Instructions dutilisationComportements et pratiques de sécurité Réglage de températureRC98HPi Options de température sans contrôleur à distanceRC80HPi RC80HPeNettoyage EntretienCORRECT VUE DE FACE INCORRECT VUE DE FACEManuel - Rinnai Condensing Water Heaters Instructions généralesInstallation Instructions Nutilisez pas de matériaux de substitutionÉcartements par rapport à lappareil Fixation du chauffe-eauRC80HPe, RC98HPe Installations à haute altitude Tuyauterie de gazInstructions générales Soupape de sûreté Tuyauterie deauQualité de leau Instructions généralesTuyauterie recommandée pour installation de base LégendeCondensate Vidange condensat drain Instructions de ventilation Consignes pour aspiration/évacuationCondensat Longueur maximum de ventilation Rinnai/Ubbink Produits de ventilationRC80HPi ................. REU-KA2530FFUD RC98HPi ................. REU-KA3237FFUDVENTILATION Installations au CanadaInstallations aux USA ENTÉE DALIMENTATION EN AIR TERMINAISON DEVis de fixation FERMÉECLOSE OUVERTOPEN Instructions dutilisationINSTRUCTIONS DE MISE EN MARCHE COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREILDÉTECTION DE GEL Diagramme en escalierCONTACT DE FUSIBLE 7 ASupport à la clientèle Informations sur la garantieGarantie limitée Quest-cequi nest pas couvert ? Garantie limitéeManuel - Rinnai Condensing Water Heaters Que fait Rinnai pour exercer la garantie ?U290-665X01 Rinnai’s other fine products