Home Automation OmniPro II Quick Arm, Bypassing Zones, Restoring Zones, 8 = BYPASS, Auto-Bypass

Page 16
Quick Arm

Quick Arm

For extra convenience, the OmniPro II can be armed by simply pressing the DAY, NIGHT, or AWAY button twice, eliminating the need to enter the code.

To quick arm the system in the Away mode, from the top-level display, press Bypassing Zones AWAY 8 = BYPASSAuto-BypassRestoring Zones AWAY 9 = RESTOREManual background .

The quick arm feature only works if the alarm system is in the Off mode, and if no alarms are sounding. This feature is disabled when the system is shipped. If desired, it can be enabled or disabled at any time - See Set Up Arming, Enable Quick Arm.

Bypassing Zones

8 = BYPASS

You can Bypass a zone that you do not want protected while the system is armed. Bypassing is also the only way that a tamper or panic zone can be disarmed. For example, if there is a liquor closet or gun case on a tamper zone, then you must bypass that zone to gain access to it.

Another reason to Bypass a zone is if the zone is having trouble. If a zone is causing a trouble indication, you can bypass that zone to "cut it out" of the system until repairs are made.

When a zone is bypassed, it is no longer checked for alarms. When you bypass a zone using the console (or over the phone) it will Stay bypassed until you Restore it. The console status display will show that the zone is bypassed only when the security system is disarmed. When the system is armed, it does not display bypassed zones.

To bypass a zone, from the main menu or from the top-level display, press 2 on the console keypad, then 8 for bypass. Enter the zone number followed by the ' # ' key, or use the arrow keys to select the zone. After the zone is entered, you will be prompted to enter your security code. The bottom line will now read "ZONE NAME BYPASSED" to remind you that the zone is bypassed.

If a fire zone is bypassed, the console will continue to beep until that zone is restored - See Restoring Zones.

Auto-Bypass

In order to prevent the alarm from sounding unexpectedly if a window or door is open when the system is armed, the OmniPro II will automatically bypass the zone if it is opened when the system is armed.

Note that there is an exit delay before the system is armed in any mode. The bypass will only take place if the zone is not ready (i.e. open) when the exit delay is over and the system is actually armed.

When a zone is Auto-Bypassed, it will be automatically restored once it is secure (i.e. closed), or the next time you arm or disarm the system. The auto-bypass is recorded in the event log as "ZONE NAME BYPASSED". To prevent any zone from being bypassed unintentionally, you should always look for "SYSTEM OK" on the display before arming and leaving the premises.

The Auto-Bypass feature can be disabled if you do not want the system to automatically bypass open zones. If the auto-bypass feature is disabled, the alarm will sound if a zone not ready (i.e. open) when the system is armed.

NOTE: The Auto-Bypass feature is disabled on UL Listed Installations.

Restoring Zones

9 = RESTORE

Restoring a zone puts it back on active duty in the system. When restored, the Bypassed indication will no longer be displayed on the status line and the zone will be checked for alarms.

To restore a zone, from the top-level display, press 2 on the console keypad, then 9 for restore.

Enter the zone number followed by the ' # ' key, or use the arrow keys to select the zone. Press ' 0 ' as the first key to restore all zones. The 0 = ALL choice is removed once a digit key or the down arrow is pressed. After the zone or all zones is entered, you will be prompted to enter your code. The console will beep and the display will return to the top-level display.

