Rinnai 24e user manual Specification, Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph

Page 36

SPECIFICATION

Model………………………………………………..…....………………………..Infinity 24e

Installation…………………………………………...………...……. External location only

Fuel…………………………………………………..….……………...Natural Gas or LPG *

Control………………………………………………….……………...……….…..Modulating

Input……………………………………………………..………….……………....5.8 to 52 kW

Exhaust type………………………………………..……..Forced Draught Direct Exhaust

Ignition………………………………………………...…………….…………...…..Electronic

Burner……………………………………………………...…………………...Stainless steel

Weight…………………………………………………...……….……………..…..………18kg

Water flow rate ………………………………………..……………….…...2.4** to 24L/min

Minimum operating water pressure…………………..……….…………..……….1.4 Bar

Connections

Gas…………………………………………………………...….………………….…….3/4BSP

Water Inlet………………………………………….………...…………………….……3/4BSP

Water outlet…………………………………….………...………………………….…..3/4BSP

Electrical Supply…………………………….…………..……………….230V AC 50Hz 1ph

*Separate models available for Natural gas or LPG fuel.

**Minimum flow rate based on temperature setpoint and inlet conditions.

Rinnai are continually updating and improving products and reserve the right to alter model specifications without prior notice.

36

Image 36
Contents Infinity 24e Rinnai UK Warranty Standard UseDefinition of Standard Use Definition of Commercial UseContents Unpacking Rinnai Water Heater Installation Instructions Important InformationInstallation Instructions Positioning Appliance LocationInstallation Instructions Connections Water SupplyWater Connection Gas ConnectionFlue Requirements Positioning Dimensions Technical Details Infinity 24eFeatures and Benefits Operating Noise Level is Very LOWImportant Information OFF Operation Without Remotes Turn On by opening the hot water tapTemperature Controls General Temperature Controls Installation Universal Temperature ControllerConnecting One or Two Controllers Connecting Three ControllersConnecting Four Controllers Temperature Controls Temperature Controls Operating Using 1 Universal Temperature Controller Adjusting TemperatureUsing 2 or more Universal Temperature Controllers Switching the system onUsing hot water Bathroom temperatures should be no more than 500CUsing 4 Universal Temperature Controllers StepUsing High Temperature Display Controllers Additional safety features To turn off your hot water systemTemperature Controls Information Testing GAS Pressure Setting Mbar Propane 1.7 mbarPropane Mbar DIP Switch Setting Dip Switch Positions ExplainedDip Switches Explained Temperatures Remotes Connected Error Messages Code Fault Remedy DisplayedInstallations with circulation pumps With temperature controller fittedWithout temperature controller fitted Restarting the Rinnai Water Heater Standard systemWiring Diagram Diagnostic Points Specification Electrical Supply…………………………….…………..……………….230V AC 50Hz 1phPage Service Contact Commissioning Check List