Home Automation OmniPro II Set Up Dial, Telephone Access, Answer Outside Call, Remote Commands

Page 79

Set Up Dial

The Set Up Dial menu is used to configure all of the telephone related items for the OmniPro II. To enter the Set Up Dial menu, from the Setup menu, press the 4 (DIAL) key. Use the arrows to scroll through the items. For each item, the top line displays a description of the item and its current setting. The bottom line shows the available ranges for your selections.

Phone numbers can be up to 24 characters long. The number is shown on the bottom line of the display. Press the OFF key to enter a ' - ' into the number. Press the DAY key to specify a pause of 2 seconds (shown as a "T" on the display). Press the NIGHT key to enter a ' # ' into the number. Enter a single ' - ' for no number.

Telephone Access

The Telephone Access item allows you to turn the local (in-house) and remote telephone control feature on and off.

If set to On, the OmniPro II will allow local and remote telephone access as described in Telephone Control. If set to Off, the OmniPro II will not answer incoming calls ever, and will not work on the in house phones. Dial outs will still occur, and the system will operate normally when the OmniPro II dials out.

If you do not have your OmniPro II connected to a phone line, set Telephone Access to Off to keep the system from displaying "PHONE LINE DEAD". The default setting for Telephone Access is On.

Answer Outside Call

If you do not want your system to Answer Outside Call, set this item to No. The local (in-house) telephone control features will still work, but the system will never answer an incoming call.

The default setting for Answer Outside Call is Yes.

Remote Commands

The Remote Commands Ok item allows you to prevent any commands from being issued from a remote telephone.

If Remote Commands Ok is set to Yes, the OmniPro II will allow all commands to be executed when called from a remote telephone. If Remote Commands Ok is set to No, then lights, appliances, and the security system cannot be controlled from a remote telephone that dials into your home.

You can issue commands from a local (in-house) phone with Remote Commands Ok set to Yes or No. The default setting is Yes.

Rings Before Answer

Your phone must ring this number of times before the OmniPro II will answer an incoming call to your phone.

To change Rings Before Answer, enter the new number from 1 to 15, then press the ' # ' key. The factory default setting is 8.

Dial Type

The Dial Type specifies the type of dialing used when the OmniPro II dials out. If you do not have Touch-Tone service, then Dial Type must be set to Pulse.

The default Dial Type is Tone.

My Phone Number

My Phone Number is the phone number that will be announced when the OmniPro II dials out in the event of an alarm. It should be set to the phone number of the premises where your system is installed.

To enter phone numbers, press the keypad keys 0 - 9. You can put in a dash (-) for legibility by pressing the Off key.

Press the ' # ' key after you have pressed all of the digits in the phone number. For example, to enter the number 555-1234, press 555 "OFF" 1234 #.

