Rinnai Understanding DIP Switch Settings for Temperature Control

Page 30

DIP SWITCH SETTING

Temperatures - Remotes Connected

off on SWI off on SWI off on SWI off on SWI

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

8

8

8

8

40 deg C

43 deg C

50 deg C

55 deg C

off on SWI

4

5

6

7

8

60 deg C

off on SWI

4

5

6

7

8

65 deg C

off on SWI

4

5

6

7

8

75 deg C

Temperatures - Remotes Not Connected

off on SWI off on SWI off on SWI off on SWI

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

8

8

8

8

40 deg C

43 deg C

50 deg C

55 deg C

off on SWI off on SWI off on SWI off on SWI

4

4

4

4

5

5

5

5

6

6

6

6

7

7

7

7

8

8

8

8

60 deg C

65 deg C

75 deg C

85 deg C

30

Image 30
Contents Infinity 24e Definition of Standard Use Rinnai UK WarrantyStandard Use Definition of Commercial UseContents Unpacking Rinnai Water Heater Installation Instructions Important InformationInstallation Instructions Positioning Appliance LocationWater Connection Installation Instructions ConnectionsWater Supply Gas ConnectionFlue Requirements Positioning Dimensions Technical Details Infinity 24eFeatures and Benefits Operating Noise Level is Very LOWImportant Information OFF Operation Without Remotes Turn On by opening the hot water tapTemperature Controls General Temperature Controls Installation Universal Temperature ControllerConnecting One or Two Controllers Connecting Three ControllersConnecting Four Controllers Temperature Controls Temperature Controls Operating Using 1 Universal Temperature Controller Adjusting TemperatureUsing hot water Using 2 or more Universal Temperature ControllersSwitching the system on Bathroom temperatures should be no more than 500CUsing 4 Universal Temperature Controllers StepUsing High Temperature Display Controllers Additional safety features To turn off your hot water systemTemperature Controls Information Testing GAS Pressure Setting Mbar Propane 1.7 mbarPropane Mbar DIP Switch Setting Dip Switch Positions ExplainedDip Switches Explained Temperatures Remotes Connected Error Messages Code Fault Remedy DisplayedInstallations with circulation pumps With temperature controller fittedWithout temperature controller fitted Restarting the Rinnai Water Heater Standard systemWiring Diagram Diagnostic Points Specification Electrical Supply…………………………….…………..……………….230V AC 50Hz 1phPage Service Contact Commissioning Check List