Rinnai 24e user manual GAS Pressure Setting

Page 27

GAS PRESSURE SETTING

The working gas pressure on the water heater is electronically controlled and factory set. Under normal circumstances it does not require adjustment during installation. Perform this procedure only if the unit is not operating correctly and all other possible causes for incorrect operation have been eliminated. Contact Rinnai UK before

attempting to alter the gas pressure. Failure to do so could void the warranty.

1.

Turn 'OFF' the gas supply.

 

 

 

 

2.

Turn 'OFF' 230V power supply.

 

 

 

 

3.

Remove the front cover from the appliance.

 

 

4.

Check gas type switch no.1 of SW1 (fig. 1) is

 

 

 

in the correct position for the type of gas (Nat.

 

 

or LPG) you are using. (SW1 is top set of

 

 

 

switches.)

 

 

 

 

 

 

5.

Attach pressure gauge to burner test point. (fig. 2)

(fig 1)

off on SW1

 

off

on SW1

 

 

 

 

 

 

 

 

 

 

1

-Nat. Gas

 

 

1

-LPG

 

 

 

 

2

 

 

 

2

 

 

 

 

 

3

 

 

 

3

 

 

 

 

 

4

 

 

 

4

 

 

 

 

 

5

 

 

 

5

 

 

 

 

 

6

 

 

 

6

 

 

 

 

 

7

 

 

 

7

 

 

 

 

 

8

 

 

 

8

 

 

6.Turn 'ON' the gas supply.

7.Turn 'ON' 230V power supply.

8.If remote controllers are fitted, turn the unit 'ON' at the master controller, select the maximum delivery temperature and open a hot water tap fully. (CAUTION: Ensure building occupants do not have access to hot water outlets during this procedure.)

9.Set the appliance to 'Forced Low' combustion by setting No. 2 dipswitch of the bottom set of dip switches (SW2) to 'ON'. (fig 3)

10.Check the burner test point operating pressure.

27

Forced Low

off on SW2

1

2 3

(fig 3)

LEGEND:

Black Section indicates position of dip switch.

OFF ON OFF ON

OFF ON

Image 27
Contents Infinity 24e Definition of Commercial Use Rinnai UK WarrantyStandard Use Definition of Standard UseContents Unpacking Rinnai Water Heater Important Information Installation InstructionsAppliance Location Installation Instructions PositioningGas Connection Installation Instructions ConnectionsWater Supply Water ConnectionFlue Requirements Positioning Dimensions Infinity 24e Technical DetailsOperating Noise Level is Very LOW Features and BenefitsImportant Information OFF Turn On by opening the hot water tap Operation Without RemotesTemperature Controls General Universal Temperature Controller Temperature Controls InstallationConnecting One or Two Controllers Connecting Three ControllersConnecting Four Controllers Temperature Controls Temperature Controls Operating Adjusting Temperature Using 1 Universal Temperature ControllerBathroom temperatures should be no more than 500C Using 2 or more Universal Temperature ControllersSwitching the system on Using hot waterStep Using 4 Universal Temperature ControllersUsing High Temperature Display Controllers To turn off your hot water system Additional safety featuresTemperature Controls Information Testing GAS Pressure Setting Mbar Propane 1.7 mbarPropane Mbar DIP Switch Setting Dip Switch Positions ExplainedDip Switches Explained Temperatures Remotes Connected Code Fault Remedy Displayed Error MessagesInstallations with circulation pumps With temperature controller fittedWithout temperature controller fitted Standard system Restarting the Rinnai Water HeaterWiring Diagram Diagnostic Points Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph SpecificationPage Service Contact Commissioning Check List