Rinnai user manual Technical Details, Infinity 24e

Page 10

TECHNICAL DETAILS

Infinity Model

Infinity 24e

Units

 

 

 

Installation

External

 

 

 

 

Nat Gas Press Low

0.8

mbar

 

 

 

Nat Gas Press High

9.0

mbar

 

 

 

LPG Press Low

1.7

mbar

 

 

 

LPG Press High

22.6

mbar

 

 

 

Height

600

mm

 

 

 

Width

350

mm

 

 

 

Depth

170

mm

 

 

 

Weight

18

kg

 

 

 

Flue System

Forced Exhaust

 

 

 

Temp. Range Controllers

37 - 75

deg C

 

 

 

Temp. Range without

37,40,43,50,

deg C

Controllers

55*,65,75

 

Ignition

Direct Electronic

Ignition

 

 

 

Gas Consumption Low

 

 

 

 

 

Nat Gas

5.8

kW

 

 

 

LPG

5.8

kW

 

 

 

Gas consumption High

 

 

 

 

 

Nat Gas

52

kW

 

 

 

LPG

52

kW

 

 

 

Max Flow raised 33C

18

L/min

 

 

 

Min Operation Flow

2.7**

L/min

 

 

 

Water Pressure Nom.

1.4 - 10

bar

 

 

 

Power Supply

230 V / 50 Hz

 

 

 

Elec. Consumption Standby

6

Watts

(with 1 remote connected)

 

 

Elec. Consumption Run

55

Watts

 

 

 

Elec. Consumption

100

Watts

Anti-frost Heaters On

 

 

* Factory Setting

**Minimum operation flow based on temperature setpoint and inlet conditions.

10

Image 10
Contents Infinity 24e Definition of Standard Use Rinnai UK WarrantyStandard Use Definition of Commercial UseContents Unpacking Rinnai Water Heater Installation Instructions Important InformationInstallation Instructions Positioning Appliance LocationWater Connection Installation Instructions ConnectionsWater Supply Gas ConnectionFlue Requirements Positioning Dimensions Technical Details Infinity 24eFeatures and Benefits Operating Noise Level is Very LOWImportant Information OFF Operation Without Remotes Turn On by opening the hot water tapTemperature Controls General Temperature Controls Installation Universal Temperature ControllerConnecting Three Controllers Connecting One or Two ControllersConnecting Four Controllers Temperature Controls Temperature Controls Operating Using 1 Universal Temperature Controller Adjusting TemperatureUsing hot water Using 2 or more Universal Temperature ControllersSwitching the system on Bathroom temperatures should be no more than 500CUsing 4 Universal Temperature Controllers StepUsing High Temperature Display Controllers Additional safety features To turn off your hot water systemTemperature Controls Information Testing GAS Pressure Setting Propane 1.7 mbar MbarPropane Mbar Dip Switch Positions Explained DIP Switch SettingDip Switches Explained Temperatures Remotes Connected Error Messages Code Fault Remedy DisplayedWith temperature controller fitted Installations with circulation pumpsWithout temperature controller fitted Restarting the Rinnai Water Heater Standard systemWiring Diagram Diagnostic Points Specification Electrical Supply…………………………….…………..……………….230V AC 50Hz 1phPage Service Contact Commissioning Check List