Rinnai 24e Rinnai UK Warranty, Definition of Standard Use, Definition of Commercial Use

Page 2

RINNAI UK WARRANTY

As the purchaser of this high quality Rinnai Water Heater you are provided with the following conditional guarantee.

 

Heat Exchanger

All Other Parts

 

Parts

Labour

Parts

Labour

 

 

 

 

 

Standard Use

3 Years

1 Year

3 Years

1 Year

24e

 

 

 

 

 

 

 

 

 

Commercial Use

1 Year

1 Year

1 Year

1 Year

24e

 

 

 

 

 

 

 

 

 

Definition of Standard Use.

The warranty period allocated under Standard Use is based on Domestic and Light Commercial hot water usage. Rinnai Standard Use warranty periods apply only where Rinnai water heaters are installed in domestic and light commercial situations at operating temperatures below 650C and do not include installations incorporating storage cylinders or building flow and return systems.

The warranty shall apply to any Rinnai water heater from the Infinity range used in this way.

Definition of Commercial Use.

The warranty period allocated under Commercial Use are for Infinity water heaters installed at premises such as commercial and industrial buildings, cafes, caravan parks, and sporting complexes. Commercial Use warranty applies to:

Water heaters supplying a central shower block

Water heaters supplying kitchens used for the bulk preparation of food. Water heaters set to 650C or higher.

Water heaters used in commercial or industrial processes.

Any application that uses Rinnai water heaters in conjunction with storage tanks

Any application that uses Rinnai water heaters in conjunction with a flow / return system. Water heaters installed as components of centralised bulk hot water systems.

Rinnai Infinity units used in Commercial Situations are only subject to a 1 year warranty across the board. Commercial situations should be supplied by the Rinnai HD range.

No Rinnai warranty will cover faults arising from improper installation or gas supply, water contaminants beyond defined limits, environmental factors, plumbing fittings, or other outside influences of which Rinnai is not responsible. Service calls for these issues will be chargeable.

Description

pH

Total Dissolved

Total Hard-

Chlorides

Magnesium

Calcium

Sodium

Iron

Solids (TDS)

ness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Recom-

6.5 - 9.0

600 mg/litre

200 mg/litre

300 mg/litre

10 mg/litre

20 mg/litre

150 mg/litre

1 mg/litre

mended Levels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Image 2
Contents Infinity 24e Definition of Standard Use Rinnai UK WarrantyStandard Use Definition of Commercial UseContents Unpacking Rinnai Water Heater Installation Instructions Important InformationInstallation Instructions Positioning Appliance LocationWater Connection Installation Instructions ConnectionsWater Supply Gas ConnectionFlue Requirements Positioning Dimensions Technical Details Infinity 24eFeatures and Benefits Operating Noise Level is Very LOWImportant Information OFF Operation Without Remotes Turn On by opening the hot water tapTemperature Controls General Temperature Controls Installation Universal Temperature ControllerConnecting Four Controllers Connecting One or Two ControllersConnecting Three Controllers Temperature Controls Temperature Controls Operating Using 1 Universal Temperature Controller Adjusting TemperatureUsing hot water Using 2 or more Universal Temperature ControllersSwitching the system on Bathroom temperatures should be no more than 500CUsing 4 Universal Temperature Controllers StepUsing High Temperature Display Controllers Additional safety features To turn off your hot water systemTemperature Controls Information Testing GAS Pressure Setting Propane Mbar MbarPropane 1.7 mbar Dip Switches Explained DIP Switch SettingDip Switch Positions Explained Temperatures Remotes Connected Error Messages Code Fault Remedy DisplayedWithout temperature controller fitted Installations with circulation pumpsWith temperature controller fitted Restarting the Rinnai Water Heater Standard systemWiring Diagram Diagnostic Points Specification Electrical Supply…………………………….…………..……………….230V AC 50Hz 1phPage Service Contact Commissioning Check List