Rinnai 24e user manual Features and Benefits, Operating Noise Level is Very LOW

Page 11

FEATURES AND BENEFITS

Congratulations on purchasing the Technologically Advanced, Temperature Controlled, Rinnai Hot Water System.

The Rinnai Infinity 24e NEVER RUNS OUT of hot water. As long as electricity, water, and gas supplies are connected, hot water is available when hot water taps are open.

Built into the main micro-processor is the facility to LIMIT THE MAXIMUM TEMPERATURE of the hot water supplied. The water temperature may be limited to various maximum temperatures. This is particularly useful when the hot water unit is installed where young children or the infirm may be using the hot water. The Infinity 24e is delivered with a preset temperature of 550C. If required, the temperature limits can be changed by an authorised person. For further information, please contact Rinnai.

The Rinnai Infinity external unit is a powered flue appliance. This makes it COMPACT, saving both floor and wall space.

The temperature of outgoing hot water is CONSTANTLY MONITORED by a BUILT- IN SENSOR. If the temperature of the outgoing hot water rises to more than 3°C above the selected temperature the burner is shut OFF and only turned ON again when the temperature falls to below the selected temperature.

The burner lights automatically when the hot water tap is opened, and distinguishes when the tap is closed. IGNITION IS ELECTRONIC, so there is no pilot light. When the hot water tap is off, no gas is used.

Up to three temperature controllers can be mounted remotely from the heater. This offers the following additional features:

Localised temperature setting. Diagnostic message.

‘Deluxe’ Temperature Controllers are an optional extra. These provide functions including Bath Fill, Voice Prompt, and Clock Setting.

Temperatures selected at the controllers are retained in the SYSTEM MEMORY.

Operating NOISE LEVEL IS VERY LOW.

ERROR MESSAGES ARE DISPLAYED on the Temperature Controllers, assisting with service.

FROST PROTECTION device built in as standard.

11

Image 11
Contents Infinity 24e Definition of Commercial Use Rinnai UK WarrantyStandard Use Definition of Standard UseContents Unpacking Rinnai Water Heater Important Information Installation InstructionsAppliance Location Installation Instructions PositioningGas Connection Installation Instructions ConnectionsWater Supply Water ConnectionFlue Requirements Positioning Dimensions Infinity 24e Technical DetailsOperating Noise Level is Very LOW Features and BenefitsImportant Information OFF Turn On by opening the hot water tap Operation Without RemotesTemperature Controls General Universal Temperature Controller Temperature Controls InstallationConnecting Four Controllers Connecting One or Two ControllersConnecting Three Controllers Temperature Controls Temperature Controls Operating Adjusting Temperature Using 1 Universal Temperature ControllerBathroom temperatures should be no more than 500C Using 2 or more Universal Temperature ControllersSwitching the system on Using hot waterStep Using 4 Universal Temperature ControllersUsing High Temperature Display Controllers To turn off your hot water system Additional safety featuresTemperature Controls Information Testing GAS Pressure Setting Propane Mbar MbarPropane 1.7 mbar Dip Switches Explained DIP Switch SettingDip Switch Positions Explained Temperatures Remotes Connected Code Fault Remedy Displayed Error MessagesWithout temperature controller fitted Installations with circulation pumpsWith temperature controller fitted Standard system Restarting the Rinnai Water HeaterWiring Diagram Diagnostic Points Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph SpecificationPage Service Contact Commissioning Check List