Rinnai 24e user manual Temperature Controls

Page 18

TEMPERATURE CONTROLS

The purpose of a Temperature Controller is to enable the user to have complete control over the hot water supply. Used correctly, the hot water unit will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used. Adjustments to the operation of your hot water unit can be made with any of the Temperature Controllers. Each Temperature Controller can be individually programmed.

Up to four Universal and Deluxe Temperature Controllers can be fitted with the Infinity 24e. Universal Controllers allow temperature selection only and come as standard with the water heaters. Deluxe Temperature Controllers are an optional extra. These controllers have temperature selection, bath fill, voice recognition, and time clock functions. When more than one Universal Controller is used one may be set as the Master Controller to allow higher temperatures.

Various water temperatures (°C) can be selected as follows:

Universal Controller:

37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 500C

Master Universal Controller:

37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55, 60, 65°C

Deluxe Bathroom Controller:

Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50°C

Bath fill Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48°C

Deluxe Kitchen Controller:

37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55, 60, 65°C

If a temperature 43°C or higher is selected on any controller and this temperature is then decreased to below 43°C and increased again whilst the water is running, the maximum selectable temperature will become 43°C. This provides additional safety for the consumer.

Suggested temperatures are:

Kitchen 50°C - 65°C*; Shower 39°C - 43°C; Bath fill 39°C - 45°C * This temperature may not be available on all installations.

These temperatures are suggested starting points for selection. You may find higher or lower temperatures are more comfortable. Maintaining lower temperatures helps to save energy. To obtain water temperatures lower than 37°C simply add cold water.

Up to four controllers can be used for one Infinity 24e. When multiple temperature controllers are used they allow the temperature to be set from various locations by pushing the transfer button which gives that controller priority over the system. The temperature selected by the controller with priority will be available to all outlets.

18

Image 18
Contents Infinity 24e Definition of Standard Use Rinnai UK WarrantyStandard Use Definition of Commercial UseContents Unpacking Rinnai Water Heater Installation Instructions Important InformationInstallation Instructions Positioning Appliance LocationWater Connection Installation Instructions ConnectionsWater Supply Gas ConnectionFlue Requirements Positioning Dimensions Technical Details Infinity 24eFeatures and Benefits Operating Noise Level is Very LOWImportant Information OFF Operation Without Remotes Turn On by opening the hot water tapTemperature Controls General Temperature Controls Installation Universal Temperature ControllerConnecting One or Two Controllers Connecting Three ControllersConnecting Four Controllers Temperature Controls Temperature Controls Operating Using 1 Universal Temperature Controller Adjusting TemperatureUsing hot water Using 2 or more Universal Temperature ControllersSwitching the system on Bathroom temperatures should be no more than 500CUsing 4 Universal Temperature Controllers StepUsing High Temperature Display Controllers Additional safety features To turn off your hot water systemTemperature Controls Information Testing GAS Pressure Setting Mbar Propane 1.7 mbarPropane Mbar DIP Switch Setting Dip Switch Positions ExplainedDip Switches Explained Temperatures Remotes Connected Error Messages Code Fault Remedy DisplayedInstallations with circulation pumps With temperature controller fittedWithout temperature controller fitted Restarting the Rinnai Water Heater Standard systemWiring Diagram Diagnostic Points Specification Electrical Supply…………………………….…………..……………….230V AC 50Hz 1phPage Service Contact Commissioning Check List