Page 71

Image 79
Contents Control & Security System HOME AUTOMATION, INCDocument Number 20R00-2Rev. January All Rights Reserved Copyright 2001-2006Home Automation, IncContents INTRODUCTIONOVERALL DESCRIPTION SECURITY SYSTEM OPERATIONCONTROL TELEPHONE CONTROL SETUP APPENDIX A - DIAL OUT PLANNER UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE CANADIAN INDUSTRY CANADA NOTICEPage Underwriters Laboratories UL Listing INTRODUCTIONPage 2- DAY OVERALL DESCRIPTIONConsole Operation 1- OFF7- CONSOLE LED Normal Top-LevelDisplayDisplay Menus 6- UP ARROWTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsConfirmation Beep OmniPro II MaintenanceCancel Areas1 = DAY SECURITY SYSTEM OPERATIONArming the Security System 0 = OFF4 = VACATION Using Shortcut Keys2 = NIGHT 3 = AWAYRestoring Zones 9 = RESTOREQuick Arm Bypassing Zones#=GOTO What To Do When You Come HomeWhat Happens When the Alarm is Activated Burglar Alarm ActivatedPage Fire Alarm ActivatedGas Alarm Activated Emergency KeysPolice Emergency Duress Code Entered or Duress Alarm ActivatedAlarm Reset Alarm CancelPage Trouble IndicationsCodes Master CodeManager Code Panic SwitchesDuress Code Area ArmingPage GOTO AreaPage Testing Your SystemPage Control CommandsCONTROL About UPBAbout Rooms When set to UPB, the OmniPro II controller canRoom Controller LED Indicators HAI Lighting Control HLC FormatPage About CentraLiteAbout Lutron RadioRA About House ControllersALC Module Types About ALCAbout House CodesPage Unit NumbersOmniPro II Unit Numbers Module / Output Unit NumbersControlling a Room of HLC Lighting Configuring Lighting Scenes in an HLC RoomScrolling Through Names Controlling UnitsPage StepOperation Controlling CentraLite UnitsControlling ALC or X-10Units Controlling RadioRA UnitsPage Page Ramp Command ALCScene Command Compose Controlling Compose UnitsPage Timed CommandsStatus of a Unit Internal FlagsAll Off Controlling OutputsAll On / Off All Lights OnLeviton Scene Control Scene CommandsScene Set Command Scene On CommandActivating and Deactivating Links Scene Off CommandSetting a Link Lighting Scenes UPB LinksPHANTOM BUTTON 1 0=OFF 1=ON Executing Phantom ButtonsExecuting CentraLite Scenes ENTER BUTTONDinner for Two Button ButtonsTemperature Control Leave for Work ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsPage Freeze AlarmsIMPORTANT NOTES Indoor and Outdoor TemperatureTemperature Control of Appliances Temperature AlarmsHumidity Outdoor TemperaturePage Configuring HLC DevicesConfiguring HLC Devices using an Omni Console StatusStep Operation Setup Mode for HLC DevicesStep Operation Step OperationDEAD - DEAD PHONE LINE ONHK - ON HOOKOFFHK - OFF HOOK RING - RINGINGPage THROUGHShow Events Event LogPage Clear Text Messages MessagesRecord Memo Message Play Memo MessageSay Message Show MessageLog Message Clear MessageENTER MESSAGE Send Message Pro-LinkSERIAL PORT MSGNAMERemote Phones TELEPHONE CONTROLTelephone Interface In-HousePhonesPage Phone Access Denied - Remote LockoutAlternate Method Main Menu4 - All 1 - Control2 - Security 3 - Button7 - Events When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 6 - StatusPaging and Listening When the HAI Two-WayAudio Module is being used8 - Message Playing and Recording a MessagePage 9 - Good-ByePanic Button over the Phone # # # # # # Playing and Recording the AddressHow the OmniPro II Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerPage PC AccessWhat You Hear - If Your OmniPro II Calls You Entering the CodePage Connecting to Network via PC AccessBuilt-InEthernet Port OmniPro II Ethernet ConnectionsDynamic DNS Local NetworkPage Page Local / Wide Area Networki.e i.eAuthority Level SETUPSet Up Codes Access AreasPage Set Up TimeDuress Code TIMEPage Advanced Control Programming ACP1 = Add Programs 2 = Show ProgramsPage Menu3 = Delete All Programs Edit ProgramsPage Times Programs Edit Programs WhenPage Button and Event Programs Control Unit / Switch Press Event ButtonsPage UPB 6-ButtonKeypad Corresponding Switch TableSwitch OmniProPage Zone Event ButtonsAll On/Off Event Buttons UPB Link Event ButtonsPage Alarm Event ButtonsX-10Event Buttons Miscellaneous Event ButtonsMessage Event Buttons Pro-Link Switch Press Event Buttons CentraLitePage Program Control Commands Edit Program CommandPage Program All On / All Off Commands Unit Toggle CommandProgram Security Commands Program Button CommandsProgram Energy Cost Program Video CommandsProgram Message Commands Program Temperature CommandsProgram Zone Conditions Edit Program ConditionProgram Control Conditions Program Security Mode ConditionsProgram Other Conditions Program Time Clock ConditionsPage Answer Outside Call Set Up DialTelephone Access Remote CommandsPage Dial Out NumberDial Out Numbers Dial OrderAudible Exit Delay Set Up ArmingEntry Delay Exit DelayAll On For Alarm Set up MiscellaneousEnable Quick Arm Enable Auto BypassFORMAT Enable Freeze AlarmFlash For Alarm House Codes 1-16FormatTime Clocks House Codes 1-16All OnPage Page Latitude, Longitude, and Time ZoneZONE NAME Daylight SavingsDESCRIPTION Controller IP AddressController Port Number NUMBEREncryption Key Set Up NamesPage 4=CODE 5=TEMP 6=AREA 8=MSG↑ Set Up VoiceSet Up Address SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSPage Page FEDERAL COMMUNICATION COMMISSION NOTICEIF YOU HAVE TROUBLE WITH YOUR PHONES CANADIAN INDUSTRY CANADA NOTICEPage OmniPro II Voice Dial-OutPlanner APPENDIX A - DIAL OUT PLANNERPage Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESCODE DESCRIPTIONDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODECODE NOTES ON CUSTOM PHRASESCODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER