Scene Off Command

Once the Scenes have been sent, press the 0 (OFF) key to command the four units in that Scene to turn off.

Notes:

1.When sending Scene Commands, the controller must be configured to allow Extended Code transmissions on each House Code affected by a Scene.

2.The Scene Commands always apply to a group of four consecutive units, which are units 1-4, 5-8, 9-12, and 13-16 on a particular house code. You must address the units accordingly so that the desired units fall into the appropriate lighting groups.

3.The actual Extended Code Scene commands use a "group reference" that matches that sent by a Leviton Wall-Mounted Scene Controller set to the same address as the first unit in the lighting group. This allows wall-mounted controllers to be easily used for manual Scene selection.

UPB Links

In a UPB network, all control operations are done using Links. OmniPro II can transmit and receive up to 250 Links on the UPB network. Links are used to logically “connect” events on one or more devices to actions on one or more other devices. When two or more different devices share a common Link, they are said to be “linked” together. They can now communicate with each other over the powerline using the Link as a common identifier in all of their communications.

The power of Links is that you can “link” more than two devices together. For example, one keypad controller pushbutton can be linked to four UPB Wall Switches allowing the single press of that pushbutton to trigger all four lights to go to preset or absolute levels. In addition UPB Wall Switches allow for a preset light level and fade rate to be associated with each Link.

Activating and Deactivating Links

A special UPB command called “Link On” (activate) is used to command all of the devices that have the same Link to go to their preset light levels at their preset fade rates.

For instance, in our “All On” and “All Off” example, when “Link 50 On” is transmitted by OmniPro II, each UPB Wall Switch with Link 50 will go to 100% to achieve the “All On” effect. Other “Link On” (activate) commands may be transmitted that cause Wall Switch ‘1’ to go to a desired level at a specified fade rate and Wall Switch ‘2’ to go to a different level at a different fade rate. The ability to send more than one device to its preset level at a preset fade rate with a single command is known as activating a Link. Likewise, pressing a pushbutton on a 6-Button or 8-Button Keypad can send the “Link On” (activate) command.

A special UPB command called “Link Off” (deactivate) is used to command all of the devices that have the same Link to go to 0% at their preset fade rate. For instance, in our “All On” and “All Off” example, when “Link 50 Off” is transmitted by OmniPro II, each Wall Switch with Link 50 will go to 0% to achieve the “All Off” effect.

Setting a Link (Lighting Scenes)

Lighting scenes are created by pre-configuring light levels and fade rates in one or more UPB devices that get “activated” and “deactivated” by a Link command or button press on a 6-Button or 8-Button Keypad.

Each UPB Wall Switch can hold up to sixteen different preset light levels (0% - 100%) that can be “linked” to the OmniPro II controller or to a pushbutton on a 6-Button or 8-Button Keypad.

OmniPro II can “set” each of the 250 possible Links. The “Link Set” command is used to set up lighting scenes for a lighting group. To set a “lighting scene” using OmniPro II, adjust all of the UPB Wall Switches with the pre-configured Link to the desired lighting levels. The desired lighting levels may be set manually at the switch, or by a command issued from OmniPro II. After the desired lighting levels are set, the “Link Set” command can be transmitted by OmniPro II to save the new “light levels” for each of the devices pre-configured with the specified Link.

