UNDERWRITER'S LABORATORIES REQUIREMENTS

For a complete list of requirements and restrictions when installing the OmniPro II panel in a UL Listed system, refer to the Underwriter's Laboratories Requirements section of the Installation Manual (10I00-2).

When used in UL Listed Installations, the following items apply:

1.The "High Security Mode" must be ON.

2.The "Enable Auto Bypass" feature must be OFF.

3.The ENTRY DELAY shall not exceed 45 seconds for residential applications; 60 seconds for commercial applications.

4.The EXIT DELAY shall not exceed 60 seconds.

5.Double Delay and Quad Delay zone types shall not be used.

6.For residential applications the sounding device may be mounted indoors. If, however, the sounding device is connected to the "EXT HORN" terminals of the OmniPro II, then the "OUTSIDE SIREN DELAY" shall be set to 0.

7.The DIAL OUT DELAY shall not exceed 30 seconds.

8.The BEEP ON TROUBLE feature must be ON, and CONSOLE SOUNDER must be ON.

Installer:

NAME: __________________________________

NUMBER: _______________________________

FIRE ESCAPE PLANNING

Your fire protection system is designed to provide warning in the event of a fire. It is your responsibility to plan your escape routes in the event of a fire alarm. Your family should practice "fire drills" periodically to ensure that everyone is familiar with the plan.

1.Draw a floor plan of your home, showing location of fire and smoke detectors. Show two exit routes from each room: The primary exit and an alternate escape route.

2.Be sure that your family knows what the fire alarm signal sounds like.

3.In the event of a fire alarm, DO NOT open a closed door. First, touch the door. If it is hot to the touch, use the alternative escape route.

4.Since smoke tends to rise, keep low to the floor during your escape, crawling if necessary. If you encounter any smoke, hold your breath.

5.During a fire alarm, do not stop to pack or gather belongings. Exit immediately and meet at a designated spot outside the house.

6.DO NOT return to a burning house.

7.Notify the fire department using a neighbor's telephone.

8.Review your escape plan and rehearse a fire alarm periodically with your family.

