USER INSTRUCTIONS

DECREASING TEMPERATURE

Press the DOWN arrow once to decrease flame height one stage

Press and hold the DOWN arrow to decrease to minimum

At the lowest point the fire goes to ‘standby mode’ (only pilot lit)

NOTE: While pressing a button a symbol indicating transmission appears on the display. The receiver confirms transmission with an acoustic signal.

Turning the Studio Off

Press the Off button to extinguish the pilot

2.3TEMP MODE

The display shows the current room temperature. To increase or decrease the fire’s output:

Press the SET button to select either the DAY TEMP or the NIGHT TEMP mode by briefly pressing the SET button

Hold the SET button until the TEMP display flashes and then let go

Set the desired temperature with the UP and DOWN arrows. (Minimum temperature 5C, maximum 30C or

fahrenheit)

Press the OFF button to stop the display flashing or wait to return to TEMP mode.

NOTE: If you set a temperature that is beneath the current room temperature, the fire automatically switches to OFF.

NOTE: If you would like the Night temperature control to turn off then decrease the temperature until [---] is displayed.

2.4TIMER MODE

There are two programmable settings you can make over a 24 hour period, P1 and P2

P1 + = Start Timed Setting 1

P1 + = End of Timed Setting 1

P2 + = Start Timed Setting 2

P2 + = End of Timed Setting 2

2.4.1P1 - Program 1 for a Timed Setting

Press the SET button until the TIMER mode is displayed

Hold the SET button. The displays flashes the current time for P1. While the time displayed is flashing you can alter the hours and minutes set.

To set the time your fire first lights, change the Start Timed Setting for P1 .

Press the UP arrow to alter the hour

Press the DOWN arrow to alter the minutes in 10 minute increments

Press SET again to move to the End of Timed Setting,

P1. The display shows the current setting for P1 This is the time your Studio first shuts down:

Press the UP arrow to alter the hour

Press the DOWN arrow to alter the minutes

2.4.2P2 - Program 2 for a Timed Setting

Use the same steps outlined in 2.4.1 to change the setting for P2.

If you have already set P1 and want to alter the setting for

P2 only:

Press the SET button until TIMER mode is displayed

Hold the SET button until the display flashes the current time for P1

Press the SET button again to scroll past the settings for

P1 and P1

With the time still flashing:

Press the UP arrow to alter the hour

Press the DOWN arrow to alter the minutes

Once all four times are set press the OFF button or simply wait to complete programming.

2.5LOW BATTERY

“BATT” is displayed on the remote when its batteries need replacement.

2.6SETTING THE TIME

Simultaneously press the up and down arrow buttons

Press the up arrow to set the hour and the down arrow to set the minutes

Press OFF to return to the manual mode or simply wait

2.7SETTING THE °C/24 HOUR OR °F/12 HOUR CLOCK

Press OFF and the down arrow until the display changes from °C/24 hour clock to °F/12 hour clock and vice versa.

If the remote is removed, lost or damaged, signals transmitted to the receiver cease. Your fire will go to standby (pilot) mode after 6 hours.

TOUCH PAD CONTROL

6

AR1887

Press the ON-OFF button to light the appliance, (up to

30 seconds)

Press the UP button to increase the flame height

Press the DOWN button to decrease the flame height. At the lowest point it goes to ‘standby mode’, (only pilot

lit)

5

Image 5
Contents Studio Studio 1 Balanced flue Studio 2 Balanced flue Covering the Following Model8701BFCHEC P8701BFCHECFLUE CHECK APPLIANCE COMMISSIONING CHECKLISTFail GAS CHECKUser Instructions MAN ModeGeneral Lighting the StudioTouch PAD Control Changing the Studio Batteries Cleaning the StudioEmergency Shut OFF All modelsFire will not Light Arrangement of Fuel BEDHOT SURFACES Technical Specification Installation InstructionsCovering the Following Models Studio 1 BF Studio 2 BFStudio 1BF Studio 2BF Packing ChecklistQty Description Fixing Kit containing 850 1050 524 740 940 414 Steel Frame Dimensions Studio836 1036 510 740 940 414 12.5 Flue and Chimney Requirements SITE REQUIREMENTSStudio 2 BF Flue Options Studio 1 BFTOP Flue UP & OUT KIT TOP Flue UP & OUT with Additional BendTOP Flue Vertical Offset KIT 8530/8530AN TOP Flue Vertical KIT 8524/8524ANExtra Flue Lengths GAS SupplySafety Precautions SITE REQUIREMENTS/INSTALLATIONInstallation of the appliance Appliance LocationStud Work Installation Method 1 Frame InstallationStud Work Installation Wall plate Stud Work Installation Method 2 Edge Flue AssemblyMethod 1 Frame only Add 10 mm to the outlet end Assembling the ApplianceLighting the Studio Thermostatic Remote ControlInstallation Instructions Commissioning CommissioningSymptom Cause Remedy Servicing / Fault Finding ChartsServicing Instructions Servicing RequirementsFlame Failure Functional Check Ignition Functional CheckWindow Frame Assembly Replacing PartsGeneral Decorative FrameMaIN Burner Glass WindowBlack Enamelled Panels Ensure no stone pebbles fall into the pilot area MaIN Control AssemblyIgnition Lead Pilot Unit AssemblyControl BOX Magnetic safety valveGAS Valve Main injector Pressure and Leak Testing the AppliancePrimary Aeration Plate Changing between Gas TypesComponent ShoRt Spares ListStudio 1 BF Studio 2 BF Service Records Member of the Stovax Group