Rinnai RC80HPE, RC98HPE, RC80HPI, RC98HPI Clearances from Appliance, Attachment of the Water Heater

Page 18
Clearances from Appliance

Clearances from Appliance

RC80HPi, RC98HPi

 

RC80HPe, RC98HPe

 

 

 

 

 

 

 

 

 

 

to Com-

to Non-

 

 

to Com-

to Non-

 

 

Combus-

 

 

Combus-

 

 

bustibles

 

 

bustibles

 

 

 

tibles

 

 

 

tibles

 

Top of

12 inches

2 inches

 

Top of

12 inches

2 inches

 

Heater

(305 mm)

(51 mm)

 

Heater

(305 mm)

(51 mm)

 

Back of

0 (zero)

0 (zero)

 

Back of

0 (zero)

0 (zero)

 

Heater

 

 

 

Heater

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front of

6 inches

6 inches

 

Front

24 inches

0 inches

to side

Heater

(152 mm)

(152 mm)

 

(Panel)

(610 mm)

(0 mm)

 

Sides of

2 inches

1/2 inch

 

Front

24 inches

24 inches

 

Heater

(51 mm)

(13 mm)

 

(Exhaust)

(610 mm)

(610 mm)

 

Floor/

12 inches

2 inches

 

Sides of

6 inches

1/8 inch

 

Ground

(305 mm)

(51 mm)

 

Heater

(152 mm)

(3.2 mm)

to floor/ground

 

 

 

 

 

 

 

Vent

4 inches *

0 (zero)

 

Floor/

12 inches

2 inches

 

 

 

 

Ground

(305 mm)

(51 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*4 inches (102 mm) for enclosed area; 1 inch (26 mm) for unenclosed area.

**0 inches from vent components and condensate drain line.

The clearance for servicing is 24 inches in front of the water heater.

For closet installation: clearance is 6 inches (152 mm) from the front.

to top

to front

Attachment of the Water Heater

1.Identify the installation location and confirm that the installation will meet all required clearances.

2.Securely attach the water heater to the wall using any of the holes in the wall installation brackets which are at the top and bottom of the water heater. Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specifications section.

wall installation

brackets

18

Manual - Rinnai Condensing Water Heaters

Image 18
Contents Operation and Installation Manual Direct Vent Tankless Water HeaterANS Z21.10.3 Error Codes Table of ContentsConsumer Safety Information Technical DataRC98HPi SpecificationsRC80HPi RC98HPeSafety Behavior and Practices Safety Features Consumer Safety InformationSafety Definitions DANGERFeatures Available on Temperature Controllers Description of OperationOperating Instructions Priority Indicator Priority Button ON/OFF Button MC-502RC-1US-S* WirelessIn Use Indicator Temperature Display Temperature IndicatorBC-100V-1US In Use Indicator Temperature Display Clock CallPriority Button and Indicator ON/OFF Button MC-100V-1USRC80HPi How to Set the TemperatureTemperature Controller Settings RC80HPeRe-settingthe Maximum Temperature Setting the Sound Volume Voice PromptTemperature Controller Settings MCC-91Temperature ControllerUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Using the Water Smart / Bath Fill Function Setting Controller to MuteSetting the Clock Filling the TubVent System MaintenanceCleaning MotorsCode Error CodesFault RemedyManual - Rinnai Condensing Water Heaters codeWater Quality Trouble Shooting for Common IssuesAccessing Operating Information I don’t have any hot water when I open the tapFlushing the Heat Exchanger Error Code LC or H2 H1 Circulating PumpWater Heater Installation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterElectrical Connection Gas PipingGeneral Instructions Gas Input of Rinnai water heater BTU / HR Pipe Sizing Procedure - ExampleGas Piping Cubic Feet per Hour CFH =Pressure Relief Valve Water PipingGeneral Instructions Freeze ProtectionFreeze Protection Piping Recommended Piping for Basic Installation Condensate drain lineCondensate drain Recommended Piping for Circulation Systems For this applicationManual - Rinnai Condensing Water Heaters Optional Piping for Circulation Systems3 years on heat exchanger 3 year on parts For this applicationVenting Instructions Intake / Exhaust GuidelinesCondensate REU-KA2530FFUD-US Maximum Vent LengthVent Products RC98HPiCanadian Installations Flue Terminal Clearances ANS Z21.10.3 CSAAREA WHERE B TERMINAL IS NOT PERMITTTED US InstallationsINSIDE CORNER Additional Clearances RC80HPe, RC98HPe IN S ID E C O R N E RDispose of condensate per local codes Securing Flue Installation RC80HPi, RC98HPiDispose of condensate per local codes Manual - Rinnai Condensing Water HeatersHigh Altitude Installations Connecting Multiple Water HeatersGuidelines Location Temperature Controller InstallationConfigurations Cable Lengths and SizeMounting the Controller securing screw wiring hole securing screwTemperature Controller Installation Outline of RemoteOPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATINGOperating Instructions TO TURN OFF GAS TO APPLIANCEOutlet Flow Data Technical DataPressure Drop Curve Pressure Loss psiReplacement Space HeatingTemperature Setting PumpsRC80HPi, RC80HPe DimensionsRC80HPi, RC98HPi RC80HPe, RC98HPeLadder Diagram TWIN THERMISTORWarranty Information Limited WarrantyConsumer Support What is not covered? Limited Warranty ContinuedHow do I get service? What will Rinnai do?Manuel dinstallation et dutilisation ou lappel 1-866-RINNAI1Réglage de température Instructions dutilisationComportements et pratiques de sécurité Chaud BrûlureRC80HPe Options de température sans contrôleur à distanceRC80HPi RC98HPiINCORRECT VUE DE FACE EntretienCORRECT VUE DE FACE NettoyageNutilisez pas de matériaux de substitution Instructions généralesInstallation Instructions Manuel - Rinnai Condensing Water HeatersÉcartements par rapport à lappareil Fixation du chauffe-eauRC80HPe, RC98HPe Installations à haute altitude Tuyauterie de gazInstructions générales Instructions générales Tuyauterie deauQualité de leau Soupape de sûretéTuyauterie recommandée pour installation de base LégendeCondensate Vidange condensat drain Instructions de ventilation Consignes pour aspiration/évacuationCondensat Longueur maximum de ventilation RC98HPi ................. REU-KA3237FFUD Produits de ventilationRC80HPi ................. REU-KA2530FFUD Rinnai/UbbinkENTÉE DALIMENTATION EN AIR TERMINAISON DE Installations au CanadaInstallations aux USA VENTILATIONVis de fixation COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL Instructions dutilisationINSTRUCTIONS DE MISE EN MARCHE FERMÉECLOSE OUVERTOPENFUSIBLE 7 A Diagramme en escalierCONTACT DE DÉTECTION DE GELSupport à la clientèle Informations sur la garantieGarantie limitée Que fait Rinnai pour exercer la garantie ? Garantie limitéeManuel - Rinnai Condensing Water Heaters Quest-cequi nest pas couvert ?Rinnai’s other fine products U290-665X01