Rinnai RC98HPE How to Set the Temperature, Temperature Controller Settings, RC80HPi, RC80HPe

Page 8
How to Set the Temperature

How to Set the Temperature

1.If the water heater is off, press the ON/OFF button to turn on.

2.Press the “Priority button” on the

temperature controller. The green Priority light will glow indicating that this controller is controlling the temperature and that the Rinnai water heater is ready to supply hot water.

The priority can only be changed while no hot water is running.

3.Press the ▲ or ▼ buttons to obtain the desired temperature setting.

All hot water sources are able to provide water at this temperature setting until it is changed again at this or another temperature controller.

Temperature Controller Settings

This water heater will attempt to provide hot water at the temperature setting even when the water flow is varied or when more than 1 tap is in use. The water heater can deliver water at only one temperature setting at a time. The available temperatures for a given model are provided below.

Model

 

 

 

 

Temperature Settings Available (ºF)

 

 

 

 

RC80HPi

 

 

 

 

 

 

 

 

 

125

130

135

140

150

160

185

RC80HPe

98

100

102

104

106

108

110

115

120

RC98HPi

 

 

 

 

 

 

 

 

 

*

*

*

*

**

**

**

RC98HPe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temp in Celsius ºC

37

38

39

40

41

42

43

46

49

52

54

57

60

66

71

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Manual - Rinnai Condensing Water Heaters

Image 8
Contents ANS Z21.10.3 Operation and Installation ManualDirect Vent Tankless Water Heater Table of Contents Consumer Safety InformationError Codes Technical DataSpecifications RC80HPiRC98HPi RC98HPeConsumer Safety Information Safety DefinitionsSafety Behavior and Practices Safety Features DANGER Operating Instructions Features Available on Temperature Controllers Description of Operation MC-502RC-1US-S* Wireless In Use Indicator Temperature Display TemperaturePriority Indicator Priority Button ON/OFF Button IndicatorIn Use Indicator Temperature Display Clock Call Priority Button and Indicator ON/OFF ButtonBC-100V-1US MC-100V-1USHow to Set the Temperature Temperature Controller SettingsRC80HPi RC80HPeSetting the Sound Volume Voice Prompt Temperature Controller SettingsRe-settingthe Maximum Temperature MCC-91Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Setting Controller to Mute Setting the ClockUsing the Water Smart / Bath Fill Function Filling the TubMaintenance CleaningVent System MotorsError Codes FaultCode RemedyManual - Rinnai Condensing Water Heaters codeTrouble Shooting for Common Issues Accessing Operating InformationWater Quality I don’t have any hot water when I open the tapWater Heater Flushing the Heat Exchanger Error Code LC orH2 H1 Circulating Pump Installation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure - Example Gas PipingGas Input of Rinnai water heater BTU / HR Cubic Feet per Hour CFH =Water Piping General InstructionsPressure Relief Valve Freeze ProtectionFreeze Protection Piping Condensate drain Recommended Piping for Basic InstallationCondensate drain line Recommended Piping for Circulation Systems For this applicationOptional Piping for Circulation Systems 3 years on heat exchanger 3 year on partsManual - Rinnai Condensing Water Heaters For this applicationCondensate Venting InstructionsIntake / Exhaust Guidelines Maximum Vent Length Vent ProductsREU-KA2530FFUD-US RC98HPiFlue Terminal Clearances ANS Z21.10.3 CSA AREA WHERE B TERMINAL IS NOT PERMITTTEDCanadian Installations US InstallationsINSIDE CORNER Additional Clearances RC80HPe, RC98HPe IN S ID E C O R N E RFlue Installation RC80HPi, RC98HPi Dispose of condensate per local codesDispose of condensate per local codes Securing Manual - Rinnai Condensing Water HeatersGuidelines High Altitude InstallationsConnecting Multiple Water Heaters Temperature Controller Installation ConfigurationsLocation Cable Lengths and Sizesecuring screw wiring hole securing screw Temperature Controller InstallationMounting the Controller Outline of RemoteFOR YOUR SAFETY READ BEFORE OPERATING Operating InstructionsOPERATING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCETechnical Data Pressure Drop CurveOutlet Flow Data Pressure Loss psiSpace Heating Temperature SettingReplacement PumpsDimensions RC80HPi, RC98HPiRC80HPi, RC80HPe RC80HPe, RC98HPeLadder Diagram TWIN THERMISTORConsumer Support Warranty InformationLimited Warranty Limited Warranty Continued How do I get service?What is not covered? What will Rinnai do?Manuel dinstallation et dutilisation ou lappel 1-866-RINNAI1Instructions dutilisation Comportements et pratiques de sécuritéRéglage de température Chaud BrûlureOptions de température sans contrôleur à distance RC80HPiRC80HPe RC98HPiEntretien CORRECT VUE DE FACEINCORRECT VUE DE FACE NettoyageInstructions générales Installation InstructionsNutilisez pas de matériaux de substitution Manuel - Rinnai Condensing Water HeatersRC80HPe, RC98HPe Écartements par rapport à lappareilFixation du chauffe-eau Instructions générales Installations à haute altitudeTuyauterie de gaz Tuyauterie deau Qualité de leauInstructions générales Soupape de sûretéCondensate Vidange condensat drain Tuyauterie recommandée pour installation de baseLégende Condensat Instructions de ventilationConsignes pour aspiration/évacuation Longueur maximum de ventilation Produits de ventilation RC80HPi ................. REU-KA2530FFUDRC98HPi ................. REU-KA3237FFUD Rinnai/UbbinkInstallations au Canada Installations aux USAENTÉE DALIMENTATION EN AIR TERMINAISON DE VENTILATIONVis de fixation Instructions dutilisation INSTRUCTIONS DE MISE EN MARCHECOMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL FERMÉECLOSE OUVERTOPENDiagramme en escalier CONTACT DEFUSIBLE 7 A DÉTECTION DE GELGarantie limitée Support à la clientèleInformations sur la garantie Garantie limitée Manuel - Rinnai Condensing Water HeatersQue fait Rinnai pour exercer la garantie ? Quest-cequi nest pas couvert ?Rinnai’s other fine products U290-665X01