Page 81

Image 89
Contents Document Number 20R00-2Rev. January HOME AUTOMATION, INCControl & Security System All Rights Reserved Copyright 2001-2006Home Automation, IncOVERALL DESCRIPTION INTRODUCTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL SETUP FEDERAL COMMUNICATION COMMISSION NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSCANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage Page INTRODUCTIONUnderwriters Laboratories UL Listing Console Operation OVERALL DESCRIPTION1- OFF 2- DAYDisplay Menus Normal Top-LevelDisplay6- UP ARROW 7- CONSOLE LEDMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel OmniPro II MaintenanceAreas Confirmation BeepArming the Security System SECURITY SYSTEM OPERATION0 = OFF 1 = DAY2 = NIGHT Using Shortcut Keys3 = AWAY 4 = VACATIONQuick Arm 9 = RESTOREBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated #=GOTOGas Alarm Activated Fire Alarm ActivatedEmergency Keys PageAlarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Police EmergencyCodes Trouble IndicationsMaster Code PageDuress Code Panic SwitchesArea Arming Manager CodePage GOTO AreaPage Testing Your SystemCONTROL Control CommandsAbout UPB PageRoom Controller LED Indicators When set to UPB, the OmniPro II controller canHAI Lighting Control HLC Format About RoomsAbout Lutron RadioRA About CentraLiteAbout House Controllers PageAbout About ALCHouse Codes ALC Module TypesOmniPro II Unit Numbers Unit NumbersModule / Output Unit Numbers PageScrolling Through Names Configuring Lighting Scenes in an HLC RoomControlling Units Controlling a Room of HLC LightingOperation StepControlling CentraLite Units PagePage Controlling RadioRA UnitsControlling ALC or X-10Units Scene Command Compose Ramp Command ALCControlling Compose Units PageStatus of a Unit Timed CommandsInternal Flags PageAll On / Off Controlling OutputsAll Lights On All OffScene Set Command Scene CommandsScene On Command Leviton Scene ControlSetting a Link Lighting Scenes Scene Off CommandUPB Links Activating and Deactivating LinksExecuting CentraLite Scenes Executing Phantom ButtonsENTER BUTTON PHANTOM BUTTON 1 0=OFF 1=ONTemperature Control ButtonsLeave for Work Button Dinner for Two ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsIMPORTANT NOTES Freeze AlarmsIndoor and Outdoor Temperature PageHumidity Temperature AlarmsOutdoor Temperature Temperature Control of AppliancesConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStatus PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationOFFHK - OFF HOOK ONHK - ON HOOKRING - RINGING DEAD - DEAD PHONE LINEPage THROUGHPage Event LogShow Events Record Memo Message MessagesPlay Memo Message Clear Text MessagesLog Message Show MessageClear Message Say MessageSERIAL PORT Send Message Pro-LinkMSGNAME ENTER MESSAGETelephone Interface TELEPHONE CONTROLIn-HousePhones Remote PhonesAlternate Method Phone Access Denied - Remote LockoutMain Menu Page2 - Security 1 - Control3 - Button 4 - AllWhen a Programmable Energy Saver PESM is entered When an HAI Communicating Thermostat is entered6 - Status 7 - Events8 - Message When the HAI Two-WayAudio Module is being usedPlaying and Recording a Message Paging and ListeningPanic Button over the Phone # # # # # # 9 - Good-ByePlaying and Recording the Address PageDigital Dialer Emergency Dial-OutVoice Dialer How the OmniPro II Voice Dialer WorksWhat You Hear - If Your OmniPro II Calls You PC AccessEntering the Code PageBuilt-InEthernet Port Connecting to Network via PC AccessOmniPro II Ethernet Connections PagePage Local NetworkDynamic DNS i.e Local / Wide Area Networki.e PageSet Up Codes SETUPAccess Areas Authority LevelDuress Code Set Up TimeTIME Page1 = Add Programs Advanced Control Programming ACP2 = Show Programs PagePage MenuPage Edit Programs3 = Delete All Programs Page Edit Programs WhenTimes Programs Page Control Unit / Switch Press Event ButtonsButton and Event Programs Switch Corresponding Switch TableOmniPro UPB 6-ButtonKeypadAll On/Off Event Buttons Zone Event ButtonsUPB Link Event Buttons PageX-10Event Buttons Alarm Event ButtonsMiscellaneous Event Buttons PagePage Switch Press Event Buttons CentraLiteMessage Event Buttons Pro-Link Page Edit Program CommandProgram Control Commands Program Security Commands Unit Toggle CommandProgram Button Commands Program All On / All Off CommandsProgram Message Commands Program Video CommandsProgram Temperature Commands Program Energy CostProgram Control Conditions Edit Program ConditionProgram Security Mode Conditions Program Zone ConditionsPage Program Time Clock ConditionsProgram Other Conditions Telephone Access Set Up DialRemote Commands Answer Outside CallDial Out Numbers Dial Out NumberDial Order PageEntry Delay Set Up ArmingExit Delay Audible Exit DelayEnable Quick Arm Set up MiscellaneousEnable Auto Bypass All On For AlarmFlash For Alarm Enable Freeze AlarmHouse Codes 1-16Format FORMATPage House Codes 1-16All OnTime Clocks ZONE NAME Latitude, Longitude, and Time ZoneDaylight Savings PageController Port Number Controller IP AddressNUMBER DESCRIPTIONPage Set Up NamesEncryption Key Set Up Address Set Up VoiceSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑Page UNDERWRITERS LABORATORIES REQUIREMENTSFIRE ESCAPE PLANNING Page FEDERAL COMMUNICATION COMMISSION NOTICEPage CANADIAN INDUSTRY CANADA NOTICEIF YOU HAVE TROUBLE WITH YOUR PHONES Page APPENDIX A - DIAL OUT PLANNEROmniPro II Voice Dial-OutPlanner Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTIONDESCRIPTION CODECODE DESCRIPTIONCODE NOTES ON CUSTOM PHRASESDESCRIPTION CODEPage HAI New Orleans, LA U S A NOTE TO INSTALLER