Home Automation OmniPro II owner manual Set Up Time, Duress Code, Page

Page 64

The display will show all areas that have been enabled for that user. After the area(s) is/are selected, press the ' # ' key.

CODE 2 AREAS:

 

1 2

0=CLR

You can specify the access (on/off) times for the code; this is, the time periods during which the code is valid.

CODE 2 ON TIME:

8:00 AM MTWTF-- #=CHNG

CODE 2 OFF TIME

5:00 PM MTWTF-- #=CHNG

The times and days are changed by pressing the ' # ' key. Choose the 1 (TIME) key to change the On or Off times. You will be prompted to enter the new time. AM/PM must be specified for the time if the AM/PM format is being used, otherwise the entered time should be 13:00-23:59. Each item defaults to its current value. Press the up arrow key to select Sunrise and press the down arrow key to select Sunset.

CODE 2(ON/OFF)TIME: 1=TIME 2=DAYS

TIME: 8:00 AM

HHMM =RISE/AM =SET/PM

To change days, press the ' # ' key, then press the 2 (DAYS) key. You will be prompted to enter the day(s) that the code will be valid. Press 1-7 for Monday - Sunday, 0 for Never, 8 for Weekdays, and 9 for Weekends.

DAY(S): MTWTFSS

1-7=MON-SUN 0=NEVER

Duress Code

If you are forced to disarm the system against your will by an intruder, disarm it as you normally would, but use the Duress Code instead of your normal code. The system will disarm normally. No sirens will sound, no lights will flash, but the OmniPro II will perform a silent dial out and say that this is a silent alarm.

To stop a silent dial out, turn your security system off by pressing OFF, then your code.

DURESS CODE:

0000-9999 0000=DISABLE

Set Up Time

To set up time and date, from the Setup menu, press the 2 (TIME) key. You will be prompted to enter the new time and date. AM/PM must be specified for the time if that format is being used, otherwise the entered time should be 13:00-23:59.

TIME:

HHMM =AM =PM

DAYLIGHT SAVINGS TIME? 0=NO 1=YES

If Daylight Savings Time is currently being observed (between spring and fall), set this item to "Yes". If Daylight Savings Time is not currently being observed (between fall and spring) or is not observed in your geographic location, set this item to "No". This item is used to correctly calculate the times for sunrise and sunset.

You are only asked this question when you set the time. Once the time is set, OmniPro II will automatically adjust the "time of day" each time daylight savings time begins and ends.

ENTER DATE:

MMDDYY

Page 56

Image 64
Contents Control & Security System HOME AUTOMATION, INCDocument Number 20R00-2Rev. January Copyright 2001-2006Home Automation, Inc All Rights ReservedINTRODUCTION OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL SETUP UNDERWRITERS LABORATORIES REQUIREMENTS FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage Underwriters Laboratories UL Listing INTRODUCTIONPage OVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniPro II Maintenance CancelAreas Confirmation BeepSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys PageDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code PagePanic Switches Duress CodeArea Arming Manager CodeGOTO Area PageTesting Your System PageControl Commands CONTROLAbout UPB PageWhen set to UPB, the OmniPro II controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsAbout CentraLite About Lutron RadioRAAbout House Controllers PageAbout ALC AboutHouse Codes ALC Module TypesUnit Numbers OmniPro II Unit NumbersModule / Output Unit Numbers PageConfiguring Lighting Scenes in an HLC Room Scrolling Through NamesControlling Units Controlling a Room of HLC LightingStep OperationControlling CentraLite Units PageControlling ALC or X-10Units Controlling RadioRA UnitsPage Ramp Command ALC Scene Command ComposeControlling Compose Units PageTimed Commands Status of a UnitInternal Flags PageControlling Outputs All On / OffAll Lights On All OffScene Commands Scene Set CommandScene On Command Leviton Scene ControlScene Off Command Setting a Link Lighting ScenesUPB Links Activating and Deactivating LinksExecuting Phantom Buttons Executing CentraLite ScenesENTER BUTTON PHANTOM BUTTON 1 0=OFF 1=ONButtons Temperature ControlLeave for Work Button Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageFreeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature PageTemperature Alarms HumidityOutdoor Temperature Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStatus PageSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINETHROUGH PageShow Events Event LogPage Messages Record Memo MessagePlay Memo Message Clear Text MessagesShow Message Log MessageClear Message Say MessageSend Message Pro-Link SERIAL PORTMSGNAME ENTER MESSAGETELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Page1 - Control 2 - Security3 - Button 4 - AllWhen an HAI Communicating Thermostat is entered When a Programmable Energy Saver PESM is entered6 - Status 7 - EventsWhen the HAI Two-WayAudio Module is being used 8 - MessagePlaying and Recording a Message Paging and Listening9 - Good-Bye Panic Button over the Phone # # # # # #Playing and Recording the Address PageEmergency Dial-Out Digital DialerVoice Dialer How the OmniPro II Voice Dialer WorksPC Access What You Hear - If Your OmniPro II Calls YouEntering the Code PageConnecting to Network via PC Access Built-InEthernet PortOmniPro II Ethernet Connections PageDynamic DNS Local NetworkPage Local / Wide Area Network i.ei.e PageSETUP Set Up CodesAccess Areas Authority LevelSet Up Time Duress CodeTIME PageAdvanced Control Programming ACP 1 = Add Programs2 = Show Programs PageMenu Page3 = Delete All Programs Edit ProgramsPage Times Programs Edit Programs WhenPage Button and Event Programs Control Unit / Switch Press Event ButtonsPage Corresponding Switch Table SwitchOmniPro UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsUPB Link Event Buttons PageAlarm Event Buttons X-10Event ButtonsMiscellaneous Event Buttons PageMessage Event Buttons Pro-Link Switch Press Event Buttons CentraLitePage Program Control Commands Edit Program CommandPage Unit Toggle Command Program Security CommandsProgram Button Commands Program All On / All Off CommandsProgram Video Commands Program Message CommandsProgram Temperature Commands Program Energy CostEdit Program Condition Program Control ConditionsProgram Security Mode Conditions Program Zone ConditionsProgram Other Conditions Program Time Clock ConditionsPage Set Up Dial Telephone AccessRemote Commands Answer Outside CallDial Out Number Dial Out NumbersDial Order PageSet Up Arming Entry DelayExit Delay Audible Exit DelaySet up Miscellaneous Enable Quick ArmEnable Auto Bypass All On For AlarmEnable Freeze Alarm Flash For AlarmHouse Codes 1-16Format FORMATTime Clocks House Codes 1-16All OnPage Latitude, Longitude, and Time Zone ZONE NAMEDaylight Savings PageController IP Address Controller Port NumberNUMBER DESCRIPTIONEncryption Key Set Up NamesPage Set Up Voice Set Up AddressSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSPage FEDERAL COMMUNICATION COMMISSION NOTICE PageIF YOU HAVE TROUBLE WITH YOUR PHONES CANADIAN INDUSTRY CANADA NOTICEPage OmniPro II Voice Dial-OutPlanner APPENDIX A - DIAL OUT PLANNERPage INSTRUCTIONS TO CALLED PARTY PageAPPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTION CODES CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONNOTES ON CUSTOM PHRASES CODEDESCRIPTION CODEPage NOTE TO INSTALLER HAI New Orleans, LA U S A