SERVICING INSTRUCTIONS

REPLACING PARTS

10.GAS VALVE

10.1To change the gas valve:

Remove the control assembly, Section 7

Release the gas inlet pipe, Diagram 18, Arrow A

Remove the thermocouple from the interrupter block

and release the second thermo current cables

Release the pilot pipe, Diagram 18, B

Release the injector feed pipe, Diagram 18, C

Remove the wire cable, Diagram18, D

Remove the two screws

The valve can now be freed.

18

B

 

A

C

D

AR1873

 

11.magnetic safety valve

11.1To replace the magnetic safety valve:

Undo the thermocouple from the interrupter block and remove the two thermo current cables

Unscrew the interrupter block from the back of the valve

Undo the silver magnetic valve retaining but on the back of the valve.

Gently tap out the mag valve

Replace with a new unit

Reassemble in reverse order

12.CONTROL BOX

Remove the two thermo current cables by removing the two screws, Diagram 19

Remove the ignition lead, Diagram 19

Remove the eight loom wire from the control box,

Diagram 19

19

Eight wire

 

cable

 

Thermo current

cables

Ignition lead

Touch pad extension cable

Battery extension cable

AR1915

Remove the battery extension cable, Diagram 19

Remove the touch pad extension cable

The control box can now be replaced.

After replacing the control box you may need to reprogram the handset:

Press and hold the reset button on the control box until you hear two signals. After the second longer signal:

Release the reset button and within 20 seconds

Press the DOWN button on the handset until you hear an additional long signal confirming the new code

29

Image 29
Contents Studio Studio 1 Balanced flue Studio 2 Balanced flue Covering the Following Model8701BFCHEC P8701BFCHECFLUE CHECK APPLIANCE COMMISSIONING CHECKLISTFail GAS CHECKUser Instructions MAN ModeGeneral Lighting the StudioTouch PAD Control Changing the Studio Batteries Cleaning the StudioEmergency Shut OFF All modelsFire will not Light Arrangement of Fuel BEDHOT SURFACES Technical Specification Installation InstructionsCovering the Following Models Studio 1 BF Studio 2 BFStudio 1BF Studio 2BF Packing ChecklistQty Description Fixing Kit containing 850 1050 524 740 940 414 Steel Frame Dimensions Studio836 1036 510 740 940 414 12.5 Flue and Chimney Requirements SITE REQUIREMENTSStudio 2 BF Flue Options Studio 1 BFTOP Flue UP & OUT KIT TOP Flue UP & OUT with Additional BendTOP Flue Vertical Offset KIT 8530/8530AN TOP Flue Vertical KIT 8524/8524ANExtra Flue Lengths GAS SupplySafety Precautions SITE REQUIREMENTS/INSTALLATIONInstallation of the appliance Appliance LocationStud Work Installation Method 1 Frame InstallationStud Work Installation Wall plate Stud Work Installation Method 2 Edge Flue AssemblyMethod 1 Frame only Add 10 mm to the outlet end Assembling the ApplianceLighting the Studio Thermostatic Remote ControlInstallation Instructions Commissioning CommissioningSymptom Cause Remedy Servicing / Fault Finding ChartsServicing Instructions Servicing RequirementsFlame Failure Functional Check Ignition Functional CheckWindow Frame Assembly Replacing PartsGeneral Decorative FrameMaIN Burner Glass WindowBlack Enamelled Panels Ensure no stone pebbles fall into the pilot area MaIN Control AssemblyIgnition Lead Pilot Unit AssemblyControl BOX Magnetic safety valveGAS Valve Main injector Pressure and Leak Testing the AppliancePrimary Aeration Plate Changing between Gas TypesComponent ShoRt Spares ListStudio 1 BF Studio 2 BF Service Records Member of the Stovax Group