FLUE REQUIREMENTS - POSITIONING
Dimension | Terminal Position | Distance | |
|
|
| |
A | Directly below an opening, air brick, opening windows, etc. | 300mm | |
|
|
| |
B | Above an opening, air brick , opening window, etc. | 300mm | |
|
|
| |
C | Horizontally to an opening, air brick , opening window, etc. | 300mm | |
|
|
| |
D | Below gutters, soil pipes or drain pipes. | 75mm | |
|
|
| |
E | Below eaves. | 200mm | |
|
|
| |
F | Below balconies or car port roof. | 200mm | |
|
|
| |
G | From a vertical drain pipe or soil pipe. | 150mm | |
|
|
| |
H | From an internal or external corner. | 200mm | |
|
|
| |
I | Above ground, roof or balcony level. | 300mm | |
|
|
| |
J | From a surface facing the terminal. | 600mm | |
|
|
| |
K | From a terminal facing a terminal | 1200mm | |
|
|
| |
L | From an opening in a car port. ( e.g. door, window) into a dwell- | 1200mm | |
ing | |||
|
| ||
M | Vertically from a terminal on the same wall. | 1500mm | |
|
|
| |
N | Horizontally from a terminal on the same wall. | 300mm | |
|
|
| |
O | From the wall on which the terminal is mounted | N/A | |
|
|
| |
P | From a vertical structure on the roof. | N/A | |
|
|
| |
Q | Above an intersection with roof. | N/A | |
|
|
| |
| 8 |
|