Rinnai 24e user manual Connecting One or Two Controllers, Connecting Three Controllers

Page 17

TEMPERATURE CONTROLS - INSTALLATION

Connecting One or Two Controllers

1.Isolate the power supply.

2.Remove the front cover from the Appliance (4 screws) fig. 1.

3.Thread the cable through the cable access hole at the base of the appliance.

4.Connect the spade connectors to the terminals marked "Remote Control" on the printed circuit board (fig.2). Polarity is not important. Either wire colour can be connected to either terminal.

5.Replace cover of the Appliance. Ensure that the special earth screw is placed at the bottom right hand corner for earthing purposes.

Connecting Three Controllers

1.Isolate the power supply.

2.Remove the front cover from the Appliance (4 screws) fig.1.

3.Thread the cables through the cable access hole at the base of the appliance.

4.Cut the spade connectors from two controller cables (4 connectors should be cut off) and discard. Connect the wires and terminate into two new spade connectors as shown in fig. 3.

5.Thread the 3 cables through the cable access hole at the base of the appliance. Connect the 4 spade connectors to the terminals marked “Remote Control" on the printed circuit board (fig.2). Polarity is not important. Either wire colour can be connected to either terminal.

6.Replace cover of the Appliance. Ensure that the special earth screw is placed at the bottom right hand corner for earthing purposes.

Connecting Four Controllers

1.Isolate the power supply.

2.Remove the front cover from the Appliance (4 screws) fig.1.

3.Cut the spade connectors from all four controller cables to be connected to the appliance (8 connectors should be cut off) and discard. Connect the wires from two remotes and terminate into two new spade connectors as shown in fig. 3.

4.Repeat for remaining two remotes.

5.Thread the 4 cables through the cable access hole at the base of the appliance. Connect the 4 spade connectors to the terminals marked “Remote Control" on the printed circuit board (fig.2). Polarity is not important. Either wire

colour can be connected to either terminal.

5.Replace cover of the Appliance. Ensure that the special earth screw is placed at the bottom right hand corner for earthing purposes.

17

Image 17
Contents Infinity 24e Standard Use Rinnai UK WarrantyDefinition of Standard Use Definition of Commercial UseContents Unpacking Rinnai Water Heater Important Information Installation InstructionsAppliance Location Installation Instructions PositioningWater Supply Installation Instructions ConnectionsWater Connection Gas ConnectionFlue Requirements Positioning Dimensions Infinity 24e Technical DetailsOperating Noise Level is Very LOW Features and BenefitsImportant Information OFF Turn On by opening the hot water tap Operation Without RemotesTemperature Controls General Universal Temperature Controller Temperature Controls InstallationConnecting Four Controllers Connecting One or Two ControllersConnecting Three Controllers Temperature Controls Temperature Controls Operating Adjusting Temperature Using 1 Universal Temperature ControllerSwitching the system on Using 2 or more Universal Temperature ControllersUsing hot water Bathroom temperatures should be no more than 500CStep Using 4 Universal Temperature ControllersUsing High Temperature Display Controllers To turn off your hot water system Additional safety featuresTemperature Controls Information Testing GAS Pressure Setting Propane Mbar MbarPropane 1.7 mbar Dip Switches Explained DIP Switch SettingDip Switch Positions Explained Temperatures Remotes Connected Code Fault Remedy Displayed Error MessagesWithout temperature controller fitted Installations with circulation pumpsWith temperature controller fitted Standard system Restarting the Rinnai Water HeaterWiring Diagram Diagnostic Points Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph SpecificationPage Service Contact Commissioning Check List