Manager Code

The Manager codes can arm/disarm the security system in assigned areas, during assigned times. The Manager code can access functions that are code protected in High Security mode. Managers may also access the system from an outside telephone line.

User Code

User codes can only be used to arm and disarm the security system in assigned areas when the time assigned to that code is valid.

Duress Code

If you are forced to disarm the system against your will by an intruder, disarm it as you normally would, but use the Duress Code instead of your normal code. The system will disarm normally. No sirens will sound, no lights will flash, but the OmniPro II will perform a silent dial out and say that this is a silent alarm.

To stop a silent dial out, turn your security system off the usual way, pressing Off key, then your code.

Panic Switches

If you have had panic switches installed, they are always armed. Pressing a panic switch will cause the alarm to activate. This alarm can only be silenced by pressing the Off key and a valid code on the console.

Area Arming

If your installer has enabled the Area feature, the security system may be armed in Area 1, and disarmed in Area 2. In fact, each area may be armed in different security modes at the same time. Each area will have its own console that will control that area independently from the other.

When disarming the security system or arming the security system in any mode, the system will automatically control all security functions in the area of that console if your code is valid for that area.

If you have a Master code, your code is valid in any area. If you are in Area 2, and wanted to arm the system in the Away mode, simply press the Away key and enter your code. The system will automatically arm Area 2. The security mode in Area 1 will not change.

If you have a code that is only valid in Area 1, you will not be able to disarm or arm Area 2.

If you are in Area 1 and wish to disarm the security system in Area 2, OmniPro II will allow you to disarm Area 2 from the console in Area 1 if you have a Master code or a code that is valid for both areas.

From the top-level display or from the main menu, press the 2 (SEC) key on the console keypad.

Press the 0 (OFF) key, the display will show:

 

DISARM

 

ENTER CODE:

#=AREA

Press the ' # ' (AREA) key, the display will show:

 

AREA:

0=ALL

ENTER AREA

The Area number can be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of areas. If the ' 0 ' key is pressed, then all areas will be selected.

Press the 2 key then the ' # ' key. You will then be prompted to enter your code. The display will show:

DISARM AREA 2

ENTER CODE:

Page 13

Image 21
Contents HOME AUTOMATION, INC Control & Security SystemDocument Number 20R00-2Rev. January All Rights Reserved Copyright 2001-2006Home Automation, IncOVERALL DESCRIPTION INTRODUCTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL SETUP FEDERAL COMMUNICATION COMMISSION NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSCANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage INTRODUCTION Underwriters Laboratories UL ListingPage Console Operation OVERALL DESCRIPTION1- OFF 2- DAYDisplay Menus Normal Top-LevelDisplay6- UP ARROW 7- CONSOLE LEDMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel OmniPro II MaintenanceAreas Confirmation BeepArming the Security System SECURITY SYSTEM OPERATION0 = OFF 1 = DAY2 = NIGHT Using Shortcut Keys3 = AWAY 4 = VACATIONQuick Arm 9 = RESTOREBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated #=GOTOGas Alarm Activated Fire Alarm ActivatedEmergency Keys PageAlarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Police EmergencyCodes Trouble IndicationsMaster Code PageDuress Code Panic SwitchesArea Arming Manager CodePage GOTO AreaPage Testing Your SystemCONTROL Control CommandsAbout UPB PageRoom Controller LED Indicators When set to UPB, the OmniPro II controller canHAI Lighting Control HLC Format About RoomsAbout Lutron RadioRA About CentraLiteAbout House Controllers PageAbout About ALCHouse Codes ALC Module TypesOmniPro II Unit Numbers Unit NumbersModule / Output Unit Numbers PageScrolling Through Names Configuring Lighting Scenes in an HLC RoomControlling Units Controlling a Room of HLC LightingOperation StepControlling CentraLite Units PageControlling RadioRA Units Controlling ALC or X-10UnitsPage Scene Command Compose Ramp Command ALCControlling Compose Units PageStatus of a Unit Timed CommandsInternal Flags PageAll On / Off Controlling OutputsAll Lights On All OffScene Set Command Scene CommandsScene On Command Leviton Scene ControlSetting a Link Lighting Scenes Scene Off CommandUPB Links Activating and Deactivating LinksExecuting CentraLite Scenes Executing Phantom ButtonsENTER BUTTON PHANTOM BUTTON 1 0=OFF 1=ONTemperature Control ButtonsLeave for Work Button Dinner for Two ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsIMPORTANT NOTES Freeze AlarmsIndoor and Outdoor Temperature PageHumidity Temperature AlarmsOutdoor Temperature Temperature Control of AppliancesConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStatus PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationOFFHK - OFF HOOK ONHK - ON HOOKRING - RINGING DEAD - DEAD PHONE LINEPage THROUGHEvent Log Show EventsPage Record Memo Message MessagesPlay Memo Message Clear Text MessagesLog Message Show MessageClear Message Say MessageSERIAL PORT Send Message Pro-LinkMSGNAME ENTER MESSAGETelephone Interface TELEPHONE CONTROLIn-HousePhones Remote PhonesAlternate Method Phone Access Denied - Remote LockoutMain Menu Page2 - Security 1 - Control3 - Button 4 - AllWhen a Programmable Energy Saver PESM is entered When an HAI Communicating Thermostat is entered6 - Status 7 - Events8 - Message When the HAI Two-WayAudio Module is being usedPlaying and Recording a Message Paging and ListeningPanic Button over the Phone # # # # # # 9 - Good-ByePlaying and Recording the Address PageDigital Dialer Emergency Dial-OutVoice Dialer How the OmniPro II Voice Dialer WorksWhat You Hear - If Your OmniPro II Calls You PC AccessEntering the Code PageBuilt-InEthernet Port Connecting to Network via PC AccessOmniPro II Ethernet Connections PageLocal Network Dynamic DNSPage i.e Local / Wide Area Networki.e PageSet Up Codes SETUPAccess Areas Authority LevelDuress Code Set Up TimeTIME Page1 = Add Programs Advanced Control Programming ACP2 = Show Programs PagePage MenuEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage Switch Corresponding Switch TableOmniPro UPB 6-ButtonKeypadAll On/Off Event Buttons Zone Event ButtonsUPB Link Event Buttons PageX-10Event Buttons Alarm Event ButtonsMiscellaneous Event Buttons PageSwitch Press Event Buttons CentraLite Message Event Buttons Pro-LinkPage Edit Program Command Program Control CommandsPage Program Security Commands Unit Toggle CommandProgram Button Commands Program All On / All Off CommandsProgram Message Commands Program Video CommandsProgram Temperature Commands Program Energy CostProgram Control Conditions Edit Program ConditionProgram Security Mode Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsPage Telephone Access Set Up DialRemote Commands Answer Outside CallDial Out Numbers Dial Out NumberDial Order PageEntry Delay Set Up ArmingExit Delay Audible Exit DelayEnable Quick Arm Set up MiscellaneousEnable Auto Bypass All On For AlarmFlash For Alarm Enable Freeze AlarmHouse Codes 1-16Format FORMATHouse Codes 1-16All On Time ClocksPage ZONE NAME Latitude, Longitude, and Time ZoneDaylight Savings PageController Port Number Controller IP AddressNUMBER DESCRIPTIONSet Up Names Encryption KeyPage Set Up Address Set Up VoiceSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage Page FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER OmniPro II Voice Dial-OutPlannerPage Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTIONDESCRIPTION CODECODE DESCRIPTIONCODE NOTES ON CUSTOM PHRASESDESCRIPTION CODEPage HAI New Orleans, LA U S A NOTE TO INSTALLER