Page 28

Image 36
Contents HOME AUTOMATION, INC Control & Security SystemDocument Number 20R00-2Rev. January Copyright 2001-2006Home Automation, Inc All Rights ReservedINTRODUCTION OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL SETUP UNDERWRITERS LABORATORIES REQUIREMENTS FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage INTRODUCTION Underwriters Laboratories UL ListingPage OVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmniPro II Maintenance CancelAreas Confirmation BeepSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys PageDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code PagePanic Switches Duress CodeArea Arming Manager CodeGOTO Area PageTesting Your System PageControl Commands CONTROLAbout UPB PageWhen set to UPB, the OmniPro II controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsAbout CentraLite About Lutron RadioRAAbout House Controllers PageAbout ALC AboutHouse Codes ALC Module TypesUnit Numbers OmniPro II Unit NumbersModule / Output Unit Numbers PageConfiguring Lighting Scenes in an HLC Room Scrolling Through NamesControlling Units Controlling a Room of HLC LightingStep OperationControlling CentraLite Units PageControlling RadioRA Units Controlling ALC or X-10UnitsPage Ramp Command ALC Scene Command ComposeControlling Compose Units PageTimed Commands Status of a UnitInternal Flags PageControlling Outputs All On / OffAll Lights On All OffScene Commands Scene Set CommandScene On Command Leviton Scene ControlScene Off Command Setting a Link Lighting ScenesUPB Links Activating and Deactivating LinksExecuting Phantom Buttons Executing CentraLite ScenesENTER BUTTON PHANTOM BUTTON 1 0=OFF 1=ONButtons Temperature ControlLeave for Work Button Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageFreeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature PageTemperature Alarms HumidityOutdoor Temperature Temperature Control of AppliancesConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStatus PageSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINETHROUGH PageEvent Log Show EventsPage Messages Record Memo MessagePlay Memo Message Clear Text MessagesShow Message Log MessageClear Message Say MessageSend Message Pro-Link SERIAL PORTMSGNAME ENTER MESSAGETELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Page1 - Control 2 - Security3 - Button 4 - AllWhen an HAI Communicating Thermostat is entered When a Programmable Energy Saver PESM is entered6 - Status 7 - EventsWhen the HAI Two-WayAudio Module is being used 8 - MessagePlaying and Recording a Message Paging and Listening9 - Good-Bye Panic Button over the Phone # # # # # #Playing and Recording the Address PageEmergency Dial-Out Digital DialerVoice Dialer How the OmniPro II Voice Dialer WorksPC Access What You Hear - If Your OmniPro II Calls YouEntering the Code PageConnecting to Network via PC Access Built-InEthernet PortOmniPro II Ethernet Connections PageLocal Network Dynamic DNSPage Local / Wide Area Network i.ei.e PageSETUP Set Up CodesAccess Areas Authority LevelSet Up Time Duress CodeTIME PageAdvanced Control Programming ACP 1 = Add Programs2 = Show Programs PageMenu PageEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage Corresponding Switch Table SwitchOmniPro UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsUPB Link Event Buttons PageAlarm Event Buttons X-10Event ButtonsMiscellaneous Event Buttons PageSwitch Press Event Buttons CentraLite Message Event Buttons Pro-LinkPage Edit Program Command Program Control CommandsPage Unit Toggle Command Program Security CommandsProgram Button Commands Program All On / All Off CommandsProgram Video Commands Program Message CommandsProgram Temperature Commands Program Energy CostEdit Program Condition Program Control ConditionsProgram Security Mode Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsPage Set Up Dial Telephone AccessRemote Commands Answer Outside CallDial Out Number Dial Out NumbersDial Order PageSet Up Arming Entry DelayExit Delay Audible Exit DelaySet up Miscellaneous Enable Quick ArmEnable Auto Bypass All On For AlarmEnable Freeze Alarm Flash For AlarmHouse Codes 1-16Format FORMATHouse Codes 1-16All On Time ClocksPage Latitude, Longitude, and Time Zone ZONE NAMEDaylight Savings PageController IP Address Controller Port NumberNUMBER DESCRIPTIONSet Up Names Encryption KeyPage Set Up Voice Set Up AddressSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage FEDERAL COMMUNICATION COMMISSION NOTICE PageCANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER OmniPro II Voice Dial-OutPlannerPage INSTRUCTIONS TO CALLED PARTY PageAPPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTION CODES CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONNOTES ON CUSTOM PHRASES CODEDESCRIPTION CODEPage NOTE TO INSTALLER HAI New Orleans, LA U S A