INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
STUDIO 1 BF: | STUDIO 2 BF: |
8700BFCHEC8701BFCHEC
P8700BFCHECP8701BFCHEC
Model | Gas | Gas | Working | Aeration | Injector | Gas Rate | Input kW (Gross) | Country | |
| CAT. | Type | Pressure |
|
| m3/h |
|
|
|
|
|
|
|
|
|
| High | Low |
|
|
|
|
|
|
|
|
|
|
|
Studio 1 BF | 12H | Natural | 20mbar | 16 x 23 | 400 | 0.600 | 6.3 | 3.0 | GB, IE |
|
| G20 |
|
|
|
|
|
|
|
|
| Propane |
| 14 x 16 (1) |
|
|
|
|
|
Studio 1 BF | 13P | G31 | 37mbar | 16 x 23 (1) | 185 | 0.230 | 6.1 | 3.0 | GB, IE |
|
|
|
|
|
|
|
|
|
|
Studio 2 BF | 12H | Natural | 20nbar | 14 X 16 | 600 | 0.800 | 8.4 | 4.3 | GB, IE |
|
| G20 |
|
|
|
|
|
|
|
|
| Propane |
| 14 x 16 (1) |
|
|
|
|
|
Studio 2 BF | 13P | G31 | 37 mbar | 16 x 23 (1) | 225 | 0.275 | 7.3 | 4.0 | GB, IE |
|
|
|
|
|
|
|
|
|
|
Efficiency Class 2 - 81% / NOx Class 4
Flue Outlet Size Ø 150mm
Flue Inlet Size Ø 100mm
Gas Inlet Connection Size Ø 8mm
RESTRICTOR REQUIREMENT
VERTICAL & HORIZONTAL FLUE
| STUDIO 1 BF |
|
|
| STUDIO 2 BF |
| |
|
|
|
|
|
|
|
|
Vertical Flue Height |
| Horizontal Length | Restrictor | Vertical Flue Height |
| Horizontal Length | Restrictor Size |
|
|
| Size |
|
|
|
|
200mm - 500mm |
| Up to 500mm | No restrictor | 700mm - 1490mm |
| Up to 1000mm | No restrictor |
|
|
|
|
|
|
|
|
500mm - 100mm |
| Up to 1000mm | No restrictor | 1500mm - 2490mm |
| Up to 5000mm | No restrictor |
|
|
|
|
|
|
|
|
1000mm - 1490mm |
| Up to 1000mm | 70mm Ø | 2500mm - 3000mm |
| Up to 5000mm | 75mm Ø |
1500mm - 1990mm |
| Up to 5000mm | 70mm Ø |
|
|
|
|
2000mm - 3000mm |
| Up to 5000mm | 60mm Ø |
|
|
|
|
|
|
|
|
|
|
|
|
|
| TOP EXIT - VERTICAL ONLY INCLUDING OFFSET |
|
| |||
|
|
|
|
|
|
| |
| STUDIO 1 BF |
|
|
| STUDIO 2 BF |
| |
|
|
|
|
| |||
Vertical Flue Height |
| Restrictor Size | Vertical Flue Height |
| Restrictor Size | ||
3000 - 4990mm |
| Ø 52mm | 3000mm - 4990mm |
| Ø 60mm | ||
5000mm - 10,000mm |
| Ø 47mm | 5000mm - 10,000mm |
| Ø 52mm | ||
|
|
|
|
|
|
|
|
8