Page 8

Image 16
Contents Control & Security System HOME AUTOMATION, INCDocument Number 20R00-2Rev. January Copyright 2001-2006Home Automation, Inc All Rights ReservedINTRODUCTION OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL SETUP UNDERWRITERS LABORATORIES REQUIREMENTS FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage Underwriters Laboratories UL Listing INTRODUCTIONPage OVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniPro II Maintenance CancelAreas Confirmation BeepSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys PageDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code PagePanic Switches Duress CodeArea Arming Manager CodeGOTO Area PageTesting Your System PageControl Commands CONTROLAbout UPB PageWhen set to UPB, the OmniPro II controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsAbout CentraLite About Lutron RadioRAAbout House Controllers PageAbout ALC AboutHouse Codes ALC Module TypesUnit Numbers OmniPro II Unit NumbersModule / Output Unit Numbers PageConfiguring Lighting Scenes in an HLC Room Scrolling Through NamesControlling Units Controlling a Room of HLC LightingStep OperationControlling CentraLite Units PageControlling ALC or X-10Units Controlling RadioRA UnitsPage Ramp Command ALC Scene Command ComposeControlling Compose Units PageTimed Commands Status of a UnitInternal Flags PageControlling Outputs All On / OffAll Lights On All OffScene Commands Scene Set CommandScene On Command Leviton Scene ControlScene Off Command Setting a Link Lighting ScenesUPB Links Activating and Deactivating LinksExecuting Phantom Buttons Executing CentraLite ScenesENTER BUTTON PHANTOM BUTTON 1 0=OFF 1=ONButtons Temperature ControlLeave for Work Button Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageFreeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature PageTemperature Alarms HumidityOutdoor Temperature Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStatus PageSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINETHROUGH PageShow Events Event LogPage Messages Record Memo MessagePlay Memo Message Clear Text MessagesShow Message Log MessageClear Message Say MessageSend Message Pro-Link SERIAL PORTMSGNAME ENTER MESSAGETELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Page1 - Control 2 - Security3 - Button 4 - AllWhen an HAI Communicating Thermostat is entered When a Programmable Energy Saver PESM is entered6 - Status 7 - EventsWhen the HAI Two-WayAudio Module is being used 8 - MessagePlaying and Recording a Message Paging and Listening9 - Good-Bye Panic Button over the Phone # # # # # #Playing and Recording the Address PageEmergency Dial-Out Digital DialerVoice Dialer How the OmniPro II Voice Dialer WorksPC Access What You Hear - If Your OmniPro II Calls YouEntering the Code PageConnecting to Network via PC Access Built-InEthernet PortOmniPro II Ethernet Connections PageDynamic DNS Local NetworkPage Local / Wide Area Network i.ei.e PageSETUP Set Up CodesAccess Areas Authority LevelSet Up Time Duress CodeTIME PageAdvanced Control Programming ACP 1 = Add Programs2 = Show Programs PageMenu Page3 = Delete All Programs Edit ProgramsPage Times Programs Edit Programs WhenPage Button and Event Programs Control Unit / Switch Press Event ButtonsPage Corresponding Switch Table SwitchOmniPro UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsUPB Link Event Buttons PageAlarm Event Buttons X-10Event ButtonsMiscellaneous Event Buttons PageMessage Event Buttons Pro-Link Switch Press Event Buttons CentraLitePage Program Control Commands Edit Program CommandPage Unit Toggle Command Program Security CommandsProgram Button Commands Program All On / All Off CommandsProgram Video Commands Program Message CommandsProgram Temperature Commands Program Energy CostEdit Program Condition Program Control ConditionsProgram Security Mode Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsPage Set Up Dial Telephone AccessRemote Commands Answer Outside CallDial Out Number Dial Out NumbersDial Order PageSet Up Arming Entry DelayExit Delay Audible Exit DelaySet up Miscellaneous Enable Quick ArmEnable Auto Bypass All On For AlarmEnable Freeze Alarm Flash For AlarmHouse Codes 1-16Format FORMATTime Clocks House Codes 1-16All OnPage Latitude, Longitude, and Time Zone ZONE NAMEDaylight Savings PageController IP Address Controller Port NumberNUMBER DESCRIPTIONEncryption Key Set Up NamesPage Set Up Voice Set Up AddressSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSPage FEDERAL COMMUNICATION COMMISSION NOTICE PageIF YOU HAVE TROUBLE WITH YOUR PHONES CANADIAN INDUSTRY CANADA NOTICEPage OmniPro II Voice Dial-OutPlanner APPENDIX A - DIAL OUT PLANNERPage INSTRUCTIONS TO CALLED PARTY PageAPPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTION CODES CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONNOTES ON CUSTOM PHRASES CODEDESCRIPTION CODEPage NOTE TO INSTALLER HAI New Orleans, LA U S A