TECHNICAL DETAILS
Infinity Model | Infinity 24e | Units | |
|
|
| |
Installation | External |
| |
|
|
| |
Nat Gas Press Low | 0.8 | mbar | |
|
|
| |
Nat Gas Press High | 9.0 | mbar | |
|
|
| |
LPG Press Low | 1.7 | mbar | |
|
|
| |
LPG Press High | 22.6 | mbar | |
|
|
| |
Height | 600 | mm | |
|
|
| |
Width | 350 | mm | |
|
|
| |
Depth | 170 | mm | |
|
|
| |
Weight | 18 | kg | |
|
|
| |
Flue System | Forced Exhaust | ||
|
|
| |
Temp. Range Controllers | 37 - 75 | deg C | |
|
|
| |
Temp. Range without | 37,40,43,50, | deg C | |
Controllers | 55*,65,75 |
| |
Ignition | Direct Electronic | ||
Ignition |
| ||
|
| ||
Gas Consumption Low |
|
| |
|
|
| |
Nat Gas | 5.8 | kW | |
|
|
| |
LPG | 5.8 | kW | |
|
|
| |
Gas consumption High |
|
| |
|
|
| |
Nat Gas | 52 | kW | |
|
|
| |
LPG | 52 | kW | |
|
|
| |
Max Flow raised 33C | 18 | L/min | |
|
|
| |
Min Operation Flow | 2.7** | L/min | |
|
|
| |
Water Pressure Nom. | 1.4 - 10 | bar | |
|
|
| |
Power Supply | 230 V / 50 Hz | ||
|
|
| |
Elec. Consumption Standby | 6 | Watts | |
(with 1 remote connected) | |||
|
| ||
Elec. Consumption Run | 55 | Watts | |
|
|
| |
Elec. Consumption | 100 | Watts | |
|
|
* Factory Setting
**Minimum operation flow based on temperature setpoint and inlet conditions.